The Low Hepatic Toxicity per Gray of 90Y Glass Microspheres Is Linked to Their Transport in the Arterial Tree Favoring a Nonuniform Trapping as Observed in Posttherapy PET Imaging
Open accessAbstract
UNLABELLED: (90)Y resin and glass microsphere liver radioembolizations delivering lobar doses of 70 and 120 Gy, respectively, display hepatic toxicity similar to 40-Gy fractionated external-beam radiotherapy. We investigated how the lower number of glass microspheres could induce a sufficiently nonuniform dose distribution explaining this paradox. METHODS: Microscale dosimetry was assessed in the realistic liver model developed by Gulec et al. but using the Russell's dose deposition kernel. A lattice of hexagonal prisms represented the hepatic lobules. Two hepatic arterial tree models-that is, a fixed-length and a variable-branches length-were used for the microsphere transport. Equal or asymmetric microsphere relative-spreading probability between 2 daughter vessels was assumed. Several 120-Gy liver simulations were performed: periodic simulations, where 1 or 6 glass microspheres were trapped in all and in only 1 of 6 portal tracts, respectively, and random simulations, where glass microsphere trapping assumed an equal probability for all the portal tracts or a variable probability depending on the successions of artery connections leading to the portal tract, both for the 2 arterial tree models. RESULTS: For the 2 uniform simulations, all hepatic structures received at least 100 Gy. The fast decrease of the (90)Y kernel as the inverse of the square of the distance r is counterbalanced by the number of contributing lobules containing microspheres that increases as r(2). The random simulation with equal-spreading probability gave for the less irradiated tissue a lobule dose distribution centered around 103 Gy (full width at half maximum, 20 Gy). The distribution became significantly asymmetric with the 60%-40% relative-spreading probability, with a shift of the maximum from 103 down to 50 Gy, and about 17% of the lobules got a dose lower than 40 Gy to their different structures. CONCLUSION: The large nonuniform trapping produced by the microsphere transport in the arterial tree jointly with the low number of injected glass microspheres begins to explain their lower hepatic toxicity per Gray. In addition, the nonuniform trapping supports the fact that the granular aspect of (90)Y PET imaging observed in patients could represent some reality and not only statistical noise.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Tolerable liver absorbed doses appear higher for microspheres compared with external beam or other beta-emitting therapies, likely because of microscale dosing of 90Y-microspheres, which tends to be nonuniformly distributed throughout the hepatic arterial system/liver, resulting in many areas that receive lower absorbed doses.
“The reason why tolerable liver absorbed doses appear to be higher for microspheres in comparison to external beam or other b -emitting therapies (MIBG; radioimmunotherapies) is likely because of the microscale dosing of 90 Y-microspheres, which tends to be nonuniformly distributed throughout the hepatic arterial system/liver. This results in many areas that receive lower absorbed doses ( 57 ).”
From Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns (2021) · cites this paper as [57]
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Tolerance of normal tissue to therapeutic irradiation
Emami, B., Lyman, J., Brown, A., Cola, L., Goitein, M., Munzenrider, J. E., Shank, B., Solin, L. J., & Wesson, M. (1991) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(91)90171-y · Cited by 4,488 · see citing works
Kennedy, A. S., Nag, S. K., Salem, R., Murthy, R., McEwan, A. J. B., Nutting, C. W., Benson, A. B., Espat, N. J., Bilbao, J. I., Sharma, R. A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.11.060 · Cited by 678 · see citing works
Kennedy, A. S., Nutting, C. W., Coldwell, D. M., et al. (2004) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.09.004 · Cited by 409 · see citing works
A free program for calculating EUD-based NTCP and TCP in external beam radiotherapy
Gay, H. A., & Niemierko, A. (2007) · Physica Medica · doi:10.1016/j.ejmp.2007.07.001 · Cited by 330 · see citing works
Bentzen, S. M., Dörr, W., Gahbauer, R., Howell, R. W., Joiner, M. C., Jones, B., Jones, D. T. L., van der Kogel, A. J., Wambersie, A., & Whitmore, G. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2012.10.006 · Cited by 244 · see citing works
Strigari, L., Sciuto, R., Rea, S., Carpanese, L., Pizzi, G., Soriani, A., Iaccarino, G., Benassi, M., Ettorre, G. M., & Maini, C. L. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.075861 · Cited by 239 · see citing works
Lau, W. Y., Kennedy, A. S., Kim, Y. H., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.015 · Cited by 217 · see citing works
Rapid prototyping as a tool for manufacturing bioartificial livers
Wang, X., Yan, Y., & Zhang, R. (2007) · Trends in biotechnology · doi:10.1016/j.tibtech.2007.08.010 · Cited by 146 · see citing works
Kennedy, A. S., Kleinstreuer, C., Basciano, C. A., et al. (2009) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2009.06.069 · Cited by 94 · see citing works
(2012) · PubMed · Cited by 74 · see citing works
Güleç, S. A., Sztejnberg, M. L., Siegel, J. A., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069278 · Cited by 73 · see citing works
Analysis and Algorithmic Generation of Hepatic Vascular Systems
Schwen, L. O., & Preußer, T. (2012) · International Journal of Hepatology · doi:10.1155/2012/357687 · Cited by 55 · see citing works
Computational Fluid Dynamics Modeling of 90Y Microspheres in Human Hepatic Tumors
Basciano, C. A., Kleinstreuer, C., & Kennedy, A. S. (2011) · Journal of Nuclear Medicine & Radiation Therapy · doi:10.4172/2155-9619.1000112 · Cited by 38 · see citing works
Fast algorithm for 3-D vascular tree modeling
Krętowski, M., Rolland, Y., Bézy‐Wendling, J., et al. (2003) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(01)00200-0 · Cited by 32 · see citing works
Tables of beta-ray dose distributions in water
Cross, W. G., Freedman, N., & Wong, P. (1992) · Cited by 31 · see citing works
Basciano, C. A. (2010) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 20 · see citing works
Paxton, A. B., Davis, S., & DeWerd, L. A. (2012) · Medical Physics · doi:10.1118/1.3685577 · Cited by 8 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Russell JL, Carden JL, Herron HL. Dosimetry calculation for yttrium-90 used in the treatment of liver cancer. Endocuriether Hyperther Oncol. 1988;4:171-186
- Kennedy AS, Nutting C, Coldwell D, Gaiser J, Drachenberg C. Pathologic re- sponse and microscale dosimetry of 90 Y microspheres in man: review of four explanted whole livers. Int J Radiat Oncol Biol Phys. 2004;60:1552-1563.
Cited by
Sorted by citations
Normal-Tissue Tolerance to Radiopharmaceutical Therapies, the Knowns and the Unknowns
Wahl, R. L., Sgouros, G., Iravani, A., Jacene, H., Pryma, D., Saboury, B., Capala, J., & Graves, S. A. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262751 · Cited by 95 · see citing works
- Authors
- Walrand, S., Hesse, M., Chiesa, C., Lhommel, R., & Jamar, F.
- Affiliations
- UCLouvain (BE)
- Fondazione IRCCS Istituto Nazionale dei Tumori (IT)
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-12-02
- Volume
- 55
- Issue
- 1
- Pages
- 135-140
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2152135563
- Cited by
- 99
- References
- 17
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 5 · 2022: 10 · 2021: 12 · 2020: 11 · 2019: 10 · 2018: 7 · 2017: 4 · 2016: 6 · 2015: 9 · 2014: 7
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Nuclear Medicine (publishedVersion)
- PubMed (publishedVersion)
- Digital Access to Libraries (submittedVersion)
- Topics
- Health Sciences › Medicine › Hepatology › Hepatocellular Carcinoma Treatment and Prognosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- yttrium-90 glass microspheres, hepatic radioembolization, hepatotoxicity
- MeSH terms
- Glass, Hepatic Artery, Humans, Liver, Microspheres, Monte Carlo Method, Probability, Radiometry, Radiotherapy Dosage, Yttrium Radioisotopes, Positron-Emission Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review