The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic nanoparticle hyperthermia for prostate cancer
Open accessAbstract
Magnetic nanoparticles are increasingly used for clinical applications such as drug delivery, magnetic resonance imaging and magnetic fluid hyperthermia. A novel method of interstitial heating of tumours following direct injection of magnetic nanoparticles has been evaluated in humans in recent clinical trials. In prostate cancer this approach has been investigated in two separate phase I studies, employing magnetic nanoparticle thermotherapy alone and in combination with permanent seed brachytherapy. The feasibility and good tolerability was shown in both trials, using the first prototype of an alternating magnetic field applicator. As with any other heating technique, this novel approach requires specific tools for planning, quality control and thermal monitoring, based on appropriate imaging and modelling techniques. In these first clinical trials a newly developed method for planning and non-invasive calculations of the 3-dimensional temperature distribution based on computed tomography was validated. Limiting factors of the new approach at present are patient discomfort at high magnetic field strengths and irregular intratumoural heat distribution. Until these limitations are overcome and thermoablation can safely be applied as a monotherapy, this treatment modality is being evaluated in combination with irradiation in patients with localised prostate cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The effect of thermotherapy using magnetic nanoparticles on rat malignant glioma
Jordan, A., Scholz, R., Maier-Hauff, K., van Landeghem, F. K. H., Waldoefner, N., Teichgraeber, U., Pinkernelle, J., Bruhn, H., Neumann, F., Thiesen, B., et al. (2006) · Journal of Neuro-Oncology · doi:10.1007/s11060-005-9059-z · Cited by 459
Self-citation
Cited by
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
The big picture on nanomedicine: the state of investigational and approved nanomedicine products
Etheridge, M. L., Campbell, S. A., Erdman, A. G., Haynes, C. L., Wolf, S. M., & McCullough, J. (2013) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2012.05.013 · Cited by 1,088
“Iron oxide particles are used in MR contrast(79,80) and cancer thermal therapies.(75,81) Colloidal gold is being used in systemic delivery of therapeutic biologicals(82) and for cancer thermal therapies.”
Espinosa, A., Di Corato, R., Kolosnjaj-Tabi, J., Flaud, P., Pellegrino, T., & Wilhelm, C. (2016) · ACS Nano · doi:10.1021/acsnano.5b07249 · Cited by 788
Small particles, big impacts: A review of the diverse applications of nanofluids
Taylor, R., Coulombe, S., Otanicar, T., Phelan, P., Gunawan, A., Lv, W., Rosengarten, G., Prasher, R., & Tyagi, H. (2013) · Journal of Applied Physics · doi:10.1063/1.4754271 · Cited by 759
Soenen, S. J., Rivera-Gil, P., Montenegro, J.-M., Parak, W. J., De Smedt, S. C., & Braeckmans, K. (2011) · Nano Today · doi:10.1016/j.nantod.2011.08.001 · Cited by 699
Metadata
- Authors
- Johannsen, M., Thiesen, B., Wust, P., & Jordan, A.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2010-07-23
- Volume
- 26
- Issue
- 8
- Pages
- 790-795
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2103827181
- Cited by
- 469
- References
- 1
- FWCI
- 6.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic nanoparticle hyperthermia for prostate cancer. https://app.cochat.ai/papers/10.3109/02656731003745740
- The paper
- Johannsen, M., Thiesen, B., Wust, P., & Jordan, A. (2010). Magnetic nanoparticle hyperthermia for prostate cancer. International Journal of Hyperthermia. https://doi.org/10.3109/02656731003745740
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.