The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Lesion Detection and Interobserver Agreement with Advanced Image Reconstruction for 18 F-DCFPyL PET/CT in Patients with Biochemically Recurrent Prostate Cancer
Open accessAbstract
Biochemically recurrent prostate cancer (BCR) is the main indication to perform prostate-specific membrane antigen PET/CT. However, localizing BCR with prostate-specific membrane antigen PET/CT remains challenging in patients with low prostate-specific antigen (PSA) values. Here, we studied the impact of advanced PET image reconstruction methods on BCR localization and interobserver agreement with 18F-DCFPyL PET/CT scans in patients with BCR and low PSA values. Methods: Twenty-four patients with BCR and a PSA level of less than 2.0 ng/mL were included. PET images were reconstructed with 4-mm voxels and 2-mm voxels, both with and without point-spread function. All scans were interpreted by 4 nuclear medicine physicians. Additionally, PET examinations of 5 patients with primary prostate cancer and confirmed absence of lymph node metastases (after lymph node dissection) were included, to assess the risk of introducing false-positive findings when using advanced reconstruction. Calculation of BCR localization rates (scan positivity) was based on consensus among our readers (≥3 readers regarding a scan positive for BCR), as well as the individual scan interpretations of the readers. Results: In the consensus analysis, BCR localization rates were not higher using advanced reconstruction (62.5%–66.7%) than using 4-mm reconstruction (62.5%). On the basis of individual readings, however, more scans were positive using 2-mm reconstruction (74.0%; 95% confidence interval [CI], 65.0%–82.9%) (P = 0.027) and 2-mm reconstruction with point-spread function (75.0%; 95% CI, 66.2%–83.8%) (P = 0.014) than 4-mm reconstruction (65.6%; 95% CI, 56.0%–75.3%). A higher number of lesions was detected on the 2-mm scans (median, 2 lesions; interquartile range, 1–3) than the 4-mm scans (median, 1; interquartile range, 0–3; P = 0.008). The advanced reconstruction methods did not increase interobserver agreement (80.6%–84.7%), compared with the 4-mm scans (75.7%, P = 0.08–0.25). In the patients with primary prostate cancer, an equal number of false-positive lesions was observed among the different reconstruction methods (overall, n = 13). Conclusion: Applying advanced image reconstruction for 18F-DCFPyL PET/CT scans did not increase BCR localization in patients with BCR and low PSA values (reader consensus). Yet, the increased number of positive individual readings may imply that further development of image reconstruction methods holds potential to improve BCR localization. No improved interobserver agreement was observed with advanced reconstruction compared with standard 4-mm reconstruction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Conflicting results were reported by other authors who did not find higher lesion conspicuity or detection rates with PSF in small patient samples.
“Conflicting results were reported by other authors who did not find higher lesion conspicuity or detection rates with PSF in small patient samples [162,164,165].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [165]
The Discussion reports no improved diagnostic results from PSF and notes the limited number of patients; the Conclusion reports no higher BCR localization rate by reader consensus. However, the Discussion also reports more positive individual readings with 2-mm or 2-mm-plus-PSF reconstruction, and the cited passages do not establish a finding about lesion conspicuity. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer incidence and mortality worldwide: Sources, methods and major patterns in GLOBOCAN 2012
Ferlay, J., Soerjomataram, I., Dikshit, R., Eser, S., Mathers, C., Rebelo, M., Parkin, D. M., Forman, D., & Bray, F. (2015) · International Journal of Cancer · doi:10.1002/ijc.29210 · Cited by 28,766
Siegel, R. L., Miller, K. D., & Jemal, A. (2018) · CA A Cancer Journal for Clinicians · doi:10.3322/caac.21442 · Cited by 16,632
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Self-citationCornford, P. A., Joaquim Bellmunt, B., Bolla, M., Briers, E., Santis, M. D., Gross, T., Henry, A. M., Joniau, S., Lam, T. B. L., Mason, M. D., et al. (2016) · European Urology · doi:10.1016/j.eururo.2016.08.002 · Cited by 1,474
