UNLABELLED: The serotonin (5-hydroxytryptamine, or 5-HT) type 1A receptor (5-HT(1A)R) is implicated in the pathophysiology of numerous neuropsychiatric disorders. We have published the initial evaluation and reproducibility in vivo of [O-methyl-(11)C]2-(4-(4-(2-methoxyphenyl)piperazin-1-yl)butyl)-4-methyl-1,2,4-triazine-3,5(2H,4H)dione ((11)C-CUMI-101), a novel 5-HT(1A) agonist radiotracer, in Papio anubis. Here, we report the optimal modeling parameters of (11)C-CUMI-101 for human PET studies. METHODS: PET scans were obtained for 7 adult human volunteers. (11)C-CUMI-101 was injected as an intravenous bolus, and emission data were collected for 120 min in 3-dimensional mode. We evaluated 10 different models using metabolite-corrected arterial input functions or reference region approaches and several outcome measures. RESULTS: When using binding potential (BP(F) = B(avail)/K(D) [total available receptor concentration divided by the equilibrium dissociation constant]) as the outcome measure, the likelihood estimation in the graphical analysis (LEGA) model performed slightly better than the other methods evaluated at full scan duration. The average test-retest percentage difference was 9.90% ± 5.60%. When using BP(ND) (BP(ND) = f(nd) × B(avail)/K(D); BP(ND) equals the product of BP(F) and f(nd) [free fraction in the nondisplaceable compartment]), the simplified reference tissue method (SRTM) achieved the lowest percentage difference and smallest bias when compared with nondisplaceable binding potential obtained from LEGA using the metabolite-corrected plasma input function (r(2) = 0.99; slope = 0.92). The time-stability analysis indicates that a 120-min scan is sufficient for the stable estimation of outcome measures. Voxel results were comparable to region-of-interest-based analysis, with higher spatial resolution. CONCLUSION: On the basis of its measurable and stable free fraction, high affinity and selectivity, good blood-brain barrier permeability, and plasma and brain kinetics, (11)C-CUMI-101 is suitable for the imaging of high-affinity 5-HT(1A) binding in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.110.076257

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 83

Metadata

Authors
Milak, M. S., DeLorenzo, C., Zanderigo, F., Prabhakaran, J., Kumar, J. S. D., Majo, V. J., Mann, J. J., & Parsey, R. V.
Venue
Journal of Nuclear Medicine
Published
2010-11-23
Volume
51
Issue
12
Pages
1892-1900
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2139351430
Cited by
83
References
2
FWCI
2.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: In Vivo Quantification of Human Serotonin 1A Receptor Using11C-CUMI-101, an Agonist PET Radiotracer. https://app.cochat.ai/papers/10.2967/jnumed.110.076257
The paper
Milak, M. S., DeLorenzo, C., Zanderigo, F., Prabhakaran, J., Kumar, J. S. D., Majo, V. J., Mann, J. J., & Parsey, R. V. (2010). In Vivo Quantification of Human Serotonin 1A Receptor Using11C-CUMI-101, an Agonist PET Radiotracer. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.110.076257

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.