Results from a novel ion selective electrode (ISE) for ionized magnesium (Mg2+) correlate well with atomic absorption spectroscopy on aqueous solutions containing from 0.1-3.0 mmol MgCl2/L. Day to day precision (coefficient of variation) of the electrode on protein-based controls is < 4%; aqueous-based controls < 6%. The new ISE is selective for Mg2+ with a selectivity constant for Ca2+ (KMgCa) of 8 x 10(-2). Adding pathophysiologic concentrations of Cd2+, Ca2+, Cu2+, Fe3+, K+, Na+, or Zn2+ to serum and aqueous solutions gave negligible to minimal changes in measured Mg2+. Ligand binding studies in aqueous solution indicate that pathophysiologic concentrations of different anions (e.g. heparin, lactate, bicarbonate, phosphate, acetate and sulfate) bind to Mg2+, effectively reducing its concentration in solution. Likewise, silicon (as either found in Vacuutainer tubes or as chlorosilane) failed to exert any significant effect on measured Mg2+. Addition of Intralipid (up to 500 mg/dL) gave negligible to minimal changes in Mg2+. Mg2+ measurements on whole blood, plasma, and serum for a given human subject's samples are virtually identical, at least within the reference range for Mg2+. Typically, Mg2+ is 71% of TMg, but varies from subject to subject; i.e. Mg2+ cannot be predicted from TMg. Clinical studies revealed that the Mg2+/TMg ratio could be remarkably consistent in sequential samples (e.g., throughout the course of coronary bypass surgery) taken from one patient, but that this ratio could differ dramatically from the ratio in sequential samples taken from another. Mg2+ is held within a narrow range (0.53-0.67 mmol/L) in normal, healthy subjects when compared to TMg (0.70-0.96 mmol/L).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Saris, N.-E. L., Mervaala, E., Karppanen, H., Khawaja, J. A., & Lewenstam, A. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(99)00258-2 · Cited by 1,366
Composition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Self-citationThe effects of magnesium supplementation on exercise performance
Newhouse, I. J., & Finstad, E. W. (2000) · Clinical Journal of Sport Medicine · doi:10.1097/00042752-200007000-00008 · Cited by 90
The effects of magnesium supplementation on exercise performance
FINSTAD, E. W., NEWHOUSE, I. J., LUKASKI, H. C., MCAULIFFE, J. E., & STEWART, C. R. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200103000-00024 · Cited by 51
Metadata
- Authors
- Altura, B. T., Shirey, T. L., Young, C. C., Dellorfano, K., Hiti, J., Welsh, R., Yeh, Q., Barbour, R. L., & Altura, B. M.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1994-01
- Volume
- 54
- Issue
- sup217
- Pages
- 21-36
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W1967322381
- Cited by
- 131
- References
- 0
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of a New Ion Selective Electrode for Ionized Magnesium in Whole Blood, Plasma, Serum, and Aqueous Samples. https://app.cochat.ai/papers/10.3109/00365519409095208
- The paper
- Altura, B. T., Shirey, T. L., Young, C. C., Dellorfano, K., Hiti, J., Welsh, R., Yeh, Q., Barbour, R. L., & Altura, B. M. (1994). Characterization of a New Ion Selective Electrode for Ionized Magnesium in Whole Blood, Plasma, Serum, and Aqueous Samples. Scandinavian Journal of Clinical and Laboratory Investigation. https://doi.org/10.3109/00365519409095208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.