International travels and fever screening during epidemics: a literature review on the effectiveness and potential use of non-contact infrared thermometers
Open accessThe DOI matches its Crossref record; 24 of the 25 references it cites were found in a registry or an index.
Abstract
Several countries plan to introduce non-contact infrared thermometers (NCIT) at international airports in order to detect febrile passengers, thus to delay the introduction of a novel influenza strain. We reviewed the existing studies on fever screening by NCIT to estimate their efficacy under the hypothesis of pandemic influenza. Three Severe Acute Respiratory Syndrome (SARS) or dengue fever interventions in airports were excluded because of insufficient information. Six fever screening studies in other gathering areas, mainly hospitals, were included (N= 176 to 72,327 persons; fever prevalence= 1.2% to 16.9%). Sensitivity varied from 4.0% to 89.6%, specificity from 75.4% to 99.6%, positive predictive value (PPV) from 0.9% to 76.0% and negative predictive value (NPV) from 86.1% to 99.7%. When we fixed fever prevalence at 1% in all studies to allow comparisons, the derived PPV varied from 3.5% to 65.4% and NPV was >=99%. The low PPV suggests limited efficacy of NCIT to detect symptomatic passengers at the early stages of a pandemic influenza, when fever prevalence among passengers would be =<1%. External factors can also impair the screening strategy: passengers can hide their symptoms or cross borders before symptoms occur. These limits should be considered when setting up border control measures to delay the pandemic progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Overall, previous studies using clinical data from hospitals and transit centers have been inconclusive regarding the use and effectiveness of NCITs as a screening method during SARS and influenza outbreaks.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [11]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Bitar et al.11 in a similar clinical study reported the sensitivity of NCITs to vary widely from approximately 4–90%.”
From Clinical evaluation of non-contact infrared thermometers (2021) · cites this paper as [11]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modelling strategies for controlling SARS outbreaks
Gumel, A. B., Ruan, S., Day, T., Watmough, J., Brauer, F., van den Driessche, P., Gabrielson, D., Bowman, C., Alexander, M. E., Ardal, S., et al. (2004) · Proceedings of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rspb.2004.2800 · Cited by 397
Nonpharmaceutical Interventions for Pandemic Influenza, International Measures
World Health Organization Writing Group (2006) · Emerging Infectious Diseases · doi:10.3201/eid1201.051370 · Cited by 326
Delaying the International Spread of Pandemic Influenza
Cooper, B. S., Pitman, R. J., Edmunds, W. J., & Gay, N. J. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030212 · Cited by 305
A perspective on medical infrared imaging
Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y. (2005) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331333158 · Cited by 283 · cited 9×
“While ribavirin has been shown to be effective in early-stage arenavirus infections, particularly Lassa virus [ 2 ], in the absence of proven effectiveness for prophylaxis [3], oral ribavirin was not recommended for persons who might have been exposed to the case described here.”
BackgroundMethodInfluentialPublic health interventions and SARS spread, 2003
Bell, D. M., & World Health Organization Working Group on Prevention of International and Community Transmission of SARS (2004) · Emerging Infectious Diseases · doi:10.3201/eid1011.040729 · Cited by 272
Will travel restrictions control the international spread of pandemic influenza?
Hollingsworth, T. D., Ferguson, N. M., & Anderson, R. M. (2006) · Nature Medicine · doi:10.1038/nm0506-497 · Cited by 218 · cited 1×
“Modelling works show that border control strategies aimed at reducing the risk of introduction of SARS or influenza in a country have poor sensitivity [17] and limited impact [ 18-21 ].”
BackgroundAnalysis of IR thermal imager for mass blind fever screening
Ng, E. Y. K., Kawb, G. J. L., & Chang, W. M. (2004) · Microvascular Research · doi:10.1016/j.mvr.2004.05.003 · Cited by 182 · cited 6×
“Finally, environmental factors can also affect the measurements [2, 10 ], such as the subjectsensor distance, the ambient temperature or humidity and the surrounding ventilation systems, as well as the fact that the person tested should remain immobile for a few seconds in front of the”
BackgroundMethodInfluentialInfrared Thermography to Mass-Screen Suspected Sars Patients with Fever
Chiu, W., Lin, P., Chiou, H. Y., Lee, W. S., Lee, C. N., Yang, Y. Y., Lee, H. M., Hsieh, M. S., Hu, C., Ho, Y. S., et al. (2005) · Asia Pacific Journal of Public Health · doi:10.1177/101053950501700107 · Cited by 111 · cited 3×
“These selected studies summarised in Table 1, included: one in Singapore [10], two in Hong Kong [11,12], two in Taiwan [ 13 ,14] and finally one in France [15].”
