CoChat

Swimming facilities and work-related asthma

Rosenman, Kenneth D., Millerick-May, Melissa, Reilly, Mary Jo, Flattery, Jennifer, Weinberg, Justine, Harrison, Robert, Lumia, Margaret, Stephens, Alicia C., Borjan, Marija · 2015 · Journal of Asthma
Cited by 36

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Exposure to chlorinated water in swimming facilities may aggravate preexisting asthma or cause new onset asthma. This may be a particular problem for individuals who work and therefore spend prolonged time at swimming facilities. Chloramines formed by the interaction of chlorine-based disinfection products with the nitrogen in water from human sweat, urine and skin cells are the suspected causal agents. METHODS: Cases were reviewed from the state surveillance systems in California (CA), Michigan (MI) and New Jersey (NJ) to identify individuals with confirmed work-related asthma (WRA) attributed to exposures in swimming pools, water parks or hydrotherapy spas. A standardized method was used to confirm cases. RESULTS: A total of 44 confirmed cases of WRA were identified; 17 from 1994 to 2011 in CA, 15 from 1991 to 2012 in MI and 12 from 1990 to 2011 in NJ. A majority (52.2%) of the cases were new onset; 31.8% secondary to an acute exposure incident and 20.4% to repeated exposure. These represented 0.3-1.6% of all confirmed cases of WRA received during these time periods. Maintenance workers (34.9%) and lifeguards (31.8%) were the most common occupations. CONCLUSIONS: Swimming pool workers were identified from three states where the pool environment was either a trigger of preexisting asthma or associated with new onset of WRA. Regulations to require air monitoring and improvements in ventilation are recommended to reduce exposure levels of chloramines, the presumed etiologic agents. Clinical assessment of patients with asthma should include consideration of the effect on respiratory symptoms from exposures in a swimming pool environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/02770903.2014.950428

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 17

  1. 10.1136/oem.2006.029850 · DOI
  2. Bernard A, 2011, Am J Respir Crit Care Med, 183, 570, 10.1164/rccm.201008-1306ED · DOI
  3. Clearie KL, 2010, Allergy, 65, 269, 10.1111/j.1398-9995.2009.02173.x · DOI
  4. Ngwenya N, 2013, Reviews of environmental contamination and toxicology, 111, 10.1007/978-1-4614-4717-7_4 · DOI
  5. Fornander L, 2013, Int Arch Occup Environ Health, 86, 571, 10.1007/s00420-012-0790-4 · DOI
  6. Jajosky RA, 1999, MMWR, 48, 1
  7. ASHRAE, 2003, 2003 ASHRAE Handbook – HVAC Applications
  8. Mohan A, 2010, Indian J Chest Dis Allied Sci, 52, 149, 10.5005/ijcdas-52-3-149 · DOI
  9. Henneberger PK, 1999, Int J Occup Environ Health, 5, 1, 10.1179/oeh.1999.5.1.1 · DOI
  10. Malo JL, 1991, Am Rev Respir Dis, 143, 528, 10.1164/ajrccm/143.3.528 · DOI · Paper page
  11. Chessor E, 2012, natatoriums. ASHRAE J, 54, 10
  12. Li J, 2009, Environ Sci Technol, 43, 60, 10.1021/es8016304 · DOI · Paper page
  13. 10.1016/j.watres.2011.02.024 · DOI · Paper page
  14. Cavestri RC, 2009, ASHRAE Tran, 115, 502
  15. ANSI/ASHRAE, 2013, ANSI/ASHRAE Standard 62.1-2013 ventilation for acceptable indoor air quality
  16. Baxter RC, 2012, ASHRAE J, 54, 24
  17. 10.1378/chest.08-0201 · DOI · Paper page

Cited by

See all 36

Metadata

Authors
Rosenman, K. D., Millerick-May, M., Reilly, M. J., Flattery, J., Weinberg, J., Harrison, R., Lumia, M., Stephens, A. C., & Borjan, M.
Venue
Journal of Asthma
Published
2014-08-26
Volume
52
Issue
1
Pages
52-58
ISSN
  • 0277-0903 (ISSN-L)
  • 1532-4303
OpenAlex
W2133881456
Cited by
36
References
14
FWCI
3.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.