Cited by 128Heart Rate Variability and Autonomic ControlNeuroscience and Music PerceptionTactile and Sensory Interactions

Enhancement of heartbeat-related brain potentials through cardiac awareness training

Schandry, Rainer, Weitkunat, Rolf·1990·International Journal of Neuroscience

Abstract

Heartbeat synchronous potentials were found to be sensitive to differences in perceptual accuracy. Since heartbeat perception can be improved using appropriate training procedures, increased ability to perceive cardiac performance should also influence heartbeat-related potentials. In the present study, subjects in either of two groups had to press a button immediately after the occurrence of a heartbeat-feedback tone. Whereas the first group was given acoustical heartbeat-feedback throughout the entire training, the second group was provided with tone signals that became fainter during the course of the training phases. The better posttraining performance in heartbeat perception of the group receiving full-intensity feedback was also reflected in the evoked potentials. They differed markedly before and after training, especially between 250 to 400 ms (after the EKG-R-wave), the biggest effect being at Fz and F7. The findings are interpreted as the brain electrical reflection of an increased perception susceptibility to a cardiovascular signal occurring at about 200 ms after the R-wave.

Integrity signals

Registry

Crossref · 10.3109/00207459008986611

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Schandry and Weitkunat (1990) demonstrated that auditory feedback presented 130 ms after the EKG-R wave increased both cardiac accuracy and heartbeat evoked potentials on a subsequent heartbeat perception task, indicating increased interoceptive accuracy in the cardiac domain.

    “Schandry and Weitkunat (1990), for example, demonstrated that auditory feedback presented 130 ms after the EKG-R wave (such that it is perceived in synchrony with the heartbeat) increased both cardiac accuracy, and heartbeat evoked potentials on a subsequent heartbeat perception task, indicating increased interoceptive accuracy in the cardiac domain.”

    From Atypical interoception as a common risk factor for psychopathology: A review (2021) · cites this paper as Schandry and Weitkunat (1990)

Cited by

Sorted by citations

Authors
Schandry, R., & Weitkunat, R.
Affiliations
Ludwig-Maximilians-Universität München (DE)
Venue
International Journal of Neuroscience
Published
1990-01
Volume
53
Issue
2-4
Pages
243-253
ISSN
  • 0020-7454 (ISSN-L)
  • 1543-5245
OpenAlex
W2069897882
Cited by
128
References
0
Citations by year
2026: 3 · 2025: 8 · 2024: 8 · 2023: 3 · 2022: 5 · 2021: 13 · 2020: 14 · 2019: 8 · 2018: 10 · 2017: 8 · 2016: 5 · 2015: 10 · 2014: 6 · 2013: 7 · 2012: 3
FWCI
0.75
Type
journal article
Language
en
Open access
closed
Locations
  • International Journal of Neuroscience (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
Keywords
heartbeat perception, evoked potentials, perceptual accuracy, R wave
MeSH terms
Adult, Brain, Electrocardiography, Electroencephalography, Evoked Potentials, Feedback, Female, Heart Rate, Humans, Male, Self Concept

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review