BackgroundMethodInfluentialScreening for Fever by Remote-sensing Infrared Thermographic Camera
Chan, L., Cheung, G. T. Y., Lauder, I. J., & Kumana, C. R. (2006) · Journal of Travel Medicine · doi:10.2310/7060.2004.19102 · Cited by 109
SARS in Singapore – Key Lessons from an Epidemic
Tan, C.-C. (2006) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v35n5p345 · Cited by 102
Research works printed but not linked: 1
- St John RK, King A, de Jong D, Bodie-Collins M, Squires SG, Tam TW. Border screening for SARS. Emerg Infect Dis. 2005;11(1):6-10.
Cited by
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Infrared thermography (IRT) applications for building diagnostics: A review
Kylili, A., Fokaides, P. A., Christou, P., & Kalogirou, S. A. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.08.005 · Cited by 526
Estimated effectiveness of symptom and risk screening to prevent the spread of COVID-19
Gostic, K., Gomez, A. C., Mummah, R. O., Kucharski, A. J., & Lloyd-Smith, J. O. (2020) · eLife · doi:10.7554/elife.55570 · Cited by 417
Travel implications of emerging coronaviruses: SARS and MERS-CoV
Al-Tawfiq, J. A., Zumla, A., & Memish, Z. A. (2014) · Travel Medicine and Infectious Disease · doi:10.1016/j.tmaid.2014.06.007 · Cited by 176
“In an analysis of the effectiveness of non-contact infrared thermometers (NCIT), the calculated positive predictive value (PPV) was 0.9e76.0% and negative predictive value (NPV) was 86.1e99.7% based on fever prevalence of 1.2e16.9% [87] .”
BackgroundFever screening during the influenza (H1N1-2009) pandemic at Narita International Airport, Japan
Nishiura, H., & Kamiya, K. (2011) · BMC Infectious Diseases · doi:10.1186/1471-2334-11-111 · Cited by 140
“In addition to the limited diagnostic performance of fever screening in identifying febrile influenza cases, it should be remembered that the readings of infrared thermoscanners are known to be influenced by other confounding factors, most notably by age and outdoor temperature [15,20-22].”
BackgroundInfluentialComparison of 3 Infrared Thermal Detection Systems and Self-Report for Mass Fever Screening
Nguyen, A. V., Cohen, N. J., Lipman, H., Brown, C. M., Molinari, N.-A., Jackson, W. L., Kirking, H., Szymanowski, P., Wilson, T. W., Salhi, B. A., et al. (2010) · Emerging Infectious Diseases · doi:10.3201/eid1611.100703 · Cited by 138
“Many types of ITDS are available, ranging from inexpensive hand-held point-and-shoot devices with laser sighting to hand-held cameras with light-emitting diode displays, wall-mounted cameras, and portable cameras on tripods such as the ones used in this study (19,23,29).”
BackgroundMethodApplication of infrared thermography in computer aided diagnosis
Faust, O., Acharya, U. R., Ng, E. Y. K., Hong, T. J., & Yu, W. (2014) · Infrared Physics & Technology · doi:10.1016/j.infrared.2014.06.001 · Cited by 128
“On the positive side, this imaging modality saves time (temperature is displayed within a few seconds) and it reduces close contacts with infected individuals [249].”
Skip the Trip: Air Travelers' Behavioral Responses to Pandemic Influenza
Fenichel, E. P., Kuminoff, N. V., & Chowell, G. (2013) · PLoS ONE · doi:10.1371/journal.pone.0058249 · Cited by 116
“Air travel may increase private infection risk beyond an acceptable level, and public health interventions related to travel and airport surveillance programs may benefit travelers [17,18].”
BackgroundNon-invasive continuous core temperature measurement by zero heat flux
Teunissen, L. P. J., Klewer, J., de Haan, A., de Koning, J. J., & Daanen, H. A. M. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/5/005 · Cited by 107
Global expansion of COVID-19 pandemic is driven by population size and airport connections
Coelho, M. T. P., Rodrigues, J. F. M., Medina, A. M., Scalco, P. R., Terribile, L. C., Vilela, B., Diniz‐Filho, J. A. F., & Dobrovolski, R. (2020) · PeerJ · doi:10.7717/peerj.9708 · Cited by 106
Negishi, T., Abe, S., Matsui, T., Liu, H., Kurosawa, M., Kirimoto, T., & Sun, G. (2020) · Sensors · doi:10.3390/s20082171 · Cited by 114
“4%, indicating the limited efficacy for detecting symptomatic passengers [7].”
BackgroundBody temperature and clinical thermometry
Childs, C. (2018) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64074-1.00029-x · Cited by 100
“…in global outbreaks such as the severe acute respiratory disease pandemic in 2003, swine flu pandemic (H1N1) in 2009, and Ebola epidemic (2014), border entry and exit screening measures (Bitar et al., 2009) were imposed at international airports, seaports, and country borders (Chiu et al., 2005).”
