International travels and fever screening during epidemics: a literature review on the effectiveness and potential use of non-contact infrared thermometers
Open accessThe DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.
Abstract
Several countries plan to introduce non-contact infrared thermometers (NCIT) at international airports in order to detect febrile passengers, thus to delay the introduction of a novel influenza strain. We reviewed the existing studies on fever screening by NCIT to estimate their efficacy under the hypothesis of pandemic influenza. Three Severe Acute Respiratory Syndrome (SARS) or dengue fever interventions in airports were excluded because of insufficient information. Six fever screening studies in other gathering areas, mainly hospitals, were included (N= 176 to 72,327 persons; fever prevalence= 1.2% to 16.9%). Sensitivity varied from 4.0% to 89.6%, specificity from 75.4% to 99.6%, positive predictive value (PPV) from 0.9% to 76.0% and negative predictive value (NPV) from 86.1% to 99.7%. When we fixed fever prevalence at 1% in all studies to allow comparisons, the derived PPV varied from 3.5% to 65.4% and NPV was >=99%. The low PPV suggests limited efficacy of NCIT to detect symptomatic passengers at the early stages of a pandemic influenza, when fever prevalence among passengers would be =<1%. External factors can also impair the screening strategy: passengers can hide their symptoms or cross borders before symptoms occur. These limits should be considered when setting up border control measures to delay the pandemic progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Overall, previous studies using clinical data from hospitals and transit centers have been inconclusive regarding the use and effectiveness of NCITs as a screening method during SARS and influenza outbreaks.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Bitar et al.11 in a similar clinical study reported the sensitivity of NCITs to vary widely from approximately 4–90%.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [11]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling strategies for controlling SARS outbreaks
Gumel, A. B., Ruan, S., Day, T., Watmough, J., Brauer, F., van den Driessche, P., Gabrielson, D., Bowman, C., Alexander, M. E., Ardal, S., et al. (2004) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2004.2800 · Cited by 397
Nonpharmaceutical Interventions for Pandemic Influenza, International Measures
World Health Organization Writing Group (2006) · Emerging Infectious Diseases · doi:10.3201/eid1201.051370 · Cited by 326
Delaying the International Spread of Pandemic Influenza
Cooper, B. S., Pitman, R. J., Edmunds, W. J., & Gay, N. J. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030212 · Cited by 305
A perspective on medical infrared imaging
Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y. (2005) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331333158 · Cited by 283 · cited 9×
“While ribavirin has been shown to be effective in early-stage arenavirus infections, particularly Lassa virus [ 2 ], in the absence of proven effectiveness for prophylaxis [3], oral ribavirin was not recommended for persons who might have been exposed to the case described here.”
BackgroundMethodInfluentialPublic health interventions and SARS spread, 2003
Bell, D. M., & World Health Organization Working Group on Prevention of International and Community Transmission of SARS (2004) · Emerging Infectious Diseases · doi:10.3201/eid1011.040729 · Cited by 272
Will travel restrictions control the international spread of pandemic influenza?
Hollingsworth, T. D., Ferguson, N. M., & Anderson, R. M. (2006) · Nature Medicine · doi:10.1038/nm0506-497 · Cited by 218 · cited 1×
“Modelling works show that border control strategies aimed at reducing the risk of introduction of SARS or influenza in a country have poor sensitivity [17] and limited impact [ 18-21 ].”
BackgroundAnalysis of IR thermal imager for mass blind fever screening
Ng, E. Y. K., Kawb, G. J. L., & Chang, W. M. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.05.003 · Cited by 182 · cited 6×
“Finally, environmental factors can also affect the measurements [2, 10 ], such as the subjectsensor distance, the ambient temperature or humidity and the surrounding ventilation systems, as well as the fact that the person tested should remain immobile for a few seconds in front of the”
BackgroundMethodInfluentialInfrared Thermography to Mass-Screen Suspected Sars Patients with Fever
Chiu, W., Lin, P., Chiou, H. Y., Lee, W. S., Lee, C. N., Yang, Y. Y., Lee, H. M., Hsieh, M. S., Hu, C., Ho, Y. S., et al. (2005) · Asia Pacific Journal of Public Health · doi:10.1177/101053950501700107 · Cited by 111 · cited 3×
“These selected studies summarised in Table 1, included: one in Singapore [10], two in Hong Kong [11,12], two in Taiwan [ 13 ,14] and finally one in France [15].”
