Ultra-Low Power High-Input Impedance Subthreshold CMOS Neural Front-End Amplifier
Open accessAbstract
An ultra-low power, voltage-mode front-end amplifier (FEA) for neural applications featuring subthreshold design is presented. This has been a topic of much research in implantable medical prosthetic devices during the past few decades to monitor and treat the neural disorders such as hearing or sight dysfunctions, epilepsy, Parkinson’s disease, paralysis. The FEA performs a critical signal detection operation in neural monitoring systems to ensure the biosignal fidelity. A matched double-MOS feedback technique is used to compensate the input leakage currents generated by low noise amplifier in the form of integrated circuit (IC), which is the primary reason for immense signal leakage in the input bias network. Therefore, this loop topology ensures that FEA maintains high impedance across a wide range of input frequency. The proposed FEA is implemented by using an SK Hynix 0.18 µm CMOS process. This IC consumes 320 nW in the area of 0.016 mm 2 and achieves the input impedance of 44.9 GΩ, and the input-referred noise of 153 nV/Hz 1/2 .
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Cites
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695 · see citing works
Design of Ultra-Low Power Biopotential Amplifiers for Biosignal Acquisition Applications
Zhang, F., Holleman, J. H., & Otis, B. P. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177089 · Cited by 237 · see citing works
A Fully Integrated Neural Recording Amplifier With DC Input Stabilization
Mohseni, P., & Najafi, K. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.824126 · Cited by 173 · see citing works
320-Channel Active Probe for High-Resolution Neuromonitoring and Responsive Neurostimulation
Shulyzki, R., Abdelhalim, K., Bagheri, A., Salam, M. T., Florez, C. M., Velázquez, J. L. P., Carlen, P. L., & Genov, R. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2312552 · Cited by 106 · see citing works
Design of a 75‐nW, 0.5‐V subthreshold complementary metal–oxide–semiconductor operational amplifier
Magnelli, L., Amoroso, F. A., Crupi, F., et al. (2013) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.1898 · Cited by 102 · see citing works
Ultra-low-noise CMOS current preamplifier from DC to 1 MHz
Ferrari, G., Farina, M., Guagliardo, F., Carminati, M., & Sampietro, M. (2009) · Electronics Letters · doi:10.1049/el.2009.2353 · Cited by 60 · see citing works
An Analogue Front-End Model for Developing Neural Spike Sorting Systems
Barsakcioglu, D. Y., Liu, Y., Bhunjun, P., Navajas, J., Eftekhar, A., Jackson, A., Quiroga, R. Q., & Constandinou, T. G. (2014) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2313087 · Cited by 53 · see citing works
A CMOS Power-Efficient Low-Noise Current-Mode Front-End Amplifier for Neural Signal Recording
Wu, C., Chen, W., & Kuo, L.-T. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2256422 · Cited by 40 · see citing works
A High Input Impedance Low Noise Integrated Front-End Amplifier for Neural Monitoring
Zhou, Z., & Warr, P. A. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2525810 · Cited by 32 · see citing works
Demosthenous, A., Pachnis, I., Jiang, D., & Donaldson, N. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2271477 · Cited by 30 · see citing works
Abdi, A., & Cha, H. (2016) · Microelectronics Journal · doi:10.1016/j.mejo.2016.10.013 · Cited by 16 · see citing works
Sung, Y.-S., Chen, W.-M., & Wu, C. (2016) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2016.7527294 · Cited by 12 · see citing works
Back‐gate current neutralisation feedback loop for high‐input impedance neural FEAs
Zhou, Z., & Warr, P. A. (2016) · Electronics Letters · doi:10.1049/el.2016.2178 · Cited by 5 · see citing works
Moghaddam, K. R., & Mohammadi, A. R. (2017) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2017.04.011 · Cited by 5 · see citing works
Subthreshold nano-watt front-end amplifier for wireless ECG applications
Nevalainen, T., Koivisto, T., & Pänkäälä, M. (2014) · doi:10.1109/norchip.2014.7004713 · Cited by 3 · see citing works
Procedure for building a MOS transistor high frequency small-signal model
Borisov, S., & Korotkov, A. S. (2010) · Radioelectronics and Communications Systems · doi:10.3103/s0735272710070034 · Cited by 3 · see citing works
(2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2642798 · Cited by 1 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- Vol. 62 No. 3 (2019)
Cited by
Sorted by citations
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11 · see citing works
- Authors
- Khan, S. R., & Nadeem, I.
- Affiliations
- Heriot-Watt University (GB)
- Chosun University (KR)
- Corresponding author
- Khan, Sadeque Reza
- Nadeem, Iram
- Venue
- Radioelectronics and Communications Systems
- Publisher
- Allerton Press
- Published
- 2019-03
- Volume
- 62
- Issue
- 3
- Pages
- 134-141
- ISSN
- 0735-2727 (ISSN-L)
- 1934-8061
- OpenAlex
- W2940315744
- Cited by
- 5
- References
- 17
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2022: 1 · 2021: 1
- FWCI
- 0.18
- Type
- journal article
- Language
- en
- Open access
- green
- radioelektronika.org
- Licence
- Locations
- Radioelectronics and Communications Systems (publishedVersion)
- The Scientific Issues of Ternopil Volodymyr Hnatiuk National Pedagogical University Series pedagogy (publishedVersion, cc-by)
- Funders
- SK Hynix
- IC Design Education Center
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- subthreshold CMOS, ultra-low power, high input impedance, neuromonitoring, biomedical implants, input-referred noise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review