Effects of Magnetic Fluid Hyperthermia (MFH) on C3H mammary carcinoma in vivo
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Magnetic fluids (MF) have a potential for hyperthermia due to their good power absorption capabilities. Recent in vitro experiments with the so-called 'Magnetic Fluid Hyperthermia (MFH)' have shown that human tumours cells are homogeneously inactivated after AC magnetic field excitation of extracellular MF. The aim of the present study was the evaluation of a high dose MFH on intramuscularly implanted mammary carcinoma of the mouse. The tumours originated from initial in vivo passages of a spontaneous parent tumour. Because of larger variations of tumour growth in this rather primary model, logistic regression of non-averaged volumes was performed for each treatment modality. All growing tumours were randomized 30 days after transplantation (day of treatment) with an overall size distribution between 120-400 mm3. An intratumoural steady state temperature of 47 +/- 1.0 degrees C was maintained for 30 minutes with whole-body AC magnetic fields of 6-12.5 kA/m at 520 kHz. The magnetic fluid was #P6, which is a high biocompatible dextran magnetite. #P6 was given intratumourally (1.5 x 10(-2) mg ferrite/mm3) 20-30 minutes before excitation and was combined with magnetic targeting (50 mT), which yielded a 2.5-fold enhancement of the intratumoural iron concentration. Histological examinations of tumour tissue after intralesional ferrofluid administration alone indicated deep infiltration of the fluid into the carcinoma tissue, but no evidence of tissue damage as compared with untreated controls. In contrast, widespread tumour necrosis was observed after MFH. After application of either dextran or ferrofluid alone (no difference, p = 0.665), tumour growth was slightly delayed in comparison with untreated controls (p < 0.001). In contrast to the good fit of the controls (R = 0.92-0.87), tumour growth after MFH was much more heterogeneous; some tumours showed no evidence for regrowth at 50 days whereas others had grown quite readily. This most probably reflected the critical problem of homogeneity of the intratumoural MF distribution, which was also confirmed qualitatively by Magnetic Resonance Imaging (MRI), heterogeneous pigmentation of MFH treated tumours, and up to 1 degree C differences between temperature probes in the same tumour during AC magnetic field application. However, a quantitative comparison between intratumoural MF-heterogeneity and tumour response could not be performed in this study. Despite these current limitations, the regression analysis of the MFH data yielded a smaller tumour volume of about 1000 mm3 at 50 days growth time in contrast to all three controls. In conclusion, encouraging results have been obtained, which show, that one single high dose MFH is already able to induce local tumour control in many cases within 30 days after treatment. To overcome the uncertainties of intratumoural MF heterogeneity, advanced intralesional application methods are currently under development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Journal of Laboratory and Clinical Medicine
(2003) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(03)00127-6 · Cited by 1,767
Scientific and Clinical Applications of Magnetic Carriers
(1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6 · Cited by 1,032
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Self-citationMagnetite biomineralization in the human brain.
Kirschvink, J. L., Kobayashi-Kirschvink, A., & Woodford, B. J. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.16.7683 · Cited by 614
C.F. Chan, D., B. Kirpotin, D., & A. Bunn, P. (1993) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(93)91113-l · Cited by 319
Gordon, R. T., Hines, J. R., & Gordon, D. (1979) · Medical Hypotheses · doi:10.1016/0306-9877(79)90063-x · Cited by 310
Jordan, A., Wust, P., Scholz, R., Tesche, B., Fähling, H., Mitrovics, T., Vogl, T., Cervós-navarro, J., & Felix, R. (1996) · International Journal of Hyperthermia · doi:10.3109/02656739609027678 · Cited by 259
Self-citationFerrite particles: a superparamagnetic MR contrast agent for the reticuloendothelial system.
