CoChat

Optimized 124I PET Dosimetry Protocol for Radioiodine Therapy of Differentiated Thyroid Cancer

Open access
Jentzen, Walter, Freudenberg, Lutz, Eising, Ernst G., Sonnenschein, Wilfried, Knust, Jochen, Bockisch, Andreas · 2008 · Journal of Nuclear Medicine
Cited by 166

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Iodine kinetics and lesion dose per administered 131I activity (LDpA) of differentiated thyroid cancer metastases were determined using 124I PET. These data were analyzed to derive an optimized dosimetry protocol. METHODS: We evaluated the time-activity-concentration curves of 37 lesions in 17 patients who had undergone thyroidectomies. LDpA determination involved 124I PET images acquired at 4, 24, 48, 72, and 96 h after intake of a capsule containing 20-40 MBq of 124I. A combination of a linear and a monoexponential or a monoexponential function only parameterized the time-activity-concentration curves. The LDpAs, calculated using data from all 5 PET time points, served as reference. The lesions were classified into 3 groups, according to potential for cure with 131I therapy: low (< or =5 Gy GBq(-1); n = 14), medium (between 5 and 10 Gy GBq(-1); n = 9), or high LDpAs (>10 Gy GBq(-1); n = 14). Using the reference approach, the differences in the empiric kinetic parameters within the LDpA groups were evaluated. The reference LDpAs were compared with those derived from only 2, 3, or 4 PET data points and from 1 adapted 2-point approach. Lin's concordance correlation coefficient (rho c) and the mean absolute percentage deviation in LDpAs were used to assess agreement between simplified and reference approaches. RESULTS: The effective 124I half-life, linear activity-concentration rate (alpha), and 24-h activity concentration (CpA) (the latter 2 per administered 124I activity) differed significantly among the LDpA groups (P < 0.05). LDpAs correlated with 24-h CpAs (r = 0.94, P < 0.001). Using the 4-, 24-, and 96-h measurements, a rho c value of greater than or equal to 0.90 was found, and the mean absolute percentage deviation was less than or equal to 16%. Similar statistical values were obtained for the adapted approach, which was based on 24- and 96-h PET data points only. CONCLUSION: Lesion classification into LDpA groups was feasible using a single PET scan at approximately 24 h. Because of the highly variable kinetics, 1 additional measurement at approximately 96 h was needed to obtain a sufficiently reliable LDpA estimate. The adapted 24-96-h approach appears to be the optimal 124I protocol and is a reliable simplification of the 5-point protocol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.107.047159

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 166

Metadata

Authors
Jentzen, W., Freudenberg, L., Eising, E. G., Sonnenschein, W., Knust, J., & Bockisch, A.
Venue
Journal of Nuclear Medicine
Published
2008-05-15
Volume
49
Issue
6
Pages
1017-1023
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2135807249
Cited by
166
References
8
FWCI
5.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimized 124I PET Dosimetry Protocol for Radioiodine Therapy of Differentiated Thyroid Cancer. https://app.cochat.ai/papers/10.2967/jnumed.107.047159
The paper
Jentzen, W., Freudenberg, L., Eising, E. G., Sonnenschein, W., Knust, J., & Bockisch, A. (2008). Optimized 124I PET Dosimetry Protocol for Radioiodine Therapy of Differentiated Thyroid Cancer. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.107.047159

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.