Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Compliance with radiobiologic principles of radionuclide internal dosimetry is fundamental to the success of (90)Y radioembolization. The artery-specific SPECT/CT partition model is an image-guided personalized predictive dosimetric technique developed by our institution, integrating catheter-directed CT hepatic angiography (CTHA), (99m)Tc-macroaggregated albumin SPECT/CT, and partition modeling for unified dosimetry. Catheter-directed CTHA accurately delineates planning target volumes. SPECT/CT tomographically evaluates (99m)Tc-macroaggregated albumin hepatic biodistribution. The partition model is validated for (90)Y resin microspheres based on MIRD macrodosimetry. METHODS: This was a retrospective analysis of our early clinical outcomes for inoperable hepatocellular carcinoma. Mapping hepatic angiography was performed according to standard technique with the addition of catheter-directed CTHA. (99m)Tc-MAA planar scintigraphy was used for liver-to-lung shunt estimation, and SPECT/CT was used for liver dosimetry. Artery-specific SPECT/CT partition modeling was planned by experienced nuclear medicine physicians. RESULTS: From January to May 2011, 20 arterial territories were treated in 10 hepatocellular carcinoma patients. Median follow-up was 21 wk (95% confidence interval [CI], 12-50 wk). When analyzed strictly as brachytherapy, (90)Y radioembolization planned by predictive dosimetry achieved index tumor regression in 8 of 8 patients, with a median size decrease of 58% (95% CI, 40%-72%). Tumor thrombosis regressed or remained stable in 3 of 4 patients with baseline involvement. The best α-fetoprotein reduction ranged from 32% to 95%. Clinical success was achieved in 7 of 8 patients, including 2 by sublesional dosimetry, in 1 of whom there was radioembolization lobectomy intent. Median predicted mean radiation absorbed doses were 106 Gy (95% CI, 105-146 Gy) to tumor, 27 Gy (95% CI, 22-33 Gy) to nontumorous liver, and 2 Gy (95% CI, 1.3-7.3 Gy) to lungs. Across all patients, tumor, nontumorous liver, and lungs received predicted ≥91 Gy, ≤51 Gy, and ≤16 Gy, respectively, via at least 1 target arterial territory. No patients developed significant toxicities within 3 mo after radioembolization. The median time to best imaging response was 76 d (95% CI, 55-114 d). Median time to progression and overall survival were not reached. SPECT/CT-derived mean tumor-to-normal liver ratios varied widely across all planning target volumes (median, 5.4; 95% CI, 4.1-6.7), even within the same patient. CONCLUSION: Image-guided personalized predictive dosimetry by artery-specific SPECT/CT partition modeling achieves high clinical success rates for safe and effective (90)Y radioembolization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Salem, R., Lewandowski, R. J., Mulcahy, M. F., Riaz, A., Ryu, R. K., Ibrahim, S., Atassi, B., Baker, T., Gates, V., Miller, F. H., et al. (2010) · Gastroenterology · doi:10.1053/j.gastro.2009.09.006 · Cited by 1,074
Salem, R., & Thurston, K. G. (2006) · Journal of Vascular and Interventional Radiology · doi:10.1097/01.rvi.0000233785.75257.9a · Cited by 724
van Hazel, G., Blackwell, A., Anderson, J., Price, D., Moroz, P., Bower, G., CARDACI, G. T., & Gray, B. N. (2004) · Journal of Surgical Oncology · doi:10.1002/jso.20141 · Cited by 442
Ho, S., Lau, W. Y., Leung, T. W. T., Chan, M., Ngar, Y. K., Johnson, P. J., & Li, A. K. C. (1996) · European Journal of Nuclear Medicine · doi:10.1007/bf01084369 · Cited by 313 · cited 1×
“Based on MIRD macrodosimetry, it partitions the lungs, tumor, and nontumorous liver into separate compartments for radiation dose modeling (24,26).”
BackgroundRadiation Segmentectomy: A Novel Approach to Increase Safety and Efficacy of Radioembolization
Riaz, A., Gates, V. L., Atassi, B., Lewandowski, R. J., Mulcahy, M. F., Ryu, R. K., Sato, K. T., Baker, T., Kulik, L., Gupta, R., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.10.062 · Cited by 262
Ho, S., Lau, W. Y., Leung, T. W. T., Chan, M., Johnson, P. J., & Li, A. K. C. (1997) · European Journal of Nuclear Medicine · doi:10.1007/bf01728766 · Cited by 255
Gaba, R. C., Lewandowski, R. J., Kulik, L., Riaz, A., Ibrahim, S., Mulcahy, M. F., Ryu, R. K., Sato, K. T., Gates, V. L., Abecassis, M. M., et al. (2009) · Annals of Surgical Oncology · doi:10.1245/s10434-009-0454-0 · Cited by 251
Lau, W.-Y., Kennedy, A. S., Kim, Y. H., Lai, H. K., Lee, R.-C., Leung, T. W. T., Liu, C.-S., Salem, R., Sangro, B., Shuter, B., et al. (2012) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.015 · Cited by 217 · cited 4×
“All treatments were planned by a team of experienced nuclear medicine physicians, and the final prescribed mean radiation absorbed doses were guided by published dose–response relationships (5).”
MethodInfluentialResearch Reporting Standards for Radioembolization of Hepatic Malignancies
Salem, R., Lewandowski, R. J., Gates, V. L., Nutting, C. W., Murthy, R., Rose, S. C., Soulen, M. C., Geschwind, J.-F. H., Kulik, L., Kim, Y. H., et al. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2010.10.029 · Cited by 200 · cited 3×
“1), the criteria of the World Health Organization, and the 2-dimensional criteria of the European Association for the Study of the Liver were used to evaluate 90Y radioembolization as a part of comprehensive multimodality therapy for inoperable HCC, without regard to planning target volumes (28,30).”
BackgroundMethodRadioembolization of Liver Tumors With Yttrium-90 Microspheres
Ahmadzadehfar, H., Biersack, H.-J., & Ezziddin, S. (2010) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.11.001 · Cited by 184
Cited by
Radioembolization of Hepatic Lesions from a Radiobiology and Dosimetric Perspective
Cremonesi, M., Chiesa, C., Strigari, L., Ferrari, M., Botta, F., Guerriero, F., De Cicco, C., Bonomo, G., Orsi, F., Bodei, L., et al. (2014) · Frontiers in Oncology · doi:10.3389/fonc.2014.00210 · Cited by 178
“(22) did not find any significant toxicity in 10 patients receiving mean lung absorbed doses lower than 16 Gy.”
BackgroundMethodInfluential(2012) · PubMed · Cited by 74
Metadata
- Authors
- Kao, Y. H., Hock Tan, A. E., Burgmans, M. C., Irani, F. G., Khoo, L. S., Gong Lo, R. H., Tay, K. H., Tan, B. S., Hoe Chow, P. K., Eng Ng, D. C., & Whatt Goh, A. S.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-02-17
- Volume
- 53
- Issue
- 4
- Pages
- 559-566
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2128553182
- Cited by
- 164
- References
- 22
- FWCI
- 11.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization. https://app.cochat.ai/papers/10.2967/jnumed.111.097469
- The paper
- Kao, Y. H., Hock Tan, A. E., Burgmans, M. C., Irani, F. G., Khoo, L. S., Gong Lo, R. H., Tay, K. H., Tan, B. S., Hoe Chow, P. K., Eng Ng, D. C., & Whatt Goh, A. S. (2012). Image-Guided Personalized Predictive Dosimetry by Artery-Specific SPECT/CT Partition Modeling for Safe and Effective 90Y Radioembolization. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.111.097469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.