CoChat

Standardized Expression of 18F-NAV4694 and 11C-PiB β-Amyloid PET Results with the Centiloid Scale

Open access
Rowe, Christopher C., Jones, Gareth, Doré, Vincent, Pejoska, Svetlana, Margison, Laura, Mulligan, Rachel S., Chan, J. Gordon, Young, Kenneth, Villemagne, Victor L. · 2016 · Journal of Nuclear Medicine
Cited by 140

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

UNLABELLED: A common quantitative output value for PET measures of β-amyloid (Aβ) binding across tracers and methods would allow better comparison of data across sites and application of universal diagnostic and prognostic values. A method has recently been developed that generates a unit of measurement called the centiloid. We applied this method to 2-[2-(18)F-fluoro-6-(methylamino)-3-pyridinyl]-1-benzofuran-5-ol ((18)F-NAV4694) and (11)C-Pittsburgh compound B ((11)C-PiB) Aβ images to derive the scaling factor required to express tracer binding in centiloids. METHODS: Fifty-five participants, including 10 young controls (33 ± 7 y old), underwent both (11)C-PiB and (18)F-NAV4694 imaging no more than 3 mo apart, with the images acquired 50-70 min after tracer injection. The images were spatially normalized and analyzed using the standard centiloid method and regions (cortex and whole-cerebellum reference) downloaded from the Global Alzheimer Association Interactive Network website. RESULTS: SUV ratios (SUVRs) showed a strong correlation in tracer binding ((18)F-NAV4694 SUVR = 1.09 × (11)C-PiB SUVR - 0.08, R(2) = 0.99). The equation to convert (18)F-NAV4694 to centiloids [100 × ((18)F-NAV4694 SUVR - 1.028)/1.174] was similar to a published equation for (11)C-PiB [100 × ((11)C-PiB SUVR - 1.009)/1.067]. In the young controls, the variance ratio ((18)F-NAV4694 centiloid SD divided by (11)C-PiB centiloid SD) was 0.85. CONCLUSION: The results for both (11)C-PiB and (18)F-NAV4694 can now be expressed in centiloids, an important step that should allow better clinical and research use of Aβ imaging. The standard centiloid method also showed that (18)F-NAV4694 has slightly higher Aβ binding and lower variance than (11)C-PiB, important properties for detecting early Aβ deposition and change over time.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.115.171595

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 140

Metadata

Authors
Rowe, C. C., Jones, G., Doré, V., Pejoska, S., Margison, L., Mulligan, R. S., Chan, J. G., Young, K., & Villemagne, V. L.
Venue
Journal of Nuclear Medicine
Published
2016-02-16
Volume
57
Issue
8
Pages
1233-1237
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2298406751
Cited by
140
References
7
FWCI
5.95
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Standardized Expression of 18F-NAV4694 and 11C-PiB β-Amyloid PET Results with the Centiloid Scale. https://app.cochat.ai/papers/10.2967/jnumed.115.171595
The paper
Rowe, C. C., Jones, G., Doré, V., Pejoska, S., Margison, L., Mulligan, R. S., Chan, J. G., Young, K., & Villemagne, V. L. (2016). Standardized Expression of 18F-NAV4694 and 11C-PiB β-Amyloid PET Results with the Centiloid Scale. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.115.171595

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.