CoChat

Kinetic Modeling of the Tau PET Tracer 18F-AV-1451 in Human Healthy Volunteers and Alzheimer Disease Subjects

Open access
Barret, Olivier, Alagille, David, Sanabria, Sandra, Comley, Robert A., Weimer, Robby M., Borroni, Edilio, Mintun, Mark, Seneca, Nicholas, Papin, Caroline, Morley, Thomas, Marek, Ken, Seibyl, John P., Tamagnan, Gilles D., Jennings, Danna · 2017 · Journal of Nuclear Medicine
Cited by 73

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

18F-AV-1451 is currently the most widely used of several experimental tau PET tracers. The objective of this study was to evaluate 18F-AV-1451 binding with full kinetic analysis using a metabolite-corrected arterial input function and to compare parameters derived from kinetic analysis with SUV ratio (SUVR) calculated over different imaging time intervals. Methods:18F-AV-1451 PET brain imaging was completed in 16 subjects: 4 young healthy volunteers (YHV), 4 aged healthy volunteers (AHV), and 8 Alzheimer disease (AD) subjects. Subjects were imaged for 3.5 h, with arterial blood samples obtained throughout. PET data were analyzed using plasma and reference tissue–based methods to estimate the distribution volume, binding potential (BPND), and SUVR. BPND and SUVR were calculated using the cerebellar cortex as a reference region and were compared across the different methods and across the 3 groups (YHV, AHV, and AD). Results: AD demonstrated increased 18F-AV-1451 retention compared with YHV and AHV based on both invasive and noninvasive analyses in cortical regions in which paired helical filament tau accumulation is expected in AD. A correlation of R2 > 0.93 was found between BPND (130 min) and SUVR-1 at all time intervals. Cortical SUVR curves reached a relative plateau around 1.0–1.2 for YHV and AHV by approximately 50 min, but increased in AD by up to approximately 20% at 110–130 min and approximately 30% at 160–180 min relative to 80–100 min. Distribution volume (130 min) was lower by 30%–35% in the YHV than AHV. Conclusion: Our data suggest that although 18F-AV-1451 SUVR curves do not reach a plateau and are still increasing in AD, an SUVR calculated over an imaging window of 80–100 min (as currently used in clinical studies) provides estimates of paired helical filament tau burden in good correlation with BPND, whereas SUVR sensitivity to regional cerebral blood changes needs further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.116.182881

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 73

Metadata

Authors
Barret, O., Alagille, D., Sanabria, S., Comley, R. A., Weimer, R. M., Borroni, E., Mintun, M., Seneca, N., Papin, C., Morley, T., Marek, K., Seibyl, J. P., Tamagnan, G. D., & Jennings, D.
Venue
Journal of Nuclear Medicine
Published
2016-12-01
Volume
58
Issue
7
Pages
1124-1131
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2559092651
Cited by
73
References
7
FWCI
7.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Kinetic Modeling of the Tau PET Tracer 18F-AV-1451 in Human Healthy Volunteers and Alzheimer Disease Subjects. https://app.cochat.ai/papers/10.2967/jnumed.116.182881
The paper
Barret, O., Alagille, D., Sanabria, S., Comley, R. A., Weimer, R. M., Borroni, E., Mintun, M., Seneca, N., Papin, C., Morley, T., Marek, K., Seibyl, J. P., Tamagnan, G. D., & Jennings, D. (2017). Kinetic Modeling of the Tau PET Tracer 18F-AV-1451 in Human Healthy Volunteers and Alzheimer Disease Subjects. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.116.182881

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.