Validity and Clinical Utility of Sleep Laboratory Criteria for Insomnia
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The sensitivity, specificity, and positive predictive value of two proposed sleep laboratory criteria for the diagnosis of insomnia were evaluated in 375 adults with a primary complaint of insomnia and 150 noninsomniac controls. The two criteria used results in either low sensitivity and moderately strong specificity or high sensitivity and low specificity and, accordingly, in both cases weak positive predictive values (diagnostic accuracy), both for one night and multiple nights of recordings. Further, an empirically optimized criterion also resulted in an unsatisfactory diagnostic accuracy. Finally, the optimized MMPI criteria were superior to optimized sleep criteria in differentiating insomniacs from controls. In conclusion, sleep laboratory recordings provide little relevant information for confirming or excluding the presence of insomnia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE FIRST NIGHT EFFECT: AN EEG STUDYOF SLEEP
Agnew, H. W., Webb, W. B., & Williams, R. L. (1966) · Psychophysiology · doi:10.1111/j.1469-8986.1966.tb02650.x · Cited by 1,147
Predictive Value of a Single Diagnostic Test in Unselected Populations
Vecchio, T. J. (1966) · New England Journal of Medicine · doi:10.1056/nejm196605262742104 · Cited by 941
Biopsychobehavioral correlates of insomnia. IV: Diagnosis based on DSM- III
(1984) · American Journal of Psychiatry · doi:10.1176/ajp.141.3.357 · Cited by 105
Self-citationThe role of polysomnography in the differential diagnosis of chronic insomnia
(1988) · American Journal of Psychiatry · doi:10.1176/ajp.145.3.346 · Cited by 93
Cited by
Vgontzas, A. N., Bixler, E. O., Lin, H.-M., Prolo, P., Mastorakos, G., Vela-Bueno, A., Kales, A., & Chrousos, G. P. (2001) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.86.8.7778 · Cited by 884
Insomnia with objective short sleep duration: The most biologically severe phenotype of the disorder
Vgontzas, A. N., Fernandez-Mendoza, J., Liao, D., & Bixler, E. O. (2013) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2012.09.005 · Cited by 776
Self-citationInsomnia with Objective Short Sleep Duration is Associated with a High Risk for Hypertension
Vgontzas, A. N., Liao, D., Bixler, E. O., Chrousos, G. P., & Vela-Bueno, A. (2009) · Sleep · doi:10.1093/sleep/32.4.491 · Cited by 748
Self-citationSavard, M.-H., Savard, J., Simard, S., & Ivers, H. (2005) · Psycho-Oncology · doi:10.1002/pon.860 · Cited by 449
“The weak ecologic validity of the PSG is an alternative explanation (Bootzin and EngleFriedman, 1981; Vgontzas et al., 1994; Vgontzas et al., 1995; Wohlgemuth et al., 1999).”
BackgroundChronic insomnia and activity of the stress system
Vgontzas, A. N., Tsigos, C., Bixler, E. O., Stratakis, C. A., Zachman, K., Kales, A., Vela-Bueno, A., & Chrousos, G. P. (1998) · Journal of Psychosomatic Research · doi:10.1016/s0022-3999(97)00302-4 · Cited by 401
“Indeed, the degree of sleep disturbance in our insomniac subjects was rather mild, supported by low values of objective sleep disturbance, which, in fact, were markedly lower than the objective sleep disturbance of chronic insomniacs seeking treatment [19].”
BackgroundSelf-citation
Metadata
- Authors
- Vgontzas, A. N., Bixler, E. O., Kales, A., Manfredi, R. L., & Tyson, K.
- Venue
- International Journal of Neuroscience
- Publisher
- Informa UK Limited
- Published
- 1994-01
- Volume
- 77
- Issue
- 1-2
- Pages
- 11-21
- ISSN
- 0020-7454 (ISSN-L)
- 1543-5245
- OpenAlex
- W1993260589
- Cited by
- 37
- References
- 4
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.