Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

18F-EF5: A New PET Tracer for Imaging Hypoxia in Head and Neck Cancer

Open access
Komar, Gaber, Seppänen, Marko, Eskola, Olli, Lindholm, Paula, Grönroos, Tove J., Forsback, Sarita, Sipilä, Hannu, Evans, Sydney M., Solin, Olof, Minn, Heikki·2008·Journal of Nuclear Medicine

Abstract

UNLABELLED: The aim of this study was to evaluate 2-(2-nitro-(1)H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl)-acetamide (EF5) labeled with (18)F-fluorine to image hypoxia in patients with squamous cell carcinoma of the head and neck (HNSCC). METHODS: Fifteen patients with HNSCC were studied. Measurement of tumor blood flow was followed by an (18)F-EF5 PET/CT scan. On a separate day, (18)F-FDG PET/CT was performed to determine the metabolically active tumor volume. In 6 patients, dynamic (18)F-EF5 images of the head and neck area were acquired, followed by static images acquired at 1, 2, and 3 h after injection. In the remaining 9 patients, only static images were obtained. (18)F-EF5 uptake in tumors was compared with that in neck muscle, and the (18)F-EF5 findings were correlated with the (18)F-FDG PET/CT studies. RESULTS: A total of 13 primary tumors and 5 lymph node metastases were evaluated for their uptake of (18)F-EF5. The median tumor-to-muscle (18)F-EF5 uptake ratio (T/M) increased over time and was 1.38 (range, 1.1-3.2) 3 h after tracer injection. The median blood flow in tumors was 36.7 mL/100 g/min (range, 23.3-78.6 mL/100 g/min). Voxel-by-voxel analysis of coregistered blood flow and (18)F-EF5 images revealed a distinct pattern, resulting in a T/M of 1.5 at 3 h to be chosen as a cutoff for clinically significant hypoxia. Fourteen of 18 tumors (78%) had subvolumes within the metabolically active tumor volumes with T/M greater than or equal to 1.5. CONCLUSION: On the basis of these data, the potential of (18)F-EF5 to detect hypoxia in HNSCC is encouraging. Further development of (18)F-EF5 for eventual targeting of antihypoxia therapies is warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.108.053785

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 181

Metadata

Authors
Komar, G., Seppänen, M., Eskola, O., Lindholm, P., Grönroos, T. J., Forsback, S., Sipilä, H., Evans, S. M., Solin, O., & Minn, H.
Venue
Journal of Nuclear Medicine
Published
2008-11-07
Volume
49
Issue
12
Pages
1944-1951
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2147216681
Cited by
181
References
3
FWCI
12.90
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 18F-EF5: A New PET Tracer for Imaging Hypoxia in Head and Neck Cancer. https://app.cochat.ai/papers/10.2967/jnumed.108.053785
The paper
Komar, G., Seppänen, M., Eskola, O., Lindholm, P., Grönroos, T. J., Forsback, S., Sipilä, H., Evans, S. M., Solin, O., & Minn, H. (2008). 18F-EF5: A New PET Tracer for Imaging Hypoxia in Head and Neck Cancer. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.108.053785

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.