Diagnostic Accuracy of 11C-Methionine PET for Differentiation of Recurrent Brain Tumors from Radiation Necrosis After Radiotherapy
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
UNLABELLED: We evaluated the diagnostic accuracy of PET with l-methyl-(11)C-methionine ((11)C-MET) for the differentiation of recurrent brain tumors from radiation necrosis. METHODS: Seventy-seven patients who had been previously treated with radiotherapy after primary treatment for metastatic brain tumor (n=51) or glioma (n=26) were studied to clarify the diagnostic performance of (11)C-MET PET in differentiating between recurrent brain tumors and radiation necrosis. A total of 88 PET scans with (11)C-MET were obtained; sometimes more than one scan was obtained when there was an indication of recurrent brain tumor or radiation necrosis. A definitive diagnosis was made on the basis of pathologic examination for recurrent brain tumors and on the basis of pathologic examination or clinical course for radiation necrosis. Several indices characterizing the lesions were determined; these included mean and maximum standardized uptake values (SUV(mean) and SUV(max), respectively) and the ratios of lesion uptake to contralateral normal frontal-lobe gray matter uptake corresponding to the SUV(mean) and the SUV(max) (L/N(mean) and L/N(max), respectively). Receiver-operating-characteristic (ROC) curve analysis was used to determine the optimal index of (11)C-MET PET and cutoff values for the differential diagnosis of tumor recurrence and radiation necrosis. RESULTS: The values of each index of (11)C-MET PET tended to be higher for tumor recurrence than for radiation necrosis. There were significant differences between tumor recurrence and radiation necrosis in all of the indices except for the L/N(max) for glioma. ROC analysis indicated that the L/N(mean) was the most informative index for differentiating between tumor recurrence and radiation necrosis. An L/N(mean) of greater than 1.41 provided the best sensitivity and specificity for metastatic brain tumor (79% and 75%, respectively), and an L/N(mean) of greater than 1.58 provided the best sensitivity and specificity for glioma (75% and 75%, respectively). CONCLUSION: (11)C-MET PET can provide quantitative values to aid in the differentiation of tumor recurrence from radiation necrosis, although these values do not appear to be absolute indicators. Quantitative analysis of (11)C-MET PET data may be helpful in managing irradiated brain tumors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Applications of PET in Brain Tumors
Chen, W. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.037689 · Cited by 449
Di Chiro, G., Oldfield, E., Wright, D., De Michele, D., Katz, D., Patronas, N., Doppman, J., Larson, S., Ito, M., & Kufta, C. (1988) · American Journal of Roentgenology · doi:10.2214/ajr.150.1.189 · Cited by 422
Chen, W., Silverman, D. H. S., Delaloye, S., Czernin, J. G., Kamdar, N. V., Pope, W. B., Satyamurthy, N., Schiepers, C. W., & Cloughesy, T. F. (2006) · PubMed · Cited by 407
Patronas, N. J., Di Chiro, G., Brooks, R. A., DeLaPaz, R. L., Kornblith, P. L., Smith, B. H., Rizzoli, H. V., Kessler, R. M., Manning, R. G., Channing, M., et al. (1982) · Radiology · doi:10.1148/radiology.144.4.6981123 · Cited by 298
Valk, P. E., Budinger, T. F., Levin, V. A., Silver, P., Gutin, P. H., & Doyle, W. K. (1988) · Journal of Neurosurgery · doi:10.3171/jns.1988.69.6.0830 · Cited by 218
Positron emission tomography imaging of brain tumors
Wong, T. Z., van der Westhuizen, G. J., & Coleman, R. E. (2002) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(02)00033-3 · Cited by 207
Differentiation of residual or recurrent tumors from post-treatment changes with F-18 FDG PET.
Kim, E. E., Chung, S. K., Haynie, T. P., Kim, C. G., Cho, B. J., Podoloff, D. A., Tilbury, R. S., Yang, D. J., Yung, W. K., & Moser, R. P. (1992) · RadioGraphics · doi:10.1148/radiographics.12.2.1561416 · Cited by 173
Diagnosis of recurrent brain tumor: value of 201Tl SPECT vs 18F-fluorodeoxyglucose PET.