BackgroundThe Revised International Health Regulations: A Framework For Global Pandemic Response
Katz, R., & Fischer, J. E. (2010) · Cited by 83
Thermal Image Scanning for Influenza Border Screening: Results of an Airport Screening Study
Priest, P. C., Duncan, A. R., Jennings, L. C., & Baker, M. G. (2011) · PLoS ONE · doi:10.1371/journal.pone.0014490 · Cited by 79
“However to date no studies have been reported that tested ITIS negative travellers for either fever or influenza infection [12,13].”
BackgroundChiappini, E., Sollai, S., Longhi, R., Morandini, L., Laghi, A., Osio, C. E., Persiani, M., Lonati, S., Picchi, R., Bonsignori, F., et al. (2011) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2010.03565.x · Cited by 77
Epidermal RFID passive sensor for body temperature measurements
Milici, S., Amendola, S., Bianco, A. G., & Marrocco, G. (2014) · IEEE International Conference on RFID Technology and Applications (RFID-TA) · doi:10.1109/rfid-ta.2014.6934216 · Cited by 78
“Current technologies to quickly and non-invasively collect the body temperature are mostly based on non-contacting infrared thermometers (NCIT) [2], [3] that however require to place the instrument’s probe very close to the body district.”
BackgroundZhou, Y., Ghassemi, P., Chen, M., McBride, D. R., Casamento, J. P., Pfefer, T. J., & Wang, Q. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.9.097002 · Cited by 91
Khan, K., Memish, Z. A., Chabbra, A., Liauw, J., Hu, W., Janes, D. A., Sears, J., Arino, J., Macdonald, M., Calderon, F., et al. (2010) · Journal of Travel Medicine · doi:10.1111/j.1708-8305.2010.00397.x · Cited by 76
Khan, K., Sears, J., Hu, V. W., Brownstein, J. S., Hay, S. I., Kossowsky, D., Eckhardt, R., Chim, T., Berry, I., Bogoch, I. I., et al. (2013) · PLoS Currents · doi:10.1371/currents.outbreaks.a7b70897ac2fa4f79b59f90d24c860b8 · Cited by 83
A novel screening method for influenza patients using a newly developed non-contact screening system
Matsui, T., Hakozaki, Y., Suzuki, S. V., Usui, T., Kato, T., Hasegawa, K., Sugiyama, Y., Sugamata, M., & Abe, S. (2010) · Journal of Infection · doi:10.1016/j.jinf.2010.01.005 · Cited by 70
“4%.(4) This low PPV indicates the limited effectiveness of thermography in detecting early-stage influenza symptoms.”
BackgroundEvaluation of Border Entry Screening for Infectious Diseases in Humans
Selvey, L. A., Antão, C., & Hall, R. (2014) · Emerging infectious diseases · doi:10.3201/eid2102.131610 · Cited by 83
“A review of hospital-based studies examining the efficacy of ITISs in detecting fever found that the sensitivity of fever detection ranged from 4% to 89.6%, and the positive predictive value with a 1% prevalence of fever ranged from 3.5% to 65.4% (22) .”
BackgroundInfluentialSun, G., Matsui, T., Hakozaki, Y., & Abe, S. (2014) · Journal of Infection · doi:10.1016/j.jinf.2014.12.007 · Cited by 64
“In the present study, although the 35 influenza patients were treated with anti-viral medication and more than half of the patients had normal body temperature, our system attained higher detection sensitivity than that reported in some recent studies using only thermography.(9,25) This higher sensitivity can be attri…”
ResultEffectiveness of interventions targeting air travellers for delaying local outbreaks of SARS-CoV-2
Clifford, S., Pearson, C. A. B., Klepac, P., van Zandvoort, K., Quilty, B. J., CMMID COVID-19 working group, Eggo, R. M., & Flasche, S. (2020) · Journal of Travel Medicine · doi:10.1093/jtm/taaa068 · Cited by 59
Aggarwal, N., Garg, M., Dwarakanathan, V., Gautam, N., Kumar, S. S., Jadon, R. S., Gupta, M., & Ray, A. (2020) · Journal of Travel Medicine · doi:10.1093/jtm/taaa193 · Cited by 69
“At these initial stages, we found thermal screening to have a poor PPV, meaning that most of the subjects deemed to be febrile on screening would turn out to be afebrile (false positives), which may also evoke undue anxiety and anguish amongst these individuals.(43) In addition to the concerns about the diagnostic acc…”
BackgroundInfluentialInfrared thermal imaging of the inner canthus of the eye as an estimator of body core temperature
Teunissen, L. P. J., & Daanen, H. A. M. (2011) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.554595 · Cited by 59
“A recent review observed a wide range in fever detection sensitivity from 4 to 90%, while specificity ranged from 75 to almost 100% [4].”