BackgroundMethodInfluentialScreening for Fever by Remote-sensing Infrared Thermographic Camera
Chan, L., Cheung, G. T. Y., Lauder, I. J., & Kumana, C. R. (2006) · Journal of Travel Medicine · doi:10.2310/7060.2004.19102 · Cited by 109
SARS in Singapore – Key Lessons from an Epidemic
Tan, C.-C. (2006) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v35n5p345 · Cited by 102
Research works printed but not linked: 1
- St John RK, King A, de Jong D, Bodie-Collins M, Squires SG, Tam TW. Border screening for SARS. Emerg Infect Dis. 2005;11(1):6-10.
Cited by
Items 101–147 of 147
der Heiden, M. A., Buchholz, U., Krause, G., Kirchner, G., Claus, H., & Haas, W. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008356 · Cited by 7
“As has been shown for SARS, entry screening methods are unlikely to detect more than 10% of imported infections and the positive predictive value of temperature screening is low especially at the beginning of a pandemic [4,5].”
MethodInfrared Thermal Imaging Standards for Human Fever Detection
Ring, F. J., & Ng, E. Y. K. (2012) · CRC Press eBooks · doi:10.1201/b12938-23 · Cited by 7
Thermography based diagnosis of ruptured anterior cruciate ligament (ACL) in canines
Lama, N., Umbaugh, S. E., Mishra, D. K., Dahal, R., Marino, D. J., & Sackman, J. J. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2237462 · Cited by 6
Furuichi, M., Makie, T., Honma, Y., Isoda, T., & Miyake, S. (2014) · Japanese Journal of Infectious Diseases · doi:10.7883/yoken.jjid.2014.242 · Cited by 6
“The usefulness of thermography for influenza, which has a similar incubation period, has been reported (6).”
BackgroundBody surface infrared thermometry in patients with central venous cateter-related infections
Silvah, J. H., de Lima, C. M. M., de Unamuno, M. D. R. D. L., Schetino, M. A. A., Schetino, L. P. L., Fassini, P. G., Brandão, C., Basile-Filho, A., da Cunha, S. F. D. C., & Marchini, J. S. (2015) · Einstein (São Paulo) · doi:10.1590/s1679-45082015ao3397 · Cited by 6
“(21-23) Its principle is that heat emitted by the body can be detected in the infrared radiation spectrum through a remote sensor.(24)”
Su, C.-P., Wang, Y.-Y., Ku, K.-C., & Fang, C. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225840 · Cited by 6
“A previous review article concluded that the effectiveness of non-contact infrared thermometers in detecting symptomatic passengers was limited when fever prevalence among passengers was less than 1% [23].”
BackgroundBiomechanical and Thermographic Analysis in the Transtibial Prosthesis Socket - Stump Interface
Živčák, J., Hudák, R., & Rajťúková, V. (2015) · Acta Mechanica Slovaca · doi:10.21496/ams.2015.011 · Cited by 6
Mouchtouri, V. Α., Bartlett, C. L. R., Jaremin, B., Nichols, G. L., Paux, T., Riemer, T., Black, N., Varela-Martínez, C., Swaan, C. M., Schlaich, C. C., et al. (2010) · PubMed · Cited by 6
A Novel Non-contact Infection Screening System Based on Self-Organizing Map with K-means Clustering
Sun, G., Abe, S., Takei, O., Hakozaki, Y., & Matsui, T. (2011) · Communications in computer and information science · doi:10.1007/978-3-642-27157-1_14 · Cited by 5
“A thermography based screening method has been adopted in detecting influenza and other infectious diseases at places of mass gathering, such as, international airports, hospital outpatient units and public health centers [13].”
