Dose Mapping After Endoradiotherapy with 177Lu-DOTATATE/DOTATOC by a Single Measurement After 4 Days
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Dosimetry of organs and tumors helps to assess risks and benefit of treatment with 177Lu-DOTATATE/DOTATOC. However, it is often not performed in clinical routine because of additional efforts, the complexity of data collection and analysis, and the additional burden for the patients. Aiming at a simplification of dosimetry, we analyzed the accuracy of a theoretically substantiated approximation, which allows the calculation of absorbed doses from a single measurement of the abdominal activity distribution. Methods: Activity kinetics were retrospectively assessed from planar images in 29 patients with neuroendocrine tumors (NETs; n = 21) or meningioma (n = 8) after the administration of 177Lu-DOTATATE (n = 22) or 177Lu-DOTATOC (n = 7). Mono- or biexponential functions were fitted to measured data in 54 kidneys, 25 livers, 27 spleens, and 30 NET lesions. It was evaluated for each fit function how well the integral over time was represented by an approximation calculated as the product of the time tl of a single measurement, the expected reading at time tl, and the factor 2/ln(2). Tissue-specific deviations of the approximation from the time integral were calculated for time points tl of 24, 48, 72, 96, 120, and 144 h. Results: The correlation between time integral and approximation improved with increasing time tl. Pearson r exceeded 0.95 for a tl of 96 h or more in all tissues. The lowest maximum errors were observed at a tl of 96 h, with deviations of the approximation from the time integral of median +5% (range, −9% to +17%) for kidneys, +6% (range, −7% to +12%) for livers, +8% (range, +2% to +20%) for spleens, and +6% (range, −11% to +16%) for NET lesions. Accuracy was reduced for measurements after 72 or 120 h. For measurements after 24, 48, and 144 h, the approximation led to large deviations for some of the patients, in particular unacceptable underestimates of the absorbed dose to the kidneys. Conclusion: A single quantitative measurement of the abdominal activity concentration by SPECT/CT 4 d after the administration of 177Lu-DOTATATE/DOTATOC provides a 3-dimensional dose map and can be used to estimate the doses actually absorbed in the treatment cycle with minor additional resources and effort.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase 3 Trial of 177 Lu-Dotatate for Midgut Neuroendocrine Tumors
Strosberg, J., El-Haddad, G., Wolin, E., Hendifar, A., Yao, J., Chasen, B., Mittra, E., Kunz, P. L., Kulke, M. H., Jacene, H., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1607427 · Cited by 3,308 · cited 3×
“Before the recent publication of the first data from a randomized, controlled, prospective study (NETTER-1) (1), nonrandomized observational studies had already demonstrated the superior overall benefit of PRRT (2–4).”
BackgroundResultInfluentialKwekkeboom, D. J., de Herder, W. W., Kam, B. L., van Eijck, C. H., van Essen, M., Kooij, P. P., Feelders, R. A., van Aken, M. O., & Krenning, E. P. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.15.2553 · Cited by 1,456 · cited 1×
“It was evaluated for each fit function how well the integral over time was represented by an approximation calculated as the product of the time tl of a single measurement, the expected reading at time tl, and the factor 2/ln(2).”
MethodStabin, M. G., Sparks, R. B., & Crowe, E. A. (2005) · PubMed · Cited by 1,350
Bolch, W. E., Eckerman, K. F., Sgouros, G., & Thomas, S. R. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056036 · Cited by 913 · cited 1×
“The total absorbed dose D(rS) to rS by self-irradiation is (17):”
BackgroundZaknun, J. J., Bodei, L., Mueller-Brand, J., Pavel, M. E., Baum, R. P., Hörsch, D., O’Dorisio, M. S., O’Dorisiol, T. M., Howe, J. R., Cremonesi, M., et al. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2330-6 · Cited by 818 · cited 6×
“4 GBq, as used in the NETTER-1 trial, is covered by the recent practical guidance of the European Association of Nuclear Medicine (5).”
MethodInfluentialSiegel, J. A., Thomas, S. R., Stubbs, J. B., Mg, S., Hays, M. T., Koral, K. F., Robertson, J. S., Howell, R. W., Wessels, B. W., Fisher, D. R., et al. (1999) · PubMed · Cited by 572
Bodei, L., Cremonesi, M., Ferrari, M., Pacifici, M., Grana, C. M., Bartolomei, M., Baio, S. M., Sansovini, M., & Paganelli, G. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0778-1 · Cited by 428
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369 · cited 5×
“Phantom measurements indicate that the activity concentration can be quantified by SPECT/CT with 177Lu with uncertainties of 10% or less (13,28).”
BackgroundInfluentialSandström, M., Garske-Román, U., Granberg, D., Johansson, S., Widström, C., Eriksson, B., Sundin, A., Lundqvist, H., & Lubberink, M. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107524 · Cited by 287
Garkavij, M., Nickel, M., Sjögreen‐Gleisner, K., Ljungberg, M., Ohlsson, T., Wingårdh, K., Strand, S., & Tennvall, J. (2010) · Cancer · doi:10.1002/cncr.24796 · Cited by 205 · cited 1×
“However, accuracy of dosimetry from planar scans is limited, and large systematic errors are possible even after careful correction of background, scatter, and attenuation (13,22,25,27).”
BackgroundIndividualized dosimetry in patients undergoing therapy with 177Lu-DOTA-D-Phe1-Tyr3-octreotate
Sandström, M., Garske, U., Granberg, D., Sundin, A., & Lundqvist, H. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1216-8 · Cited by 182 · cited 1×
“However, accuracy of dosimetry from planar scans is limited, and large systematic errors are possible even after careful correction of background, scatter, and attenuation (13,22,25,27).”