BackgroundRubia-Rubia, J., Arias, Á., Sierra, A., & Aguirre‐Jaime, A. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2010.11.003 · Cited by 61
Khaksari, K., Nguyen, T., Hill, B. Y., Perrault, J., Gorti, V., Blick, E., Gonzalez Cano, T., Shadgan, B., Quang, T., Malpani, R., et al. (2021) · Journal of medical imaging · doi:10.1117/1.jmi.8.s1.010901 · Cited by 55
Gostic, K. M., Kucharski, A. J., & Lloyd‐Smith, J. O. (2015) · eLife · doi:10.7554/elife.05564 · Cited by 61
“Fever screening at point of arrival has been criticized, however, because long incubation periods and imperfect efficacy of fever screening devices reduce the probability of detecting symptoms in infected arriving passengers (Pitman et al., 2005; Bitar et al., 2009; Mabey et al., 2014).”
InfluentialInfrared thermography detects febrile and behavioural responses to vaccination of weaned piglets
Cook, N. J., Chabot, B., Lui, T., Bench, C. J., & Schaefer, A. L. (2014) · animal · doi:10.1017/s1751731114002481 · Cited by 61
“The technology has mostly been used to screen people at airports for the purposes of disease surveillance (Bitar, 2009), but also has a role in veterinary medical diagnostics (McCafferty, 2007).”
MethodKhan, K., Freifeld, C. C., Wang, J., Mekaru, S. R., Kossowsky, D., Sonricker, A. L., Hu, W., Sears, J., Chan, A. T., & Brownstein, J. S. (2010) · Canadian Medical Association Journal · doi:10.1503/cmaj.100093 · Cited by 49
Wang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J. P., & Pfefer, T. J. (2021) · Sensors · doi:10.3390/s22010215 · Cited by 48
“Although NCITs are highly portable, inexpensive, and have been widely used for fever screening during epidemics [20], their accuracy has been called into question, particularly relative to IRTs [21,22].”
BackgroundKhan, K., Eckhardt, R., Brownstein, J. S., Naqvi, R. M., Hu, W., Kossowsky, D., Scales, D. A., Arino, J., MacDonald, M., Wang, J., et al. (2013) · Bulletin of the World Health Organization · doi:10.2471/blt.12.114777 · Cited by 48
de Diego, A. C. P., Sánchez-Cordón, P. J., Pedrera, M., Martínez‐López, B., Gomez-Villamandos, J. C., & Sánchez‐Vizcaíno, J. M. (2013) · The Veterinary Journal · doi:10.1016/j.tvjl.2013.07.013 · Cited by 58
“This radiation is proportional to the surface temperature of the body (Bitar et al., 2009) , and is evaluated using a thermographic camera, which produces images with different colour patterns depending on the temperature of the imaged objects.”
BackgroundDoes the technique employed for skin temperature assessment alter outcomes? A systematic review
Bach, A. J. E., Stewart, I. B., Minett, G. M., & Costello, J. T. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/r27 · Cited by 67
The use of infrared thermal imaging in the diagnosis of deep vein thrombosis
Kaçmaz, S., Erçelebi, E., Zengin, S., & Cindoruk, Ş. (2017) · Infrared Physics & Technology · doi:10.1016/j.infrared.2017.09.005 · Cited by 47
Non-contact infrared assessment of human body temperature: The journal Temperature toolbox
Foster, J., Lloyd, A. B., & Havenith, G. (2021) · Temperature · doi:10.1080/23328940.2021.1899546 · Cited by 46
“Although T skin (measured over 10-sites) during severe fever did not reach the typical 37.5°C threshold as advised in mass screening studies [33], a single site that better reflects T core (i.e. inner eye-canthus) would likely, albeit speculatively, have surpassed such a threshold in this case.”
InfluentialTay, M. R., Low, Y. L., Zhao, X., Cook, A. R., & Lee, V. J. (2015) · Public Health · doi:10.1016/j.puhe.2015.07.023 · Cited by 46
“Various studies have examined the role of ITDS for fever screening at airports,(8,23) emergency departments(12,14) and outpatient consultations(15) over a range of age groups.(13,24) Caution has been expressed in the use of ITDS, due to several confounders, including individual factors, the targeted body area and envi…”
BackgroundResultInfluentialClinical evaluation of non-contact infrared thermometers
Sullivan, S. J. L., Rinaldi, J. E., Hariharan, P., Casamento, J. P., Baek, S., Seay, N., Vesnovsky, O., & Topoleski, L. D. T. (2021) · Scientific Reports · doi:10.1038/s41598-021-99300-1 · Cited by 44
What Ebola tells us about outbreak diagnostic readiness
Perkins, M. D., & Kessel, M. (2015) · Nature Biotechnology · doi:10.1038/nbt.3215 · Cited by 44
Millikelvin-resolved ambient thermography
Tang, K., Dong, K., Nicolai, C. J., Li, Y., Li, J., Lou, S., Qiu, C., Raulet, D. H., Yao, J., & Wu, J. (2020) · Science Advances · doi:10.1126/sciadv.abd8688 · Cited by 49
“Thermography is broadly applied in areas such as cancer detection (22), diagnosis of diabetic neuropathy and vascular disorder (23), fever screening (24), dental care (25), and surgery (26).”
