The DOI matches its Crossref record.
Blink Rate, Blink Amplitude, and Tear Film Integrity during Dynamic Visual Display Terminal Tasks
Abstract
PURPOSE: The present study aimed at investigating the influence of the level of dynamism of two different visual display terminal tasks on spontaneous eyeblink rate, blink amplitude, and tear film integrity. MATERIAL AND METHODS: A total of 25 healthy, young volunteers participated in the study. Blink rate and blink amplitude were recorded in silent primary gaze conditions and while subjects were playing two computer games of similar cognitive demands but different rate of visual information presentation. For each experimental condition, tear volume was evaluated by measuring meniscus height and with the red phenol thread test. Fluorescein and non-invasive break-up time tests, as well as the observation of interference patterns and the estimation of the dry area extension, were employed to assess tear stability. RESULTS: Statistically significant differences were revealed in blink rate (F = 595.85, p < 0.001) and blink amplitude (χ(2) = 34.00, p < 0.001), with blink rate during fast- and slow-paced game play decreasing to almost 1/3 and 1/2 of baseline levels, respectively, and with a larger percentage of incomplete blinks during dynamic tasks. Fluorescein and non-invasive break-up time tests and dry area extension were able to differentiate between experimental conditions in general (F = 408.42, p < 0.001; F = 163.49, p < 0.001; χ(2) = 20.74, p < 0.001), as well as between fast- and slow-paced games, thus suggesting that tear quality was more affected than tear volume. CONCLUSIONS: Blink rate, blink amplitude, and tear film stability were compromised during the most dynamic visual display terminal task, suggesting a negative influence of not only the cognitive aspects of the task, but also of the rate at which new visual information is presented. Frequent breaks and blinking awareness training are recommended for visual display terminal users requiring prolonged periods of visually demanding dynamic computer play or work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TFOS DEWS II pain and sensation report
Belmonte, C., Nichols, J. J., Cox, S. M., Brock, J. A., Begley, C. G., Bereiter, D. A., Dartt, D. A., Galor, A., Hamrah, P., Ivanusic, J. J., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.002 · Cited by 660
Jaiswal, S., Asper, L., Long, J., Lee, A., Harrison, K., & Golebiowski, B. (2019) · Clinical and Experimental Optometry · doi:10.1111/cxo.12851 · Cited by 302
Oral omega-3 fatty acids treatment in computer vision syndrome related dry eye
Bhargava, R., Kumar, P., Phogat, H., Kaur, A., & Kumar, M. (2015) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2015.01.007 · Cited by 103
Metadata
- Authors
- Cardona, G., García, C., Serés, C., Vilaseca, M., & Gispets, J.
- Venue
- Current Eye Research
- Publisher
- Informa UK Limited
- Published
- 2011-01-28
- Volume
- 36
- Issue
- 3
- Pages
- 190-197
- ISSN
- 0271-3683 (ISSN-L)
- 1460-2202
- OpenAlex
- W2079620582
- Cited by
- 238
- References
- 0
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blink Rate, Blink Amplitude, and Tear Film Integrity during Dynamic Visual Display Terminal Tasks. https://app.cochat.ai/papers/10.3109/02713683.2010.544442
- The paper
- Cardona, G., García, C., Serés, C., Vilaseca, M., & Gispets, J. (2011). Blink Rate, Blink Amplitude, and Tear Film Integrity during Dynamic Visual Display Terminal Tasks. Current Eye Research. https://doi.org/10.3109/02713683.2010.544442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.