Poly(methyl methacrylate) particulate carriers in drug delivery
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Poly(methyl methacrylate) (PMMA) is one of the most widely explored biomedical materials because of its biocompatibility, and recent publications have shown an increasing interest in its applications as a drug carrier. PMMA-based particulate carriers (PMMA(P)) can be prepared either by polymerization methods or from pre-formed polymer-based techniques. Potential biomedical application of these particles includes their use as adjuvant for vaccines and carrier of many drugs as antibiotics and antioxidants via different routes of administration. Release of drugs from PMMA(P) occurs typically in a biphasic way with an incomplete drug release. To improve release profiles, recent strategies are focusing on increasing polymer hydrophilicity by synthesizing functionalized PMMA microspheres or by formulating PMMA composites with hydrophilic polymers. This review examines the current status of preparation techniques, drug release kinetics, biomedical applications and toxicity of these nano/micro PMMA-based particulate carriers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and comparison of dissolution profiles
Costa, P., & Sousa Lobo, J. M. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00095-1 · Cited by 5,509
Ullmann's Encyclopedia of Industrial Chemistry
(2012) · Choice Reviews Online · doi:10.5860/choice.50-1224 · Cited by 3,049
Polymer nanoparticles: Preparation techniques and size-control parameters
Rao, J. P., & Geckeler, K. E. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.01.001 · Cited by 1,725 · cited 15×
“Also, An et al. (2006) associated microwave methodology with SFEP to prepare monosize, cross-linked PMMA nanoparticles with hydroxyl functional groups in the critical sub-50 nm range.”
BackgroundMethodInfluentialMundargi, R. C., Babu, V. R., Rangaswamy, V., Patel, P., & Aminabhavi, T. M. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.09.013 · Cited by 1,025 · cited 1×
“In the spray-drying technique (Figure 8), particle formation is achieved by atomizing an emulsion into a stream of hot air under vigorous solvent evaporation (Mundargi et al., 2008).”
MethodQuintanar-Guerrero, D., Allémann, E., Fessi, H., & Doelker, E. (1998) · Drug Development and Industrial Pharmacy · doi:10.3109/03639049809108571 · Cited by 589 · cited 1×
“Its usefulness is limited to water-miscible solvents, in which the diffusion rate is enough to produce spontaneous emulsification (Quintanar-Guerrero et al., 1998).”
BackgroundNanoparticles—a historical perspective
KREUTER, J. (2007) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2006.10.021 · Cited by 540 · cited 1×
“In addition, the presence of emulsifiers and the number of micelles do not affect the number of particles formed (Kreuter, 2007).”
BackgroundDrug delivery systems: Advanced technologies potentially applicable in personalized treatments
Coelho, J. F., Ferreira, P. C., Alves, P., Cordeiro, R., Fonseca, A. C., Góis, J. R., & Gil, M. H. (2010) · EPMA Journal · doi:10.1007/s13167-010-0001-x · Cited by 406 · cited 1×
“In addition, PMMA has also been used in the development of nano/microparticles in several biomedical fields (Coelho et al., 2010).”
MethodPłusa, T. (2012) · Journal of Health Policy & Outcomes Research · doi:10.7365/jhpor.2012.1.1 · Cited by 298
Nanoprecipitation of Polymethylmethacrylate by Solvent Shifting:1. Boundaries
Aubry, J., Ganachaud, F., Cohen Addad, J.-P., & Cabane, B. (2009) · Langmuir · doi:10.1021/la803000e · Cited by 290 · cited 1×
“The production of unloaded PMMA nanoparticles by this technique in which water (non-solvent) was added to a solution of PMMA in tetrahydrofuran (THF) or acetone (solvent) has been reported (Aubry et al., 2009).”
MethodSoft Tissue Augmentation With Artecoll: 10-Year History,Indications, Techniques, and Complications
Lemperle, G., Romano, J. J., & Busso, M. (2003) · Dermatologic Surgery · doi:10.1046/j.1524-4725.2003.29140.x · Cited by 227 · cited 1×
“More recently, an improvement of Artecoll consisting of 20% PMMA microspheres (30–40 mm in diameter) suspended in a 3.5% bovine atelocollagen solution, called Artefill , has been approved by the FDA (Lemperle et al., 2003).”
MethodInfluential
Cited by
Sosnik, A., das Neves, J., & Sarmento, B. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.07.010 · Cited by 487
Polymeric nanoparticles: the future of nanomedicine
Banik, B. L., Fattahi, P., & Brown, J. L. (2016) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1364 · Cited by 485
Al-Shalawi, F. D., Mohamed Ariff, A. H., Jung, D.-W., Mohd Ariffin, M. K. A., Seng Kim, C. L., Brabazon, D., & Al-Osaimi, M. O. (2023) · Polymers · doi:10.3390/polym15122601 · Cited by 235
Nguyen, T., Jung, S. H., Lee, M. S., Park, T.-E., Ahn, S.-K., & Kang, J. H. (2019) · Lab on a Chip · doi:10.1039/c9lc00338j · Cited by 77
Metadata
- Authors
- Bettencourt, A., & Almeida, A. J.
- Venue
- Journal of Microencapsulation
- Publisher
- Informa UK Limited
- Published
- 2012-01-18
- Volume
- 29
- Issue
- 4
- Pages
- 353-367
- ISSN
- 0265-2048 (ISSN-L)
- 1464-5246
- OpenAlex
- W2065025122
- Cited by
- 184
- References
- 45
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.