BackgroundEthics for integrating emerging technologies to contain COVID ‐19 in Zimbabwe
Mbunge, E., Fashoto, S. G., Akinnuwesi, B. A., Metfula, A. S., Simelane, S., & Ndumiso, N. (2021) · Human Behavior and Emerging Technologies · doi:10.1002/hbe2.277 · Cited by 51
Ammer, K., & Ring, F. J. (2019) · doi:10.1201/9780429019982 · Cited by 55
Apa, H., Gözmen, S., Bayram, N., Çatkoğlu, A., Devrim, F., Karaarslan, U., Günay, İ., Ünal, N., & Devrim, İ. (2013) · Pediatric Emergency Care · doi:10.1097/pec.0b013e3182a2d419 · Cited by 43
“In a recent review on the use of these thermometers for screening of international travelers, the positive predictive value of these devices was found to be poor.(36) For example, most devices tested in previous studies were not currently manufactured for a fever screening purpose(38); thus, findings should be interpr…”
BackgroundKuan, M.-M., & Chang, F. (2012) · BMC Infectious Diseases · doi:10.1186/1471-2334-12-182 · Cited by 47
“Despite the presence of devices with improved performance and affordable implementation costs, there is still a possibility for infected travelers to not be detected by screening and subsequently trigger an outbreak, which would cause a loss of public confidence in the pandemic response [12-15].”
BackgroundInfluentialA crucial time for public health preparedness: Zika virus and the 2016 Olympics, Umrah, and Hajj
Elachola, H., Gozzer, E., Zhuo, J., & Memish, Z. A. (2016) · The Lancet · doi:10.1016/s0140-6736(16)00274-9 · Cited by 47
Ramey, D. W., Bachmann, K., & Lee, M. L. (2011) · Journal of Equine Veterinary Science · doi:10.1016/j.jevs.2011.02.009 · Cited by 40
“7% [4].”
Design and Development of a Low Cost, Non-Contact Infrared Thermometer with Range Compensation
Goh, N. W.-J., Poh, J.-J., Yeo, J. Y., Aw, B. J.-J., Lai, S. C., Cheng, J. J. W., Tan, C. Y. L., & Gan, S. K. (2021) · Sensors · doi:10.3390/s21113817 · Cited by 37
Usefulness and applicability of infectious disease control measures in air travel: A review
Luigjes-Huizer, Y. L., Swaan, C. M., Leitmeyer, K. C., & Timen, A. (2014) · Travel Medicine and Infectious Disease · doi:10.1016/j.tmaid.2014.11.008 · Cited by 41
Kuan, M.-M., Lin, T., Chuang, J.-H., & Wu, H.-S. (2010) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2009.12.010 · Cited by 34
“All of the dengue cases were confirmed by a reference laboratory at the Research and Diagnostic Center of the Taiwan CDC and tested positive for DENV isolation, DENV RNA detection using real-time reverse transcriptase polymerase chain reaction (real-time RT-PCR), and/or serological diagnosis by capture IgM/IgG ELISA.(…”
BackgroundMethodResultInfluentialStatistical Study on Human Temperature Measurement by Infrared Thermography
Švantner, M., Lang, V., Skála, J., Kohlschütter, T., Honner, M., Muzika, L., & Kosová, E. (2022) · Sensors · doi:10.3390/s22218395 · Cited by 34
“[18] in 2009, research confirming that thermography can be usable for the mass screening of fever was published by Nguyen et al.”
BackgroundMethodDzien, C., Halder, W., Winner, H., & Lechleitner, M. (2020) · Wiener klinische Wochenschrift · doi:10.1007/s00508-020-01754-2 · Cited by 39
Mbunge, E., Millham, R. C., Sibiya, M. N., Fashoto, S. G., Akinnuwesi, B. A., Simelane, S., & Ndumiso, N. (2021) · Sustainable Operations and Computers · doi:10.1016/j.susoc.2021.07.003 · Cited by 37
Hewlett, A. L., Kalil, A. C., Strum, R. A., Zeger, W. G., & Smith, P. W. (2011) · Infection Control and Hospital Epidemiology · doi:10.1086/659404 · Cited by 32
“Screening for fever before diagnosis has been considered one method for separating potentially infectious people.(1) Because manual temperature assessments and subjective questionnaires are time-consuming, the utility of infrared thermography as a fever screening tool was studied in airports and in healthcare settings…”
MethodYao, Y., Sun, G., Matsui, T., Hakozaki, Y., van Waasen, S., & Schiek, M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2479716 · Cited by 31
“However, studies have shown that this approach suffers from low sensitivity and specificity [1].”
BackgroundChen, X., Liu, J., Xiao, F., Chen, S., & Chen, L. (2021) · International Conference on Mobile Systems, Applications, and Services · doi:10.1145/3458864.3467879 · Cited by 28
“An infrared thermometer estimates temperature from a portion of the thermal radiation emitted by the object being measured [2, 17, 28].”