MethodNajmi, A., Kaore, S. N., Ray, A., & Sadasivam, B. (2020) · Journal of Family Medicine and Primary Care · doi:10.4103/jfmpc.jfmpc_1764_20 · Cited by 5
“9–76%),[6] a high proportion of the individuals, mistakenly classified as febrile and subsequently advised for COVID‐19 testing and medical management, might be aroused, generating hostile reactions.”
BackgroundInfluentialMei, G., Peng, S., Zeng, Z., Liao, T., & Huang, Y. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2112/1/012024 · Cited by 5
Gorczewska, I., Szurko, A., Kiełboń, A., Stanek, A., & Cholewka, A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192416511 · Cited by 5
Xia, C., Wang, J., Wang, Z., & Shen, J. (2024) · BMC Public Health · doi:10.1186/s12889-024-20479-9 · Cited by 4
“For patients or asymptomatic carriers of infectious diseases, it is imperative that care-taking staff supervise them to ensure they wear masks, wash their hands frequently, improve indoor ventilation, and arrange for them to sit at the window to minimize close contact with other passengers [20–22].”
BackgroundScreening of Asymptomatic Passengers’ Departure from Qatar: A Retrospective Observational Study
Dergaa, I. (2021) · Open Access Journal of Biomedical Science · doi:10.38125/oajbs.000341 · Cited by 4
“It has thus become pertinent to acknowledge that basic screening method is not very systemised and effective in order to curb the transmission of COVID-19 [10,11].”
BackgroundEffect of vocal loading on throat temperature in young phono-normal adults
Lokheshwar, S., & Rajasudhakar, R. (2018) · Journal of Laryngology and Voice · doi:10.4103/jlv.jlv_6_18 · Cited by 6
Automatic Door Lock with Hand Cleaning and Infra-Red Temperature Detection System
Galina, M., Prasetyo, G. E., Sitompul, E., & Suhartomo, A. (2022) · ELKOMIKA Jurnal Teknik Energi Elektrik Teknik Telekomunikasi & Teknik Elektronika · doi:10.26760/elkomika.v10i2.364 · Cited by 4
Automatic Intelligent Asymmetry Detection Using Digital Infrared Imaging with K-Means Clustering
Kim, K.-B., & Song, D. H. (2015) · International Journal of Fuzzy Logic and Intelligent Systems · doi:10.5391/ijfis.2015.15.3.180 · Cited by 4
“Over several decades, with rapidly developing computer technology and artificial intelligence, DITI has been extensively studied in many fields of medical science, such as diabetic neuropathy [6], vascular disorders [7], fever screening [8], dry eye syndrome diagnosis [9], and breast cancer detection [10-13], and even…”
BackgroundPossibilities and limits of human temperature measurement by thermographic methods
Švantner, M., Lang, V., Skála, J., Kohlschütter, T., Honner, M., Muzika, L., & Kosová, E. (2022) · IEEE International Workshop on Metrology for Living Environment (MetroLivEnv) · doi:10.1109/metrolivenv54405.2022.9826942 · Cited by 4
Suzuki, T. (2025) · Sensors · doi:10.3390/s26010098 · Cited by 3
“Moreover, facial temperature can be affected by various factors, such as antipyretic consumption, alcohol consumption, cosmetics, pregnancy, and physical activity [4,5], leading to false-negative results and compromising the accuracy of temperature measurements when relying solely on thermography.”
T-FAKE: Synthesizing Thermal Images for Facial Landmarking
Flotho, P., Piening, M., Kukleva, A., & Steidl, G. (2025) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52734.2025.02454 · Cited by 10
“Due to the close relation of body temperature with physiological states, thermal imaging of faces emerged as an important tool for screening infectious diseases [4, 40, 47] and for the analysis of neurocognitive and affective states [21].”
