CoChat
Cited by 200

The DOI matches its Crossref record.

18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense?

Open access
Hellwig, D., Graeter, T. P., Ukena, D., Groeschel, A., Sybrecht, G. W., Schaefers, H.-J., Kirsch, C.-M. · 2007 · Journal of Nuclear Medicine

Abstract

UNLABELLED: (18)F-FDG PET is the most accurate noninvasive modality for staging mediastinal lymph nodes in lung cancer. Besides using visual image interpretation, some institutions use standardized uptake value (SUV) measurements in lymph nodes. Mostly, an SUV of 2.5 is used as the cutoff, but this choice was never deduced from respective studies. Receiver operating characteristic (ROC) analyses demonstrated that SUV thresholds of more than 4 resulted in the highest accuracy. But these high cutoffs imply high false-negative rates (FNRs). The aim of our evaluation was to determine an optimal SUV threshold and to compare its diagnostic performance with the results of visual interpretation. METHODS: This retrospective study included 95 patients with suspected lung cancer who underwent mediastinoscopy/mediastinal lymphadenectomy after (18)F-FDG PET (90-150 min after 250 MBq of (18)F-FDG). Maximum SUV was measured in 371 lymph node regions biopsied afterward and visually interpreted using a 6-level score (- - - through + + +). Diagnostic performance was assessed by ROC analysis. FNR and false-positive rate (FPR), the sum of both error rates (FNR + FPR), and diagnostic accuracy were plotted against a hypothetical SUV threshold to determine the optimum SUV threshold. RESULTS: SUVs in metastatic lymph nodes were higher (mean +/- SD, 7.1 +/- 4.5; range, 1.4-26.9; n = 70) than in tumor-free lymph node stations (2.4 +/- 1.7; range, 0.6-14.9; n = 301; P < 0.01). Inflammatory lymph nodes exhibited slightly increased SUVs (2.7 +/- 2.0; range, 0.8-14.9; n = 146). The plot of error rates featured a minimum of the sum FNR + FPR for an SUV of 2.5. With increasing SUV threshold, the FPR decreased most prominently up to that value whereas a continuous rise of FNR was noticed. Highest diagnostic accuracy was achieved with an SUV of 4.5. The areas under the ROC curves demonstrated that visual interpretation tends to be more accurate than SUV quantification (visual, 0.930 +/- 0.022; SUV, 0.899 +/- 0.025; P = 0.241). Using an SUV of 2.5 as the threshold, the resulting sensitivity, specificity, and negative predictive value were 89%, 84%, and 96%, respectively. CONCLUSION: For mediastinal staging, the choice of an SUV of 2.5 as the threshold is justified because FNR + FPR is minimized. The resulting high negative predictive value of 96% allows the omission of mediastinoscopy in patients with negative mediastinal findings on (18)F-FDG PET images. For the experienced observer, visual analysis should be relied on primarily, with calculation of the SUV used, at most, as a secondary aid. For the less experienced observer, the SUV may be of greater value.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.107.044362

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 200

Metadata

Authors
Hellwig, D., Graeter, T. P., Ukena, D., Groeschel, A., Sybrecht, G. W., Schaefers, H.-J., & Kirsch, C.-M.
Venue
Journal of Nuclear Medicine
Published
2007-11-01
Volume
48
Issue
11
Pages
1761-1766
ISSN
0161-5505 (ISSN-L)
OpenAlex
W2124173105
Cited by
200
References
0
FWCI
8.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense? https://app.cochat.ai/papers/10.2967/jnumed.107.044362
The paper
Hellwig, D., Graeter, T. P., Ukena, D., Groeschel, A., Sybrecht, G. W., Schaefers, H.-J., & Kirsch, C.-M. (2007). 18F-FDG PET for Mediastinal Staging of Lung Cancer: Which SUV Threshold Makes Sense? Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.107.044362

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.