BackgroundAirport arrivals screening during pandemic (H1N1) 2009 influenza in New South Wales, Australia
Gunaratnam, P. J., Tobin, S., Seale, H., Marich, A. J. N., & McAnulty, J. (2014) · The Medical Journal of Australia · doi:10.5694/mja13.10832 · Cited by 28
Liu, L., Wu, W., & McEntire, D. A. (2021) · International Journal of Disaster Risk Reduction · doi:10.1016/j.ijdrr.2021.102516 · Cited by 34
“From a public health emergency perspective, control includes the initiation and implementation of institutional regulatory policies—social distancing policies, case identifications [52], mass screenings, foreign entry suspension [53], and sanitation product distribution mechanisms—as well as surveillance between commu…”
Liang, H., Luo, L., Yang, Z., Di, B., Bai, Z., He, P., Jing, Q., & Zheng, X. (2013) · PLoS ONE · doi:10.1371/journal.pone.0055353 · Cited by 23
“As part of the integrated dengue control program, fever screening at international airports (identifying fever cases by infrared thermal scanner) has been reported to be an effective means of identifying imported dengue cases [38,39].”
Reliability of Non-Contact Infrared Thermometers for Fever Screening Under COVID-19
Lai, F., Li, X., Wang, Q., Luo, Y., Wang, X., Huang, X., Zhang, J., Peng, J., Wang, Q., Fan, L., et al. (2022) · Risk Management and Healthcare Policy · doi:10.2147/rmhp.s357567 · Cited by 27
Wan, H., Wang, L., Zhao, T., Sun, K., Shi, S., Dai, H., Chen, G., Liu, H., & Wang, W. (2022) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3550336 · Cited by 22
“Thus, infrared thermometers are widely used in medical and industry applications [54–56].”
Ascertaining the impact of public rapid transit system on spread of dengue in urban settings
Sanna, M., & Hsieh, Y. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.04.050 · Cited by 24
“…several countries such as Singapore and Taiwan introduced noncontact infrared thermometers (NCIT) at border control such as airports in order to detect febrile passengers, in an attempt to detect imported dengue cases or to delay the introduction of a novel influenza strain (Bitar et al., 2009).”
BackgroundSaunders‐Hastings, P., Reisman, J., & Krewski, D. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0168262 · Cited by 22
“These include the use of non-contact infrared thermometers in airports to detect infected passengers, where studies from the 2009 pandemic found that the positive predictive value ranged from 0.9% to 76.0%, and was likely to be too low to effectively detect and contain pandemic infection [72, 73].”
InfluentialDNA Testing for Family Reunification and the Limits of Biological Truth
Lee, C., & Voigt, T. H. (2019) · Science Technology & Human Values · doi:10.1177/0162243919862870 · Cited by 24
Facente, S. N., Hunter, L. A., Packel, L. J., Li, Y., Harte, A., Nicolette, G., McDevitt, S., Petersen, M., & Reingold, A. L. (2021) · BMC Public Health · doi:10.1186/s12889-021-11697-6 · Cited by 19
“However, multiple studies have found low sensitivity or specificity of temperature monitoring during these prior epidemics [8, 9], even in cases where fever was a very common symptom among people with the disease in question [6, 10, 11].”
BackgroundDescribing, Modelling and Forecasting the Spatial and Temporal Spread of COVID-19: A Short Review
Arino, J. (2021) · Fields Institute communications · doi:10.1007/978-3-030-85053-1_2 · Cited by 22
“The sensitivity and specificity of the thermal detection equipment used is questionable [40].”
MethodWickramage, K. P. (2019) · BioMed Research International · doi:10.1155/2019/3832790 · Cited by 19
Inner Eye Canthus Localization for Human Body Temperature Screening
Ferrari, C., Berlincioni, L., Bertini, M., & Bimbo, A. D. (2021) · Proceedings - International Conference on Pattern Recognition/Proceedings/International Conference on Pattern Recognition · doi:10.1109/icpr48806.2021.9412015 · Cited by 19
“In [2] the authors use both a task-constrained deep convolutional network pretrained to detect 5 keypoints and then to detect 68 keypoints, in combination with OpenPose, to recognize face landmarks in thermal images.”