Kahn, D. J., Follett, K. A., Bushnell, D., Nathan, M. A., Piper, J., Madsen, M. T., & Kirchner, P. T. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.6.7992747 · Cited by 158
Outcome and Cost of Craniotomy Performed to Treat Tumors in Regional Academic Referral Centers
Long, D. M., Gordon, T. A., Bowman, H. M., Etzel, A., Burleyson, G. P., Betchen, S. A., Garonzik, I. M., & Brem, H. (2003) · Neurosurgery · doi:10.1227/01.neu.0000057745.48813.93 · Cited by 112
Bělohlávek, O., Šimonová, G., Kantorová, I., Novotný, J., & Liščák, R. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1011-2 · Cited by 96
Cited by
van den Bent, M., Wefel, J., Schiff, D., Taphoorn, M., Jaeckle, K., Junck, L., Armstrong, T., Choucair, A., Waldman, A., Gorlia, T., et al. (2011) · The Lancet Oncology · doi:10.1016/s1470-2045(11)70057-2 · Cited by 645
Law, I., Albert, N. L., Arbizu, J., Boellaard, R., Drzezga, A., Galldiks, N., la Fougère, C., Langen, K.-J., Lopci, E., Lowe, V., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4207-9 · Cited by 556
Zhou, J., Tryggestad, E., Wen, Z., Lal, B., Zhou, T., Grossman, R., Wang, S., Yan, K., Fu, D.-X., Ford, E., et al. (2011) · Nature Medicine · doi:10.1038/nm.2268 · Cited by 526
Hu, L. S., Baxter, L. C., Smith, K. A., Feuerstein, B. G., Karis, J. P., Eschbacher, J. M., Coons, S. W., Nakaji, P., Yeh, R. F., Debbins, J., et al. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1377 · Cited by 396
Pseudoprogression and pseudoresponse in the treatment of gliomas
Brandsma, D., & van den Bent, M. J. (2009) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328332363e · Cited by 378
Advanced MRI and PET imaging for assessment of treatment response in patients with gliomas
Dhermain, F. G., Hau, P., Lanfermann, H., Jacobs, A. H., & van den Bent, M. J. (2010) · The Lancet Neurology · doi:10.1016/s1474-4422(10)70181-2 · Cited by 368
Verma, N., Cowperthwaite, M. C., Burnett, M. G., & Markey, M. K. (2013) · Neuro-Oncology · doi:10.1093/neuonc/nos307 · Cited by 351
Advances in neuro-oncology imaging
Langen, K.-J., Galldiks, N., Hattingen, E., & Shah, N. J. (2017) · Nature Reviews Neurology · doi:10.1038/nrneurol.2017.44 · Cited by 339
Value of 11C-methionine PET in imaging brain tumours and metastases
Glaudemans, A. W. J. M., Enting, R. H., Heesters, M. A. A. M., Dierckx, R. A. J. O., van Rheenen, R. W. J., Walenkamp, A. M. E., & Slart, R. H. J. A. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2295-5 · Cited by 286
Molecular imaging of gliomas with PET: Opportunities and limitations
la Fougere, C., Suchorska, B., Bartenstein, P., Kreth, F.-W., & Tonn, J.-C. (2011) · Neuro-Oncology · doi:10.1093/neuonc/nor054 · Cited by 274
The Diagnosis and Treatment of Pseudoprogression, Radiation Necrosis and Brain Tumor Recurrence
Parvez, K., Parvez, A., & Zadeh, G. (2014) · International Journal of Molecular Sciences · doi:10.3390/ijms150711832 · Cited by 229
“However there are limitations that can arise during interpretation of FDG-PET, such as differentiation from normal cortical uptake, and hence why amino acid analogs such as F-DOPA and C-MET may be more suitable for tumor recurrence [58,59].”
BackgroundBrain metastases: neuroimaging
(2018) · Handbook of Clinical Neurology · doi:10.1016/b978-0-12-811161-1.00007-4 · Cited by 223
“MET PET shows higher uptake in metastases compared to radiation necrosis, with a sensitivity of 79% and specificity of 75% (Terakawa et al., 2008).”
BackgroundZikou, A., Sioka, C., Alexiou, G. A., Fotopoulos, A., Voulgaris, S., & Argyropoulou, M. I. (2018) · Contrast Media & Molecular Imaging · doi:10.1155/2018/6828396 · Cited by 207
“A limitation of (11)C-MET is the need for an on-site cyclotron due to short half life of (11)C, making widespread use of this tracer difficult [34].”
BackgroundGalldiks, N., Stoffels, G., Filss, C. P., Piroth, M. D., Sabel, M., Ruge, M. I., Herzog, H., Shah, N. J., Fink, G. R., Coenen, H. H., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103325 · Cited by 190
“41, with a sensitivity and specificity of 75% and 78%, respectively (7).”
BackgroundResultInfluentialPseudoprogression and pseudoresponse: Challenges in brain tumor imaging
Clarke, J. L., & Chang, S. (2009) · Current Neurology and Neuroscience Reports · doi:10.1007/s11910-009-0035-4 · Cited by 170
“Terakawa et al. [ 19 ] evaluated PET using 11 Cmethionine, an amino acid analogue, and found it to have a sensitivity and specifi city of about 75% each.”
MethodHerholz, K., Langen, K.-J., Schiepers, C., & Mountz, J. M. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2012.06.001 · Cited by 164
Kim, Y. H., Oh, S. W., Lim, Y. J., Park, C.-K., Lee, S.-H., Kang, K. W., Jung, H.-W., & Chang, K. H. (2010) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2010.06.005 · Cited by 158
Developing biomarker-specific end points in lung cancer clinical trials
Neal, J. W., Gainor, J. F., & Shaw, A. T. (2015) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2014.222 · Cited by 51
Sonni, I., Garibotto, V., Iagaru, A., Das, D., & Massoud, T. (2018) · PET/MRI in Oncology · doi:10.1007/978-3-319-68517-5_11 · Cited by 3
Metadata
- Authors
- Terakawa, Y., Tsuyuguchi, N., Iwai, Y., Yamanaka, K., Higashiyama, S., Takami, T., & Ohata, K.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-04-15
- Volume
- 49
- Issue
- 5
- Pages
- 694-699
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2163634369
- Cited by
- 419
- References
- 10
- FWCI
- 14.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.