Lefèvre, B., Blanchon, T., Saint-Martin, P., Tattevin, P., Che, D., Caumes, É., Pitel, T., Rossignol, L., Dournon, N., Duval, X., et al. (2020) · Infectious Diseases Now · doi:10.1016/j.medmal.2020.06.002 · Cited by 3
Mahabala, C., Dakappa, P. H., & Gupta, A. R. (2022) · F1000Research · doi:10.12688/f1000research.74876.1 · Cited by 3
Mahabala, C., Dakappa, P. H., & Gupta, A. R. (2022) · F1000Research · doi:10.12688/f1000research.74876.3 · Cited by 3
“5°C to 38°C in various studies.(14,15) The Brighton Collaboration Fever Working Group has defined fever as temperature >38°C.”
BackgroundNon-fever COVID-19 Detection by Infrared Imaging
Brioschi, M. L., Neto, C. D., de Toledo, M., Moreira, M. A., Civiero, N., Neves, E. B., VARGAS, J. V. C., & Teixeira, M. J. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-19660-7_6 · Cited by 3
Maintaining Human Health at the Border of Taiwan
Chiu, H.-H., Hsieh, J.-W., Wu, Y.-C., Chou, J.-H., & Chang, F. (2014) · Biosecurity and Bioterrorism Biodefense Strategy Practice and Science · doi:10.1089/bsp.2014.0016 · Cited by 3
“9,22,23 From the point of view of policy planning, it is expected that government resources can be used in a more efficient and effective way.”
Monitoring of Thermal Processes for Medical Applications Using Infrared Thermography
Lin, S. (2017) · Cited by 3
Švantner, M., Lang, V., Skála, J., Kohlschütter, T., Šroub, J., Muzika, L., Klepáček, J., & Honner, M. (2024) · Infrared Physics & Technology · doi:10.1016/j.infrared.2024.105176 · Cited by 2
Integrating emergency preparedness competency frameworks in workforce development training
Tabche, C., Atwan, Z., & Rawaf, S. (2024) · Mass gathering medicine. · doi:10.1016/j.mgmed.2024.100008 · Cited by 2
Bitar, D., Tarantola, A., Capek, I., Barboza, P., & Che, D. (2009) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/s0001-4079(19)32418-5 · Cited by 2
“L’expertise intègre de plus en plus souvent les modèles mathématiques qui permettent par exemple d’estimer le risque d’importation du Sras ou de la dengue en Europe [12, 13] ou d’évaluer l’impact des mesures de contrôle aux frontières pour la réduction de la diffusion d’une pandémie grippale [14-16].”
BackgroundSelf-citationDuan, A., Li, J., Yang, Z., & He, Y. (2023) · Infection Genetics and Evolution · doi:10.1016/j.meegid.2023.105479 · Cited by 2
Sujatha, C., Krishnankutty, S. L., Khader, K., Kanmani, A. K., Rahul, A., Suresh, M. M., Sudha, R., & Indu, P. S. (2021) · International Journal of Travel Medicine and Global Health · doi:10.34172/ijtmgh.2021.13 · Cited by 2
Shah, S. M. A., Aw, T. C., Blair, I., Hashmey, R., & Sheek-Hussein, M. (2011) · Safety and Health at Work · doi:10.5491/shaw.2011.2.1.83 · Cited by 2
“The thermal scanners will detect individuals with fever from whatever cause, but will not necessarily detect those with early H1N1 infection, especially if they are afebrile [3].”
BackgroundAutomated segmentation of regions of interest from thermal images of hands
Gauci, J., Falzon, O., Camilleri, K. P., Formosa, C., Gatt, A., Ellul, C., Mizzi, S., Mizzi, A., Cassar, K., Delia, C. S., et al. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037690 · Cited by 2
“other health issues and have been investigated in various studies [3], [4].”