MethodNoncontact Sensing of Contagion
Khanam, F.-T.-Z., Chahl, L. A., Chahl, J. S., Al‐Naji, A., Perera, A. G., Wang, D., Lee, Y. H., Ogunwa, T., Teague, S., Nguyen, T. X. B., et al. (2021) · Journal of Imaging · doi:10.3390/jimaging7020028 · Cited by 21
Sun, G., Abe, N., Sugiyama, Y., Nguyen, Q. V., Nozaki, K., Nakayama, Y., Takei, O., Hakozaki, Y., Abe, S., & Matsui, T. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611097 · Cited by 18
Germs on a Plane: The Transmission and Risks of Airplane-Borne Diseases
Sevilla, N. L. (2018) · Transportation Research Record Journal of the Transportation Research Board · doi:10.1177/0361198118799709 · Cited by 19
SHUYU Robot: An Automatic Rapid Temperature Screening System
Gong, Z., Jiang, S., Meng, Q., Ye, Y., Li, P., Xie, F., Zhao, H., Lv, C., Wang, X., & Liu, X.-J. (2020) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-020-00455-1 · Cited by 17
Infrared Thermography for Detection of Diabetic Neuropathy and Vascular Disorder
Lahiri, B. B., Bagavathiappan, S., Raj, B., & Philip, J. (2017) · Series in bioengineering · doi:10.1007/978-981-10-3147-2_13 · Cited by 17
Proper use of noncontact infrared thermometry for temperature screening during COVID-19
Hussain, A. S., Hussain, H. S., Betcher, N., Behm, R., & Cagir, B. (2021) · Scientific Reports · doi:10.1038/s41598-021-90100-1 · Cited by 16
Challenges to Global Implementation of Infrared Thermography Technology: Current Perspective
Shterenshis, M. V. (2017) · Central Asian Journal of Global Health · doi:10.5195/cajgh.2017.289 · Cited by 21
Cardwell, K., Jordan, K., Byrne, P., Smith, S. M., Harrington, P., Ryan, M., & O’Neill, M. (2020) · Reviews in Medical Virology · doi:10.1002/rmv.2192 · Cited by 18
“may lead to a false sense of security; conversely, infiltration of cases missed by thermal screening may cause secondary cases and result in a loss of confidence by the public.(36) The impact of non‐contact thermal screening on resources is significant.”
BackgroundBrioschi, M. L., Neto, C. D., de Toledo, M., Neves, E. B., VARGAS, J. V. C., & Teixeira, M. J. (2022) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2022.103444 · Cited by 17
Charpignon, M., Carrel, A., Jiang, Y., Kwaga, T., Cantada, B., Hyslop, T., Cox, C. E., Haines, K., Koomson, V., Dumas, G., et al. (2023) · PLOS Digital Health · doi:10.1371/journal.pdig.0000244 · Cited by 21
Technologies for Fever Screening in the Time of COVID-19: A Review
Adams, S. D., Valentine, A., Bucknall, T. K., & Kouzani, A. Z. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3105962 · Cited by 17
“Secondly, this review only included research from 2009 onwards, however, as a previous study had investigated experiments up to 2009, we would recommend readers to read that work for earlier studies [35].”
BackgroundResultInfluentialRiquet, D., Houel, N., & Bodnar, J. L. (2016) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1193239 · Cited by 15
Shimizu, Y., Koshikawa, H., Imbe, M., Yamaki, T., & Amemiya, K. (2020) · Optics Express · doi:10.1364/oe.397136 · Cited by 14
Chetty, T., Daniels, B. B., Ngandu, N. K., & Goga, A. E. (2020) · South African Medical Journal · doi:10.7196/samj.2020.v110i11.14959 · Cited by 20
“[11] However, screening at the point of entry into and exit from countries is labour intensive, and the protective benefits associated with this type of preventive measure are contradictory, with limited public health impact, or evidence of success and benefits, of such measures.[12] In assessing the benefits of a scr…”
BackgroundBays, D., Bennett, E., & Finnie, T. (2021) · Epidemiology and Infection · doi:10.1017/s0950268821002387 · Cited by 14
Bardou, M., Seng, P., Meddeb, L., Gaudart, J., Honnorat, E., & Stein, A. (2016) · Journal of Infection · doi:10.1016/j.jinf.2016.08.017 · Cited by 12
Sun, G., Abe, S., Takei, O., & Matsui, T. (2011) · International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering · doi:10.1109/icici-bme.2011.6108604 · Cited by 12
“By adding two new parameters, the system had a higher screening accuracy than the system using thermography alone [8, 9].”
MethodInfrared assessment of human facial temperature in the presence and absence of common cosmeticsPreprint
Zheng, K., Dong, R., Wang, H., & Granick, S. (2020) · medRxiv · doi:10.1101/2020.03.12.20034793 · Cited by 12
Spatial immunization to abate disease spreading in transportation hubs
Mazzoli, M., Gallotti, R., Privitera, F., Colet, P., & Ramasco, J. J. (2023) · Nature Communications · doi:10.1038/s41467-023-36985-0 · Cited by 14
Sun, G., Miyata, K., Matsuoka, A., Zhao, Z., Iwakami, S., Kim, S., & Matsui, T. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1016191 · Cited by 11
“4% in detecting the fever-based infectious diseases [10].”
BackgroundThe Validity of Mass Body Temperature Screening with Ear Thermometers in a Warm Thermal Environment
Suzuki, T., Wada, K., Wada, Y., Kagitani, H., Arioka, T., Maeda, K., & Kida, K. (2010) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.222.89 · Cited by 11
Silawan, N., Kusukame, K., Kek, K. J., & Kuan, W. S. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512541 · Cited by 15
“6% [3, 4].”
