First Human Imaging Studies with the EXPLORER Total-Body PET Scanner*
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Within the EXPLORER Consortium, the construction of the world’s first total-body PET/CT scanner has recently been completed. The 194-cm axial field of view of the EXPLORER PET/CT scanner is sufficient to cover, for the first time, the entire human adult body in a single acquisition in more than 99% of the population and allows total-body pharmacokinetic studies with frame durations as short as 1 s. The large increase in sensitivity arising from total-body coverage as well as increased solid angle for detection at any point within the body allows whole-body 18F-FDG PET studies to be acquired with unprecedented count density, improving the signal-to-noise ratio of the resulting images. Alternatively, the sensitivity gain can be used to acquire diagnostic PET images with very small amounts of activity in the field of view (25 MBq, 0.7 mCi or less), with very short acquisition times (∼1 min or less) or at later time points after the tracer’s administration. We report here on the first human imaging studies on the EXPLORER scanner using a range of different protocols that provide initial evidence in support of these claims. These case studies provide the foundation for future carefully controlled trials to quantitatively evaluate the improvements possible through total-body PET imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763 · cited 3×
“These gains could be used either to (1) deliver enhanced image quality, (2) reduce scan time, (3) increase the time window after injection when scanning is possible, (4) reduce dose, or some combination of these.”
BackgroundSelf-citationRadiation exposure of patients undergoing whole-body dual-modality 18F-FDG PET/CT examinations.
Brix, G., Lechel, U., Glatting, G., Ziegler, S. I., Münzing, W., Müller, S. P., & Beyer, T. (2005) · PubMed · Cited by 458
Total-body imaging: Transforming the role of positron emission tomography
Cherry, S. R., Badawi, R. D., Karp, J. S., Moses, W. W., Price, P., & Jones, T. (2017) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6169 · Cited by 251
Self-citationPoon, J. K., Dahlbom, M. L., Moses, W. W., Balakrishnan, K., Wang, W., Cherry, S. R., & Badawi, R. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4077 · Cited by 129
Self-citationAyati, N., Lee, S. T., Zakavi, S. R., Pathmaraj, K., Al-Qatawna, L., Poon, A. M. T., & Scott, A. M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.192203 · Cited by 61
Lv, Y., Lv, X., Liu, W., Judenhofer, M. S., Zwingenberger, A. L., Wisner, E. R., Berg, E., McKenney, S. E., Leung, E. K., Spencer, B. A., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aafc6c · Cited by 52
Self-citation
Cited by
ImmunoPET: Concept, Design, and Applications
Wei, W., Rosenkrans, Z. T., Liu, J., Huang, G., Luo, Q.-Y., & Cai, W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00738 · Cited by 484
Spencer, B. A., Berg, E., Schmall, J. P., Omidvari, N., Leung, E. K., Abdelhafez, Y. G., Tang, S., Deng, Z., Dong, Y., Lv, Y., et al. (2021) · Journal of Nuclear Medicine · doi:10.2967/jnumed.120.250597 · Cited by 403
“demonstrated the capability of performing low-dose imaging (25 MBq of (18)F-FDG), late-time-point imaging (10 h after (18)FFDG injection), fast imaging (,20 s static images), and simultaneous total-body dynamic imaging (25).”