Perera, M., Papa, N. P., Christidis, D., Wetherell, D., Hofman, M. S., Murphy, D. G., Bolton, D. M., & Lawrentschuk, N. (2016) · European Urology · doi:10.1016/j.eururo.2016.06.021 · Cited by 1,028
Afshar‐Oromieh, A., Zechmann, C. M., Malcher, A., Eder, M., Eisenhut, M., Linhart, H., Holland‐Letz, T., Hadaschik, B. A., Giesel, F. L., Debus, J., et al. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2525-5 · Cited by 920
Eiber, M., Herrmann, K., Calais, J., Hadaschik, B., Giesel, F. L., Hartenbach, M., Hope, T., Reiter, R., Maurer, T., Weber, W. A., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.198119 · Cited by 626
Giesel, F. L., Hadaschik, B. A., Cardinale, J., Radtke, J. P., Vinsensia, M., Lehnert, W., Kesch, C. V., Tolstov, Y. L., Singer, S., Grabe, N., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3573-4 · Cited by 595
Afshar‐Oromieh, A., Holland‐Letz, T., Giesel, F. L., Kratochwil, C., Mier, W., Haufe, S., Debus, N., Eder, M., Eisenhut, M., Schäfer, M. K.-H., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3711-7 · Cited by 509
Prostate-specific membrane antigen expression as a predictor of prostate cancer progression
Perner, S., Hofer, M. D., Kim, R., Shah, R. B., Li, H., Mӧller, P., Hautmann, R. E., Gschwend, J. E., Kuefer, R., & Rubin, M. A. (2007) · Human Pathology · doi:10.1016/j.humpath.2006.11.012 · Cited by 455
Szabó, Z. R., Mena, E., Rowe, S. P., Plyku, D., Nidal, R., Eisenberger, M. A., Antonarakis, E. S., Fan, H. S., Dannals, R. F., Chen, Y., et al. (2015) · Molecular Imaging and Biology · doi:10.1007/s11307-015-0850-8 · Cited by 442
Chen, Y., Pullambhatla, M., Foss, C. A., Byun, Y., Nimmagadda, S., Senthamizhchelvan, S., Sgouros, G., Mease, R. C., & Pomper, M. G. (2011) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-11-1357 · Cited by 393
Amling, C. L., Bergstralh, E. J., Blute, M. L., Slezak, J. M., & Zincke, H. (2001) · The Journal of Urology · doi:10.1097/00005392-200104000-00020 · Cited by 348
Clinicians are right not to like Cohen's
de Vet, H. C. W., Mokkink, L. B., Terwee, C. B., Hoekstra, O. S., & Knol, D. L. (2013) · BMJ · doi:10.1136/bmj.f2125 · Cited by 251
Self-citationQuantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
Self-citationAkamatsu, G., Ishikawa, K., Mitsumoto, K., Taniguchi, T., Ohya, N., Baba, S., Abe, K., & Sasaki, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103861 · Cited by 206
Emmett, L., van Leeuwen, P. J., Nandurkar, R., Scheltema, M. J. V., Cusick, T., Hruby, G., Kneebone, A. B., Eade, T., Fogarty, G. B., Jagavkar, R., et al. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.196683 · Cited by 186
Dietlein, F., Kobe, C., Neubauer, S., Schmidt, M., Stockter, S., Fischer, T. H., Schomäcker, K., Heidenreich, A., Zlatopolskiy, B. D., Neumaier, B., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.185538 · Cited by 180
Rowe, S. P., Pienta, K. J., Pomper, M. G., & Gorin, M. A. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.195255 · Cited by 170
Rowe, S. P., Gorin, M. A., Allaf, M. E., Pienta, K. J., Tran, P. T., Pomper, M. G., Ross, A. E., & Cho, S. (2016) · Prostate Cancer and Prostatic Diseases · doi:10.1038/pcan.2016.13 · Cited by 142
Lecouvet, F. E., Oprea‐Lager, D. E., Liu, Y., Ost, P., Bidaut, L. M., Collette, L., Deroose, C. M., Goffin, K. E., Herrmann, K., Hoekstra, O. S., et al. (2018) · The Lancet Oncology · doi:10.1016/s1470-2045(18)30571-0 · Cited by 124
Self-citationGrubmüller, B., Baltzer, P., D’Andrea, D., Korn, S. M., Haug, A. R., Hacker, M., Grubmüller, K. H., Goldner, G. M., Wadsak, W., Pfaff, S., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3858-2 · Cited by 119
Iterative image reconstruction using geometrically ordered subsets with list-mode data
Popescu, L. M., Matej, S., & Lewitt, R. M. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466649 · Cited by 103
Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions
Kolthammer, J. A., Su, K., Grover, A., Narayanan, M. V., Jordan, D. W., & Muzic, R. F. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3843 · Cited by 102
Wondergem, M., Jansen, B. H. E., van der Zant, F. M., van der Sluis, T. M., Knol, R. J. J., van Kalmthout, L. W. M., Hoekstra, O. S., van Moorselaar, R. J. A., Oprea‐Lager, D. E., & Vis, A. N. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04385-6 · Cited by 68
Self-citationClinical evaluation of PET image reconstruction using a spatial resolution model
