The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Prostate Cancer: Interobserver Agreement and Accuracy with the Revised Prostate Imaging Reporting and Data System at Multiparametric MR Imaging
Open accessAbstract
PURPOSE: To evaluate accuracy and interobserver variability with the use of the Prostate Imaging Reporting and Data System (PI-RADS) version 2.0 for detection of prostate cancer at multiparametric magnetic resonance (MR) imaging in a biopsy-naïve patient population. MATERIALS AND METHODS: This retrospective HIPAA-compliant study was approved by the local ethics committee, and written informed consent was obtained from all patients for use of their imaging and histopathologic data in future research studies. In 101 biopsy-naïve patients with elevated prostate-specific antigen levels who underwent multiparametric MR imaging of the prostate and subsequent transrectal ultrasonography (US)-MR imaging fusion-guided biopsy, suspicious lesions detected at multiparametric MR imaging were scored by five readers who were blinded to pathologic results by using to the newly revised PI-RADS and the scoring system developed in-house. Interobserver agreement was evaluated by using κ statistics, and the correlation of pathologic results with each of the two scoring systems was evaluated by using the Kendall τ correlation coefficient. RESULTS: Specimens of 162 lesions in 94 patients were sampled by means of transrectal US-MR imaging fusion biopsy. Results for 87 (54%) lesions were positive for prostate cancer. Kendall τ values with the PI-RADS and the in-house-developed scoring system, respectively, at T2-weighted MR imaging in the peripheral zone were 0.51 and 0.17 and in the transitional zone, 0.45 and -0.11; at diffusion-weighted MR imaging, 0.42 and 0.28; at dynamic contrast material-enhanced MR imaging, 0.23 and 0.24, and overall suspicion scores were 0.42 and 0.49. Median κ scores among all possible pairs of readers for PI-RADS and the in-house-developed scoring system, respectively, for T2-weighted MR images in the peripheral zone were 0.47 and 0.15; transitional zone, 0.37 and 0.07; diffusion-weighted MR imaging, 0.41 and 0.57; dynamic contrast-enhanced MR imaging, 0.48 and 0.41; and overall suspicion scores, 0.46 and 0.55. CONCLUSION: Use of the revised PI-RADS provides moderately reproducible MR imaging scores for detection of clinically relevant disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Self-citationNonparametric Statistical Methods, 2nd, Ed.
Borror, C. M. (2001) · Journal of Quality Technology · doi:10.1080/00224065.2001.11980073 · Cited by 874
Dickinson, L., Ahmed, H. U., Allen, C., Barentsz, J. O., Carey, B., Futterer, J. J., Heijmink, S. W., Hoskin, P. J., Kirkham, A., Padhani, A. R., et al. (2011) · European Urology · doi:10.1016/j.eururo.2010.12.009 · Cited by 737
Türkbey, B., Mani, H., Shah, V. P., Rastinehad, A. R., Bernardo, M., Pohida, T. J., Pang, Y., Daar, D., Benjamin, C. J., McKinney, Y. L., et al. (2011) · The Journal of Urology · doi:10.1016/j.juro.2011.07.013 · Cited by 497
Self-citationPinto, P. A., Chung, P. H., Rastinehad, A. R., Baccala, A. A., Kruecker, J., Benjamin, C. J., Xu, S., Yan, P., Kadoury, S., Chua, C., et al. (2011) · Journal of Urology · doi:10.1016/j.juro.2011.05.078 · Cited by 450
Self-citationHamoen, E. H. J., de Rooij, M., Witjes, J. A., Barentsz, J. O., & Rovers, M. M. (2015) · European Urology · doi:10.1016/j.eururo.2014.10.033 · Cited by 316
Real-time MRI-TRUS fusion for guidance of targeted prostate biopsies
Xu, S., Kruecker, J., Turkbey, B., Glossop, N., Singh, A. K., Choyke, P., Pinto, P., & Wood, B. J. (2008) · Computer Aided Surgery · doi:10.3109/10929080802364645 · Cited by 295
Self-citationRosenkrantz, A. B., Kim, S., Lim, R. P., Hindman, N., Deng, F.-M., Babb, J. S., & Taneja, S. S. (2013) · Radiology · doi:10.1148/radiol.13122233 · Cited by 267
Hoffman, E. B., Sen, P. K., & Weinberg, C. R. (2001) · Biometrika · doi:10.1093/biomet/88.4.1121 · Cited by 263
Marginal Analyses of Clustered Data When Cluster Size Is Informative
Williamson, J. M., Datta, S., & Satten, G. A. (2003) · Biometrics · doi:10.1111/1541-0420.00005 · Cited by 243
Cited by
Barentsz, J. O., Weinreb, J. C., Verma, S., Thoeny, H. C., Tempany, C. M., Shtern, F., Padhani, A. R., Margolis, D., Macura, K. J., Haider, M. A., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.038 · Cited by 547
Self-citationRosenkrantz, A. B., Ginocchio, L. A., Cornfeld, D., Froemming, A. T., Gupta, R. T., Turkbey, B., Westphalen, A. C., Babb, J. S., & Margolis, D. J. (2016) · Radiology · doi:10.1148/radiol.2016152542 · Cited by 501
Self-citationMultiparametric MRI for prostate cancer diagnosis: current status and future directions
Stabile, A., Giganti, F., Rosenkrantz, A. B., Taneja, S. S., Villeirs, G., Gill, I. S., Allen, C., Emberton, M., Moore, C. M., & Kasivisvanathan, V. (2020) · Nature Reviews Urology · doi:10.1038/s41585-019-0212-4 · Cited by 398
Moldovan, P. C., Van den Broeck, T., Sylvester, R., Marconi, L., Bellmunt, J., van den Bergh, R. C. N., Bolla, M., Briers, E., Cumberbatch, M. G., Fossati, N., et al. (2017) · European Urology · doi:10.1016/j.eururo.2017.02.026 · Cited by 391
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2017) · European Urology · doi:10.1016/j.eururo.2017.01.042 · Cited by 308
Metadata
- Authors
- Muller, B. G., Shih, J. H., Sankineni, S., Marko, J., Rais-Bahrami, S., George, A. K., de la Rosette, J. J. M. C. H., Merino, M. J., Wood, B. J., Pinto, P., Choyke, P. L., & Turkbey, B.
- Venue
- Radiology
- Published
- 2015-12
- Volume
- 277
- Issue
- 3
- Pages
- 741-750
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1892627793
- Cited by
- 331
- References
- 15
- FWCI
- 38.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prostate Cancer: Interobserver Agreement and Accuracy with the Revised Prostate Imaging Reporting and Data System at Multiparametric MR Imaging. https://app.cochat.ai/papers/10.1148/radiol.2015142818
- The paper
- Muller, B. G., Shih, J. H., Sankineni, S., Marko, J., Rais-Bahrami, S., George, A. K., de la Rosette, J. J. M. C. H., Merino, M. J., Wood, B. J., Pinto, P., Choyke, P. L., & Turkbey, B. (2015). Prostate Cancer: Interobserver Agreement and Accuracy with the Revised Prostate Imaging Reporting and Data System at Multiparametric MR Imaging. Radiology. https://doi.org/10.1148/radiol.2015142818
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.