BackgroundEsser, J. P., Krenning, E. P., Teunissen, J. J. M., Kooij, P. P. M., van Gameren, A. L. H., Bakker, W. H., & Kwekkeboom, D. J. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0172-9 · Cited by 179
Long-Term Hematotoxicity After Peptide Receptor Radionuclide Therapy with 177Lu-Octreotate
Sabet, A., Ezziddin, K., Pape, U.-F., Ahmadzadehfar, H., Mayer, K., Pöppel, T., Guhlke, S., Biersack, H.-J., & Ezziddin, S. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.119347 · Cited by 163
Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT system
Beauregard, J.-M., Hofman, M. S., Pereira, J. M., Eu, P., & Hicks, R. J. (2011) · Cancer Imaging · doi:10.1102/1470-7330.2011.0012 · Cited by 148 · cited 1×
“Phantom measurements indicate that the activity concentration can be quantified by SPECT/CT with 177Lu with uncertainties of 10% or less (13,28).”
Svensson, J., Berg, G. E. B., Wängberg, B., Larsson, M., Forssell-Aronsson, E. B., & Bernhardt, P. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3001-1 · Cited by 122
Baum, R. P., Kluge, A., Kulkarni, H., Schorr-Neufing, U., Niepsch, K., Bitterlich, N., & van Echteld, C. J. A. (2016) · Theranostics · doi:10.7150/thno.13702 · Cited by 113
Guerriero, F., Ferrari, M. E., Botta, F., Fioroni, F., Grassi, E., Versari, A., Sarnelli, A., Pacilio, M., Amato, E., Strigari, L., et al. (2013) · BioMed Research International · doi:10.1155/2013/935351 · Cited by 111 · cited 2×
“(20) have analyzed the impacts of timing of measurements and the time–activity integration method.”
BackgroundSabet, A., Dautzenberg, K., Haslerud, T. M., Aouf, A., Sabet, A., Simon, B., Mayer, K. T., Biersack, H., & Ezziddin, S. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3041-6 · Cited by 108
Larsson, M., Bernhardt, P., Svensson, J. B., Wängberg, B., Ahlman, H., & Forssell-Aronsson, E. B. (2012) · EJNMMI Research · doi:10.1186/2191-219x-2-49 · Cited by 79 · cited 1×
“However, accuracy of dosimetry from planar scans is limited, and large systematic errors are possible even after careful correction of background, scatter, and attenuation (13,22,25,27).”
BackgroundMinor changes in effective half-life during fractionated177Lu-Octreotate therapy
Garske, U., Sandström, M., Johansson, S., Sundin, A., Granberg, D., Eriksson, B., & Lundqvist, H. (2012) · Acta Oncologica · doi:10.3109/0284186x.2011.618511 · Cited by 68 · cited 1×
“These data are consistent to those reported by others (15,21).”
ResultSvensson, J., Hagmarker, L., Magnander, T., Wängberg, B., & Bernhardt, P. (2016) · EJNMMI Physics · doi:10.1186/s40658-016-0153-4 · Cited by 52
Effect of calculation method on kidney dosimetry in 177Lu-octreotate treatment
Heikkonen, J. J., Mäenpää, H. O., Hippeläinen, E. T., Reijonen, V., & Tenhunen, M. (2016) · Acta Oncologica · doi:10.1080/0284186x.2016.1182642 · Cited by 45 · cited 3×
“These data are consistent to those reported by others (15,21).”
BackgroundResultBaechler, S., Hobbs, R. F., Boubaker, A., Buchegger, F., He, B., Frey, E. C., & Sgouros, G. (2012) · Medical Physics · doi:10.1118/1.4752213 · Cited by 31
Werner, R. A., Beykan, S., Higuchi, T., Lückerath, K., Weich, A., Scheurlen, M., Bluemel, C., Herrmann, K., Buck, A. K., Laßmann, M., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.9775 · Cited by 23
Self-citation
Cited by
EANM procedure guidelines for radionuclide therapy with 177Lu-labelled PSMA-ligands (177Lu-PSMA-RLT)
Kratochwil, C., Fendler, W. P., Eiber, M., Baum, R., Bozkurt, M. F., Czernin, J., Delgado Bolton, R. C., Ezziddin, S., Forrer, F., Hicks, R. J., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04485-3 · Cited by 387
Self-citationSjögreen Gleisner, K., Chouin, N., Gabina, P. M., Cicone, F., Gnesin, S., Stokke, C., Konijnenberg, M., Cremonesi, M., Verburg, F. A., Bernhardt, P., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05727-7 · Cited by 252
Del Prete, M., Buteau, F.-A., Arsenault, F., Saighi, N., Bouchard, L.-O., Beaulieu, A., & Beauregard, J.-M. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4209-7 · Cited by 184
Peters, S. M. B., Privé, B. M., de Bakker, M., de Lange, F., Jentzen, W., Eek, A., Muselaers, C. H. J., Mehra, N., Witjes, J. A., Gotthardt, M., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05471-4 · Cited by 88
“Additional cycles could then be evaluated by acquiring a SPECT/ CT at one time point and use kinetical information from the first cycle to estimate the absorbed dose using a simplified approach according to Hänscheid and colleagues [49] (Additional Resource Materials S2).”
Method
Metadata
- Authors
- Hänscheid, H., Lapa, C., Buck, A. K., Lassmann, M., & Werner, R. A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2017-06-06
- Volume
- 59
- Issue
- 1
- Pages
- 75-81
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2622435004
- Cited by
- 219
- References
- 24
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).