Kakulu, R. K., Kimaro, E. G., & Mpolya, E. A. (2024) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph21040410 · Cited by 16
“Several studies found varying results after evaluating the effectiveness of POE screening measures in the detection and containment of communicable diseases [10,12].”
ResultVavrinský, E., Zavodnik, T., Debnar, T., Cernaj, L., Kozárik, J., Micjan, M., Nevřela, J., Donoval, M., Kopáni, M., & Kosnacova, H. (2022) · Sensors · doi:10.3390/s22020526 · Cited by 10
“Non-contact thermometers are used at the entrances to buildings where larger groups of people concentrate [38,39].”
BackgroundAutomated Detection of Facial Disorders (ADFD): a novel approach based-on digital photographs
Göçeri, E., & Günay, M. (2017) · Computer Methods in Biomechanics and Biomedical Engineering Imaging & Visualization · doi:10.1080/21681163.2017.1317292 · Cited by 10
Piper, J., Gomis, B., & Lee, K. (2022) · Frontiers in Political Science · doi:10.3389/fpos.2022.834223 · Cited by 10
“Qualitative thematic analysis, based on a hermeneutic approach (Boell and Cecez-Kecmanovic, 2014), was applied to all records and documents, with analysis focusing specifically on the federal government’s border management strategy, its decisionmaking process, and the evidence used to support it.”
MethodSun, G., Vinh, N. Q., Matsuoka, A., Miyata, K., Chen, C., Ueda, A., Kim, S., Hakozaki, Y., Abe, S., Takei, O., et al. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944700 · Cited by 10
“Infrared thermography has been applied to fever screening at airport quarantine stations for almost 10 years after the 2003 SARS outbreak [11, 12].”
MethodDetection of carpal tunnel syndrome by infrared thermography
Maxel, X., Bodnar, J. L., & Stubbe, L. (2014) · Mechanics & Industry · doi:10.1051/meca/2014034 · Cited by 9
Infrared thermographical differentiation of estrus and non-estrus stages of dairy animals
Tiwari, S., Singh, Y., Sirohi, R., Yadav, B., Singh, D. N., Gurung, A., & Shakya, P. (2021) · The Pharma Innovation · doi:10.22271/tpi.2021.v10.i4sa.5953 · Cited by 9
“This radiation is proportional to the surface temperature of the body (Bitar et al., 2009) [5], and is evaluated using a thermographic camera, which produces images with different color patterns depending on the temperature of the imaged objects.”
BackgroundSullivan, S. J. L., Seay, N., Zhu, L. K., Rinaldi, J. E., Hariharan, P., Vesnovsky, O., & Topoleski, L. T. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.05.007 · Cited by 9
A Low-Cost In-situ System for Continuous Multi-Person Fever Screening
Hou, K., Liu, Y., Wei, P., Yang, C., Kang, H., Xia, S., Spada, T., Rundle, A., & Jiang, X. (2022) · ACM/IEEE International Conference on Information Processing in Sensor Networks (IPSN) · doi:10.1109/ipsn54338.2022.00009 · Cited by 9
Sun, G., Vinh, N. Q., Abe, S., Takei, O., Sugamata, M., & Matsui, T. (2013) · International Journal of E-Health and Medical Communications · doi:10.4018/jehmc.2013070102 · Cited by 7
Yao, J. P., Hu, Z., Jiang, H.-Y., & Zhao, X. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103143 · Cited by 7
Metadata
- Authors
- Bitar, D., Goubar, A., & Desenclos, J. C.
- Affiliations
- Institut de Veille Sanitaire (FR)
- ORCID
- Goubar, A
- Venue
- Eurosurveillance
- Published
- 2009-02-12
- Volume
- 14
- Issue
- 6
- ISSN
- 1025-496X (ISSN-L)
- 1560-7917
- OpenAlex
- W330907127
- Cited by
- 150
- References
- 25
- Citations by year
- 2025: 3 · 2024: 5 · 2023: 6 · 2022: 14 · 2021: 24 · 2020: 19 · 2019: 4 · 2018: 5 · 2017: 7 · 2016: 5 · 2015: 10 · 2014: 13 · 2013: 9 · 2012: 4
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Locations
- Eurosurveillance (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- European Commission
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Travel-related health issues
- Health Sciences › Medicine › Epidemiology › Influenza Virus Research Studies
- Keywords
- non-contact infrared thermometer, fever screening, pandemic influenza, international airports, border control, screening sensitivity and specificity, positive predictive value, negative predictive value
- MeSH terms
- Disease Outbreaks, Humans, Influenza, Human, Mass Screening, Population Surveillance, Risk Factors, Sensitivity and Specificity, Thermography, Global Health, Reproducibility of Results, Incidence, Risk Assessment, Internationality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.