BackgroundSelf-citationState of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Prenosil, G. A., Sari, H., Fürstner, M., Afshar-Oromieh, A., Shi, K., Rominger, A., & Hentschel, M. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.261972 · Cited by 338
Technological advancements in cancer diagnostics: Improvements and limitations
Pulumati, A., Pulumati, A., Dwarakanath, B. S., Verma, A., & Papineni, R. V. L. (2023) · Cancer Reports · doi:10.1002/cnr2.1764 · Cited by 326
Advances in PET imaging of cancer
Schwenck, J., Sonanini, D., Cotton, J. M., Rammensee, H.-G., la Fougère, C., Zender, L., & Pichler, B. J. (2023) · Nature Reviews Cancer · doi:10.1038/s41568-023-00576-4 · Cited by 312
Radiolabelling of nanomaterials for medical imaging and therapy
Pellico, J., Gawne, P. J., & T. M. de Rosales, R. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00384k · Cited by 304
Alberts, I., Hünermund, J.-N., Prenosil, G., Mingels, C., Bohn, K. P., Viscione, M., Sari, H., Vollnberg, B., Shi, K., Afshar-Oromieh, A., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05282-7 · Cited by 286
Roadmap toward the 10 ps time-of-flight PET challenge
Lecoq, P., Morel, C., Prior, J. O., Visvikis, D., Gundacker, S., Auffray, E., Križan, P., Turtos, R. M., Thers, D., Charbon, E., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab9500 · Cited by 258
Total-Body Dynamic Reconstruction and Parametric Imaging on the uEXPLORER
Zhang, X., Xie, Z., Berg, E., Judenhofer, M. S., Liu, W., Xu, T., Ding, Y., Lv, Y., Dong, Y., Deng, Z., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.230565 · Cited by 206
“device built by United Imaging Healthcare, and we use this name to refer to the specific scanner tested in this work) (9).”
BackgroundMethodSelf-citationDimitrakopoulou-Strauss, A., Pan, L., & Sachpekidis, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04843-6 · Cited by 203
Positronium imaging with the novel multiphoton PET scanner
Moskal, P., Dulski, K., Chug, N., Curceanu, C., Czerwiński, E., Dadgar, M., Gajewski, J., Gajos, A., Grudzień, G., Hiesmayr, B. C., et al. (2021) · Science Advances · doi:10.1126/sciadv.abh4394 · Cited by 180
“Recent developments in total-body PET systems ( 4 – 7 ) have significantly enhanced the PET diagnostic specificity to disentangle cancerous, inflamed, and infected tissues ( 8 , 9 ).”
Zhang, Y.-Q., Hu, P.-C., Wu, R.-Z., Gu, Y.-S., Chen, S.-G., Yu, H.-J., Wang, X.-Q., Song, J., & Shi, H.-C. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04823-w · Cited by 123
Self-citationNuclear medicine and molecular imaging advances in the 21st century
Vaz, S. C., Oliveira, F., Herrmann, K., & Veit-Haibach, P. (2020) · The British Journal of Radiology · doi:10.1259/bjr.20200095 · Cited by 86
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Self-citationImproving nanotherapy delivery and action through image-guided systems pharmacology
Ng, T. S. C., Garlin, M. A., Weissleder, R., & Miller, M. A. (2020) · Theranostics · doi:10.7150/thno.37215 · Cited by 60
“Most recently, the development of total body PET/CT systems with sensitivities up to 40 times that of standard clinical PET/CT scanners will allow detection of radio-labeled-NPs for longer time points and at lower concentrations, further providing systemic kinetic information not previously accessible by current clini…”
BackgroundAssessment of Myofascial Trigger Points via Imaging: A Systematic Review
Mazza, D. F., Boutin, R. D., & Chaudhari, A. J. (2021) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001789 · Cited by 59
Role of Artificial Intelligence in Theranostics
Brosch-Lenz, J., Yousefirizi, F., Zukotynski, K., Beauregard, J.-M., Gaudet, V., Saboury, B., Rahmim, A., & Uribe, C. (2021) · PET Clinics · doi:10.1016/j.cpet.2021.06.002 · Cited by 42
Metadata
- Authors
- Badawi, R. D., Shi, H., Hu, P., Chen, S., Xu, T., Price, P. M., Ding, Y., Spencer, B. A., Nardo, L., Liu, W., Bao, J., Jones, T., Li, H., & Cherry, S. R.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2019-02-07
- Volume
- 60
- Issue
- 3
- Pages
- 299-303
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2914020168
- Cited by
- 722
- References
- 6
- FWCI
- 55.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.