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.11.015 · Cited by 62
Yin, Y., Werner, R. A., Higuchi, T., Lapa, C., Pienta, K. J., Pomper, M. G., Gorin, M. A., & Rowe, S. P. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.217653 · Cited by 48
Burggraaff, C. N., Cornelisse, A. C., Hoekstra, O. S., Lugtenburg, P. J., de Keizer, B., Arens, A. I. J., Celik, F., Huijbregts, J. E., de Vet, H. C. W., & Zijlstra, J. M. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.210807 · Cited by 27
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Influences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
Self-citationRepeatability of Quantitative 18F-DCFPyL PET/CT Measurements in Metastatic Prostate Cancer
Jansen, B. H. E., Cysouw, M. C. F., Vis, A. N., van Moorselaar, R. J. A., Voortman, J., Bodar, Y. J. L., Schober, P. R., Hendrikse, N. H., Hoekstra, O. S., Boellaard, R., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.236075 · Cited by 32
Self-citationSun, J., Lin, Y., Wei, X., Ouyang, J., Huang, Y., & Ling, Z. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.649171 · Cited by 27
Koschel, S. G., Taubman, K., Sutherland, T., Yap, K., Chao, M., Guerrieri, M., Benson, A., Starmans, M., Byrne, G., Ong, G., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05354-8 · Cited by 24
Hagens, M. J., Oprea‐Lager, D. E., Vis, A. N., Wondergem, M., Donswijk, M. L., Meijer, D., Emmett, L., van Leeuwen, P. J., & van der Poel, H. G. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.263139 · Cited by 22
Self-citationMoving the goalposts while scoring―the dilemma posed by new PET technologies
Rogasch, J. M. M., Boellaard, R., Pike, L., Borchmann, P., Johnson, P., Wolf, J., Barrington, S. F., & Kobe, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05403-2 · Cited by 20
Self-citationWang, L., Wang, L., Wang, X., & Wu, D. (2025) · Current Oncology Reports · doi:10.1007/s11912-025-01682-2 · Cited by 18
Hermsen, R., Wedick, E. B. C., Vinken, M., van Kalmthout, L. W. M., Küsters‐Vandevelde, H. V. N., Wijers, C. H. W., Somford, D. M., & van Basten, J. A. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05827-4 · Cited by 18
Lü, Y., Wilson, Z. J., Xu, G., Xu, Z., Pan, T., & Wei, P. (2023) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000004893 · Cited by 3
Bodar, Y. J. L., Koene, B. P. F., Jansen, B. H. E., Cysouw, M. C. F., Meijer, D., Hendrikse, N. H., Vis, A. N., Boellaard, R., & Oprea‐Lager, D. E. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.260232 · Cited by 3
Self-citationHuo, H., Gu, A., Shen, S., Wu, S., Zhang, H., Chen, Z., & Yang, F. (2023) · Research Square · doi:10.21203/rs.3.rs-2811583/v1
Zeng, Y., Chong, W., Ge, Z., Qin, J., Mo, B., Mu, X., & Fu, W. (2026) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-026-03612-z
Metadata
- Authors
- Jansen, B. H. E., Jansen, R. W., Wondergem, M., Srbljin, S., de Klerk, J. M. H., Lissenberg-Witte, B. I., Vis, A. N., van Moorselaar, R. J. A., Boellaard, R., Hoekstra, O. S., & Oprea-Lager, D. E.
- Affiliations
- Amsterdam University Medical Centers (NL)
- Noordwest Ziekenhuisgroep (NL)
- Zaans Medisch Centrum (NL)
- Meander Medisch Centrum (NL)
- ORCID
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-09-03
- Volume
- 61
- Issue
- 2
- Pages
- 210-216
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2971814749
- Cited by
- 12
- References
- 28
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 3 · 2021: 4 · 2020: 1
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Nuclear Medicine (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (submittedVersion, other-oa)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Astellas Pharma, Netherlands
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Urology › Prostate Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Keywords
- biochemically recurrent prostate cancer, 18F-DCFPyL, point spread function, lesion detection, interobserver agreement, false positives, lymph node metastasis, voxel size, consensus reading, false negative rate, false positive rate, diagnostic accuracy, lymph node dissection
- MeSH terms
- Positron Emission Tomography Computed Tomography, Aged, Humans, Image Processing, Computer-Assisted, Lysine, Male, Middle Aged, Prostatic Neoplasms, Urea, Observer Variation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review