BackgroundEfficacy of Fixed Infrared Thermography for Identification of Subjects with Influenza-Like Illness
Hinnerichs, C. M. (2012) · ScholarWorks (Walden University) · Cited by 3
Gadgets and armamentarium of maxillofacial surgeons during coronavirus pandemic
Tayal, S., Datarkar, A. N., & Anukula, H. S. (2020) · Annals of Maxillofacial Surgery · doi:10.4103/ams.ams_164_20 · Cited by 1
Cosmetic Practices in the COVID-19 Era
Narla, S., Watchmaker, J. D., Ozog, D., & Rohrer, T. E. (2021) · Advances in Cosmetic Surgery · doi:10.1016/j.yacs.2021.01.004 · Cited by 1
Influenza epidémica A (H1N1). Algunas respuestas para los no expertos
González, H. B. (2009) · Médica Sur
Fernández, I. R. (2015) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.39072
LA THERMOGRAPHIE CHEZ LE CHIEN SAIN : ÉTUDE ÉXPERIMENTALE
Thierry, F. (2013) · HAL
Hsieh, S., & Zhou, X. (2018) · Thermosense: Thermal Infrared Applications · doi:10.1117/12.2305570
Gómez, F. B., Hecht-Chau, G., Martín, E. B.-S., Toro-Salinas, A., Henríquez, M., García-Pelayo, S., Cuevas, M. J., & Alvear-Órdenes, I. (2023) · International Journal of Morphology · doi:10.4067/s0717-95022023000601824 · Cited by 1
Kumar, D. S., Ratheesh, R., Poojadharshini, M., Kalyani, P. S. M., & Pooja, S. (2023) · medRxiv · doi:10.1101/2023.12.21.23300100
“[7 ][8][9] Despite the increasing adoption of NCITs, limited comprehensive data exists, especially from developing nations, regarding their effectiveness for fever detection, particularly among HCWs in varying environmental conditions.”
BackgroundAATI, M. H. A., WARQASH, A. M. A. A., ZELAEI, N. A., JAHSHAR, A. Y. A., ALGHAMDI, E. I. S., MUSHAHHIM, M. A. A., ALGHAMDI, A. F. M., Althobaiti, A., ALWADIE, A. H. H., & ALSAGOOR, A. S. (2024) · Journal of Ecohumanism · doi:10.62754/joe.v3i8.5337
Evaluation for interrater and intrarater reliability of intraoral infrared camera: a pilot study
Lee, H.-S., Lee, S.-J., Cho, I., Shin, H., & Kang, D. (2025) · Journal of Dental Rehabilitation and Applied Science · doi:10.14368/jdras.2025.41.2.110
Facente, S. N., Hunter, L. A., Packel, L. J., Li, Y., Harte, A., Nicolette, G. W., McDevitt, S. L., Petersen, M., & Reingold, A. L. (2021) · Figshare · doi:10.6084/m9.figshare.16633164
Metadata
- Authors
- Bitar, D., Goubar, A., & Desenclos, J. C.
- Affiliations
- Institut de Veille Sanitaire (FR)
- ORCID
- Goubar, A
- Venue
- Eurosurveillance
- Published
- 2009-02-12
- Volume
- 14
- Issue
- 6
- ISSN
- 1025-496X (ISSN-L)
- 1560-7917
- OpenAlex
- W330907127
- Cited by
- 150
- References
- 25
- Citations by year
- 2025: 3 · 2024: 5 · 2023: 6 · 2022: 14 · 2021: 24 · 2020: 19 · 2019: 4 · 2018: 5 · 2017: 7 · 2016: 5 · 2015: 10 · 2014: 13 · 2013: 9 · 2012: 4
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Eurosurveillance (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- European Commission
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Travel-related health issues
- Health Sciences › Medicine › Epidemiology › Influenza Virus Research Studies
- Keywords
- non-contact infrared thermometer, fever screening, pandemic influenza, international airports, border control, screening sensitivity and specificity, positive predictive value, negative predictive value
- MeSH terms
- Disease Outbreaks, Humans, Influenza, Human, Mass Screening, Population Surveillance, Risk Factors, Sensitivity and Specificity, Thermography, Global Health, Reproducibility of Results, Incidence, Risk Assessment, Internationality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.