Cited by 62Cholesterol and Lipid MetabolismMetabolomics and Mass Spectrometry StudiesLipoproteins and Cardiovascular Health

Determination of serum levels of unesterified lathosterol by isotope dilution-mass spectrometry

Lund, E., Sisfontes, L., Reihner, E., Bjorkhem, I.·1989·Scandinavian Journal of Clinical and Laboratory Investigation

Abstract

The synthesis of 2H3-labelled lathosterol is described. This compound was used together with 2H7-labelled cholesterol for simultaneous assay of unesterified lathosterol and cholesterol in serum by isotope dilution-mass spectrometry. After addition of a fixed amount of the two internal standards to a fixed amount of serum (in general 25 μl), the steroids were extracted with chloroform and subjected to Lipidex 5000 chromatography. The fraction containing cholesterol and lathosterol was converted into trimethylsilyl ether and subjected to mass spectrometric analysis with selected monitoring of the ions at m/z 458 (molecular ion of the trimethylsilyl ether derivative of unlabelled cholesterol and lathosterol), m/z 461 (molecular ion of derivative of 2Hrlabelled lathosterol) and m/z 465 (molecular ion of derivative of 2H7-Iabelled cholesterol).Individual standard curves were used for assay of each steroid. Under the conditions employed, the coefficient of variation of the two assays was less than 6%. In different recovery experiments the maximal difference between expected and found values was less than 7%.Using a less accurate method for analysis of lathosterol, we have shown previously that there is a high correlation between the hepatic HMG CoA reductase and the relative concentration of unesterified lathosterol in serum (concentration of lathosterol relative to cholesterol). This was confirmed with the present method and a correlation coefficient of about 0.94 was found between the two parameters. It is concluded that the present method may be suitable for detection of cases with accelerated rate of synthesis of cholesterol.

Integrity signals

Registry

Crossref · 10.3109/00365518909105417

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lund, E., Sisfontes, L., Reihner, E., & Bjorkhem, I.
Affiliations
Karolinska Institutet (SE)
Venue
Scandinavian Journal of Clinical and Laboratory Investigation
Published
1989-01
Volume
49
Issue
2
Pages
165-171
ISSN
  • 0036-5513 (ISSN-L)
  • 1502-7686
OpenAlex
W4232407077
Cited by
62
References
10
Citations by year
2021: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 6 · 2013: 4 · 2012: 1
FWCI
3.80
Type
journal article
Language
en
Open access
closed
Locations
Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Cholesterol and Lipid Metabolism
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
  • Health Sciences › Medicine › Surgery › Lipoproteins and Cardiovascular Health
Keywords
cholesterol, isotope dilution mass spectrometry, internal standard, HMG-CoA reductase, lipid extraction, trimethylsilyl derivatives

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review