Myoglobin in human skeletal muscle
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
An overall procedure for the determination of myoglobin in muscle biopsy specimens by a radioimmunoassay is described. The coefficient of variation in routine analysis averaged 18%. The mean myoglobin content in leg skeletal muscle of 13 females and 18 males was 4.7 mg/g wet weight. There were no sex differences but the levels for elderly subjects (56-80 years) were slightly higher than those observed in younger persons (19-39 years).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of aging on energy-rich phosphagens in human skeletal muscles
Möller, P., Bergström, J., Fürst, P., & Hellström, K. (1980) · Clinical Science · doi:10.1042/cs0580553 · Cited by 90
Self-citation
Cited by
Time course of loss of adaptations after stopping prolonged intense endurance training
Coyle, E. F., Martin, W. H., Sinacore, D. R., Joyner, M. J., Hagberg, J. M., & Holloszy, J. O. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1857 · Cited by 364
“Myoglobin. The myoglobin concentration of the muscle biopsy samples was determined by radioimmunoassay as described by Moller and Sylven ( 17 ).”
MethodThe optimised CO-rebreathing method: a new tool to determine total haemoglobin mass routinely
Schmidt, W., & Prommer, N. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0050-3 · Cited by 335
Mild mitochondrial uncoupling impacts cellular aging in human muscles in vivo
Amara, C. E., Shankland, E. G., Jubrias, S. A., Marcinek, D. J., Kushmerick, M. J., & Conley, K. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610131104 · Cited by 223
Vanderthommen, M., Duteil, S., Wary, C., Raynaud, J. S., Leroy-Willig, A., Crielaard, J. M., & Carlier, P. G. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00887.2001 · Cited by 190
“Our values of [Mb] are comparable to previous determinations in the human calf muscle (5) and in the quadriceps of subjects aged between 19 and 39 yr (31).”
ResultComparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.276.6.r1682 · Cited by 175
“2 mM metHb as the calibration standard indicates that the Mb signal at the end of the exercisecuff experiment is only 50% desaturated (13, 26, 28, 38, 45).”
Method
Metadata
- Authors
- Möller, P., & Sylvén, C.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1981-01
- Volume
- 41
- Issue
- 5
- Pages
- 479-482
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2049696812
- Cited by
- 68
- References
- 1
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.