The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
MRI-Based Attenuation Correction for Whole-Body PET/MRI: Quantitative Evaluation of Segmentation- and Atlas-Based Methods
Open accessAbstract
UNLABELLED: PET/MRI is an emerging dual-modality imaging technology that requires new approaches to PET attenuation correction (AC). We assessed 2 algorithms for whole-body MRI-based AC (MRAC): a basic MR image segmentation algorithm and a method based on atlas registration and pattern recognition (AT&PR). METHODS: Eleven patients each underwent a whole-body PET/CT study and a separate multibed whole-body MRI study. The MR image segmentation algorithm uses a combination of image thresholds, Dixon fat-water segmentation, and component analysis to detect the lungs. MR images are segmented into 5 tissue classes (not including bone), and each class is assigned a default linear attenuation value. The AT&PR algorithm uses a database of previously aligned pairs of MRI/CT image volumes. For each patient, these pairs are registered to the patient MRI volume, and machine-learning techniques are used to predict attenuation values on a continuous scale. MRAC methods are compared via the quantitative analysis of AC PET images using volumes of interest in normal organs and on lesions. We assume the PET/CT values after CT-based AC to be the reference standard. RESULTS: In regions of normal physiologic uptake, the average error of the mean standardized uptake value was 14.1% ± 10.2% and 7.7% ± 8.4% for the segmentation and the AT&PR methods, respectively. Lesion-based errors were 7.5% ± 7.9% for the segmentation method and 5.7% ± 4.7% for the AT&PR method. CONCLUSION: The MRAC method using AT&PR provided better overall PET quantification accuracy than the basic MR image segmentation approach. This better quantification was due to the significantly reduced volume of errors made regarding volumes of interest within or near bones and the slightly reduced volume of errors made regarding areas outside the lungs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Gaussian Processes for Machine Learning (Adaptive Computation and Machine Learning)
Rasmussen, C. E., & Williams, C. K. I. (2005) · The MIT Press eBooks · Cited by 1,829
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Self-citationA Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
Self-citationMRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Self-citationCombined PET/MRI: a new dimension in whole-body oncology imaging?
Antoch, G., & Bockisch, A. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0951-6 · Cited by 250
Zaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233
Flows of diffeomorphisms for multimodal image registration
Chefd'hotel, C., Hermosillo, G., & Faugeras, O. (2003) · Proceedings IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2002.1029367 · Cited by 174
Impact of metallic dental implants on CT-based attenuation correction in a combined PET/CT scanner
Kamel, E. M., Burger, C., Buck, A., von Schulthess, G. K., & Goerres, G. W. (2003) · European Radiology · doi:10.1007/s00330-002-1564-2 · Cited by 163
Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
Delso, G., Martínez-Möller, A., Bundschuh, R. A., Ladebeck, R., Candidus, Y., Faul, D. D., & Ziegler, S. I. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/011 · Cited by 118
Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation
Ray, N., Acton, S. T., Altes, T. A., de Lange, E. E., & Brookeman, J. R. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.808354 · Cited by 118
MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
Beyer, T., Weigert, M., Quick, H. H., Pietrzyk, U., VOGT, F. M., Palm, C., Antoch, G., Müller, S. P., & Bockisch, A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0734-0 · Cited by 102
Self-citationMR-based attenuation correction for a whole-body sequential PET/MR system
Hu, Z., Ojha, N., Renisch, S., Schulz, V., Torres, I., Buhl, A., Pal, D., Muswick, G. J., Penatzer, J., Guo, T., et al. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5401802 · Cited by 69
Brechtel, K., Klein, M., Vogel, M. N., Mueller, M., Aschoff, P., Beyer, T., Eschmann, S. M., Bares, R., Claussen, C. D., & Pfannenberg, A. C. (2006) · PubMed · Cited by 60
Self-citationThe effect of patient positioning aids on PET quantification in PET/MR imaging
Mantlik, F., Hofmann, M., Werner, M. K., Sauter, A. W., Kupferschläger, J., Schölkopf, B., Pichler, B. J., & Beyer, T. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1721-9 · Cited by 39
Self-citationThree-region MRI-based whole-body attenuation correction for automated PET reconstruction
Steinberg, J. D., Jia, G., Sammet, S., Zhang, J., Hall, N. C., & Knopp, M. V. (2009) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2009.11.002 · Cited by 38
Image Registration of Structural and Physiological MR Images of Abnormal Anatomy
Mang, A., Cámara, Ó., Caseiras, G. B., Crum, W. R., Schnabel, J. A., Buzug, T. M., Thornton, J. S., Jäger, H. R., & Hawkes, D. J. (2007) · Springer eBooks · doi:10.1007/978-3-540-68764-1_35 · Cited by 24
MR-based attenuation correction for whole-body PET/MR system
Hu, Z., Renisch, S., Schweizer, B., Blaffert, T., Ojha, N., Guo, T., Tang, J., Tung, C., Kaste, J., Schulz, V., et al. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874153 · Cited by 20
Cited by
Ea-GANs: Edge-Aware Generative Adversarial Networks for Cross-Modality MR Image Synthesis
Yu, B., Zhou, L., Wang, L., Shi, Y., Fripp, J., & Bourgeat, P. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2895894 · Cited by 298
PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging
Vandenberghe, S., & Marsden, P. K. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/4/r115 · Cited by 258
Samarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251
Unsupervised MR-to-CT Synthesis Using Structure-Constrained CycleGAN
Yang, H., Sun, J., Carass, A., Zhao, C., Lee, J., Prince, J. L., & Xu, Z. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3015379 · Cited by 204
Mehranian, A., Arabi, H., & Zaidi, H. (2016) · Medical Physics · doi:10.1118/1.4941014 · Cited by 152
Metadata
- Authors
- Hofmann, M., Bezrukov, I., Mantlik, F., Aschoff, P., Steinke, F., Beyer, T., Pichler, B. J., & Schölkopf, B.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2011-08-09
- Volume
- 52
- Issue
- 9
- Pages
- 1392-1399
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2110966329
- Cited by
- 288
- References
- 24
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.