CoChat

Parametric Imaging and Test–Retest Variability of11C-(+)-PHNO Binding to D2/D3Dopamine Receptors in Humans on the High-Resolution Research Tomograph PET Scanner

Open access
Gallezot, Jean-Dominique, Zheng, Ming-Qiang, Lim, Keunpoong, Lin, Shu-fei, Labaree, David, Matuskey, David, Huang, Yiyun, Ding, Yu-Shin, Carson, Richard E., Malison, Robert T. · 2014 · Journal of Nuclear Medicine
Cited by 55

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

UNLABELLED: (11)C-(+)-4-propyl-9-hydroxynaphthoxazine ((11)C-(+)-PHNO) is an agonist radioligand for imaging dopamine D2 and D3 receptors in the human brain with PET. In this study we evaluated the reproducibility of (11)C-(+)-PHNO binding parameters using a within-day design and assessed parametric imaging methods. METHODS: Repeated studies were performed in 8 subjects, with simultaneous measurement of the arterial input function and plasma free fraction. Two (11)C-(+)-PHNO scans for the same subject were separated by 5.4 ± 0.7 h. After compartment models were evaluated, (11)C-(+)-PHNO volumes of distribution (V(T)) and binding potentials relative to the concentration of tracer in plasma (BP(P)), nondisplaceable tracer in tissue (BP(ND)), and free tracer in tissue (BP(F)) were quantified using the multilinear analysis MA1 method, with the cerebellum as the reference region. Parametric images of BP(ND) were also computed using the simplified reference tissue model (SRTM) and SRTM2. RESULTS: The test-retest variability of (11)C-(+)-PHNO BP(ND) was 9% in D2-rich regions (caudate and putamen). Among D3-rich regions, variability was low in the pallidum (6%) but higher in substantia nigra (19%), thalamus (14%), and hypothalamus (21%). No significant mass carry-over effect was observed in D3-rich regions, although a trend in BP(ND) was present in the substantia nigra (-14% ± 15%). Because of the relatively fast kinetics, low-noise BP(ND) parametric images were obtained with both SRTM and SRTM2 without spatial smoothing. CONCLUSION: (11)C-(+)-PHNO can be used to compute low-noise parametric images in both D2- and D3-rich regions in humans.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.113.132928

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Gallezot, J.-D., Zheng, M.-Q., Lim, K., Lin, S.-F., Labaree, D., Matuskey, D., Huang, Y., Ding, Y.-S., Carson, R. E., & Malison, R. T.
Venue
Journal of Nuclear Medicine
Published
2014-04-14
Volume
55
Issue
6
Pages
960-966
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2129775580
Cited by
55
References
4
FWCI
3.85
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.