Saini, S., Stark, D. D., Hahn, P. F., Wittenberg, J., Brady, T. J., & Ferrucci, J. T. (1987) · Radiology · doi:10.1148/radiology.162.1.3786765 · Cited by 230
Iron oxide nanoparticles for use as an MRI contrast agent: Pharmacokinetics and metabolism
Pouliquen, D., Le Jeune, J. J., Perdrisot, R., Ermias, A., & Jallet, P. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90412-f · Cited by 222
Intracellular labeling of T‐cells with superparamagnetic contrast agents
Yeh, T., Zhang, W., Ildstad, S. T., & Ho, C. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300513 · Cited by 198
Widder, K. J., Senyei, A. E., & Ranney, D. F. (1979) · Advances in Pharmacology · doi:10.1016/s1054-3589(08)60246-x · Cited by 193
Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J. (1992) · Radiology · doi:10.1148/radiology.182.1.1309218 · Cited by 175
Self-citationFerromagnetic Contamination in the Lungs and Other Organs of the Human Body
Cohen, D. (1973) · Science · doi:10.1126/science.180.4087.745 · Cited by 173
Marchal, G., Van Hecke, P., Demaerel, P., Decrop, E., Kennis, C., Baert, A., & van der Schueren, E. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.4.771 · Cited by 122
Development of intra-arterial hyperthermia using a dextran-magnetite complex
Mitsumori, M., Hiraoka, M., Shibata, T., Okuno, Y., Masunaga, S.-I., Koishi, M., Okajima, K., Nagata, Y., Nishimura, Y., Abe, M., et al. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409012371 · Cited by 89
Magnetic Fluid Hyperthermia (MFH)
Jordan, A., Wust, P., Scholz, R., Fähling, H., Krause, J., & FELIX, R. (1997) · Springer eBooks · doi:10.1007/978-1-4757-6482-6_43 · Cited by 68
Self-citationImmunospecific NMR contrast agents
Renshaw, P. F., Owen, C. S., Evans, A. E., & LEIGH, J. S. J. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)91045-3 · Cited by 64
Use of heating rate and specific absorption rate in the hyperthermia clinic
Chou, C. (1990) · International Journal of Hyperthermia · doi:10.3109/02656739009141144 · Cited by 64
Dextran‐magnetite particles: Contrast‐enhanced MRI of blood–brain barrier disruption in a rat model
Bulte, J. W. M., Jonge, M. W. A., Kamman, R. L., Go, K. G., Zuiderveen, F., Blaauw, B., Oosterbaan, J. A., Hauw, T., & de Leij, L. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230203 · Cited by 48
Morimoto, Y., Sugibayashi, K., OKUMURA, M., & Katô, Y. (1980) · Journal of Pharmacobio-Dynamics · doi:10.1248/bpb1978.3.264 · Cited by 41
Dextran magnetite as a liver contrast agent
Magin, R. L., Bacic, G., Niesman, M. R., et al. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910200102 · Cited by 39
Ferromagnetic embolization. Experimental evaluation.
Barry, J. W., Bookstein, J. J., & Alksne, J. F. (1981) · Radiology · doi:10.1148/radiology.138.2.7455113 · Cited by 19
Superparamagnetische Eisenpartikel
Hamm, B., Reichel, M., Vogl, T., Taupitz, M., & Wolf, K. J. (1994) · RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren · doi:10.1055/s-2008-1032372 · Cited by 8
Self-citation
Cited by
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Nanoparticles, Proteins, and Nucleic Acids: Biotechnology Meets Materials Science
Niemeyer, C. M. (2001) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20011119)40:22<4128::aid-anie4128>3.0.co;2-s · Cited by 2,452
Tomographic imaging using the nonlinear response of magnetic particles
Gleich, B., & Weizenecker, J. (2005) · Nature · doi:10.1038/nature03808 · Cited by 2,003
Magnetic nanoparticle design for medical diagnosis and therapy
Mornet, S., Vasseur, S., Grasset, F., & Duguet, E. (2004) · Journal of Materials Chemistry · doi:10.1039/b402025a · Cited by 1,745
Metadata
- Authors
- Jordan, A., Scholz, R., Wust, P., Fähling, H., Krause, J., Wlodarczyk, W., Sander, B., Vogl, T., & Felix, R.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 1997-01
- Volume
- 13
- Issue
- 6
- Pages
- 587-605
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2144837068
- Cited by
- 325
- References
- 23
- FWCI
- 1.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.