The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0
Open accessAbstract
Preamble……2 I.Introduction……2 II.Goals……2 III.Definitions……3 IV. Common clinical applications……3 V. Qualifications and responsibilities of personnel (in the United States)……3 1. Physicians……3 1. SPECT/CT cardiac radionuclide imaging……3 2
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACC/AHA/ASNC Guidelines for the Clinical Use of Cardiac Radionuclide Imaging—Executive Summary
Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., Cerqueira, M. D., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.011 · Cited by 1,303 · cited 3×
“The indications and appropriate use criteria for MPI using hybrid devices are the same as for dedicated SPECT or PET scanners and have been previously addressed (1,4).”
BackgroundMethodAnand, D. V., Lim, E., Hopkins, D., Corder, R., Shaw, L. J., Sharp, P., Lipkin, D., & Lahiri, A. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi808 · Cited by 392
Cited by
Dilsizian, V., Bacharach, S. L., Beanlands, R. S., Bergmann, S. R., Delbeke, D., Dorbala, S., Gropler, R. J., Knuuti, J., Schelbert, H. R., & Travin, M. I. (2016) · Journal of Nuclear Cardiology · doi:10.1007/s12350-016-0522-3 · Cited by 612
Self-citationWriting group, Slart, R. H. J. A., Reviewer group, Cardiovascular, M. O. E., Inflammation, M. O. E. I. &., Members of Committees, S. C., Members of Council, P. I. G., Members of, A. S. N. C., & EANM Committee Coordinator (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3973-8 · Cited by 503
Holistic AI analysis of hybrid cardiac perfusion images for mortality prediction
Marcinkiewicz, A. M., Zhang, W., Shanbhag, A., Miller, R. J. H., Lemley, M., Ramirez, G., Buchwald, M., Killekar, A., Kavanagh, P. B., Feher, A., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01526-0 · Cited by 12
“Examplesofpatientsclassi fi edtobeatahigherriskofdeath(withextracardiac structures,notablythelungsandaorta,contributingthemosttomortality)are showninFig.4,SupplementaryFigs.5and6.”
Metadata
- Authors
- Dorbala, S., Di Carli, M. F., Delbeke, D., Abbara, S., DePuey, E. G., Dilsizian, V., Forrester, J., Janowitz, W., Kaufmann, P. A., Mahmarian, J., Moore, S. C., Stabin, M. G., & Shreve, P.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-06-18
- Volume
- 54
- Issue
- 8
- Pages
- 1485-1507
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2088369476
- Cited by
- 232
- References
- 2
- FWCI
- 12.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0. https://app.cochat.ai/papers/10.2967/jnumed.112.105155
- The paper
- Dorbala, S., Di Carli, M. F., Delbeke, D., Abbara, S., DePuey, E. G., Dilsizian, V., Forrester, J., Janowitz, W., Kaufmann, P. A., Mahmarian, J., Moore, S. C., Stabin, M. G., & Shreve, P. (2013). SNMMI/ASNC/SCCT Guideline for Cardiac SPECT/CT and PET/CT 1.0. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.112.105155
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.