Swimming facilities and work-related asthma
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Exposure to chlorinated water in swimming facilities may aggravate preexisting asthma or cause new onset asthma. This may be a particular problem for individuals who work and therefore spend prolonged time at swimming facilities. Chloramines formed by the interaction of chlorine-based disinfection products with the nitrogen in water from human sweat, urine and skin cells are the suspected causal agents. METHODS: Cases were reviewed from the state surveillance systems in California (CA), Michigan (MI) and New Jersey (NJ) to identify individuals with confirmed work-related asthma (WRA) attributed to exposures in swimming pools, water parks or hydrotherapy spas. A standardized method was used to confirm cases. RESULTS: A total of 44 confirmed cases of WRA were identified; 17 from 1994 to 2011 in CA, 15 from 1991 to 2012 in MI and 12 from 1990 to 2011 in NJ. A majority (52.2%) of the cases were new onset; 31.8% secondary to an acute exposure incident and 20.4% to repeated exposure. These represented 0.3-1.6% of all confirmed cases of WRA received during these time periods. Maintenance workers (34.9%) and lifeguards (31.8%) were the most common occupations. CONCLUSIONS: Swimming pool workers were identified from three states where the pool environment was either a trigger of preexisting asthma or associated with new onset of WRA. Regulations to require air monitoring and improvements in ventilation are recommended to reduce exposure levels of chloramines, the presumed etiologic agents. Clinical assessment of patients with asthma should include consideration of the effect on respiratory symptoms from exposures in a swimming pool environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Occupational asthma caused by chloramines in indoor swimming-pool air
Thickett, K. M., McCoach, J. S., Gerber, J. M., Sadhra, S., & Burge, P. S. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00232802 · Cited by 266
Exposure to trichloramine and respiratory symptoms in indoor swimming pool workers
Jacobs, J. H., Spaan, S., van Rooy, G. B. G. J., Meliefste, C., Zaat, V. A. C., Rooyackers, J. M., & Heederik, D. (2007) · European Respiratory Journal · doi:10.1183/09031936.00024706 · Cited by 223 · cited 1×
“These studies have been conducted in France [11], Italy [12], the Netherlands [13], Sweden [14], Switzerland [15] and the United States [16].”
BackgroundMassin, N., Bohadana, A. B., Wild, P., Héry, M., Toamain, J. P., & Hubert, G. (1998) · Occupational and Environmental Medicine · doi:10.1136/oem.55.4.258 · Cited by 181 · cited 2×
“These studies have been conducted in France [11], Italy [12], the Netherlands [13], Sweden [14], Switzerland [15] and the United States [16].”
BackgroundLi, J., & Blatchley, E. R. (2007) · Environmental Science & Technology · doi:10.1021/es070871+ · Cited by 177
Asthma and Swimming: A Meta-Analysis
Goodman, M., & Hays, S. (2008) · Journal of Asthma · doi:10.1080/02770900802165980 · Cited by 109
Indoor swimming pools, water chlorination and respiratory health
Nemery, B., Hoet, P. H. M., & Nowak, D. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00308602 · Cited by 107
Fantuzzi, G., Righi, E., Predieri, G., Giacobazzi, P., Mastroianni, K., & Aggazzotti, G. (2010) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph7041379 · Cited by 95
Definition and quantification of initial anthropogenic pollutant release in swimming pools
Keuten, M. G. A., Schets, F. M., Schijven, J. F., Verberk, J. Q. J. C., & van Dijk, J. C. (2012) · Water Research · doi:10.1016/j.watres.2012.04.012 · Cited by 92
(2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mer125 · Cited by 84
The fate of chlorine and chloramines in cooling towers Henry's law constants for flashoff
Holzwarth, G., Balmer, R. G., & Soni, L. (1984) · Water Research · doi:10.1016/0043-1354(84)90012-5 · Cited by 73
Swimming pool, respiratory health, and childhood asthma: Should we change our beliefs?
Uyan, Z. S., Carraro, S., Piacentini, G., & Baraldi, E. (2009) · Pediatric Pulmonology · doi:10.1002/ppul.20947 · Cited by 69
EXPOSURE TO CHLORAMINES IN THE ATMOSPHERE OF INDOOR SWIMMING POOLS
(1995) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/39.4.427 · Cited by 59
Ocular and Respiratory Symptoms Among Lifeguards at a Hotel Indoor Waterpark Resort
Dang, B., Chen, L., Mueller, C., Dunn, K. H., Almaguer, D., Roberts, J. L., & Otto, C. S. (2010) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0b013e3181cf00d5 · Cited by 29
Chlorine, Chlorination By-Products and Their Allergic and Respiratory Health Effects
Kohlhammer, Y., & Heinrich, J. (2007) · Current Respiratory Medicine Reviews · doi:10.2174/157339807779941839 · Cited by 13
Research works printed but not linked: 17
- 10.1136/oem.2006.029850 · DOI
- Bernard A, 2011, Am J Respir Crit Care Med, 183, 570, 10.1164/rccm.201008-1306ED · DOI
- Clearie KL, 2010, Allergy, 65, 269, 10.1111/j.1398-9995.2009.02173.x · DOI
- Ngwenya N, 2013, Reviews of environmental contamination and toxicology, 111, 10.1007/978-1-4614-4717-7_4 · DOI
- Fornander L, 2013, Int Arch Occup Environ Health, 86, 571, 10.1007/s00420-012-0790-4 · DOI
- Jajosky RA, 1999, MMWR, 48, 1
- ASHRAE, 2003, 2003 ASHRAE Handbook – HVAC Applications
- Mohan A, 2010, Indian J Chest Dis Allied Sci, 52, 149, 10.5005/ijcdas-52-3-149 · DOI
- Henneberger PK, 1999, Int J Occup Environ Health, 5, 1, 10.1179/oeh.1999.5.1.1 · DOI
- Malo JL, 1991, Am Rev Respir Dis, 143, 528, 10.1164/ajrccm/143.3.528 · DOI · Paper page
- Chessor E, 2012, natatoriums. ASHRAE J, 54, 10
- Li J, 2009, Environ Sci Technol, 43, 60, 10.1021/es8016304 · DOI · Paper page
- 10.1016/j.watres.2011.02.024 · DOI · Paper page
- Cavestri RC, 2009, ASHRAE Tran, 115, 502
- ANSI/ASHRAE, 2013, ANSI/ASHRAE Standard 62.1-2013 ventilation for acceptable indoor air quality
- Baxter RC, 2012, ASHRAE J, 54, 24
- 10.1378/chest.08-0201 · DOI · Paper page
Cited by
Disinfection by-products in drinking water: Occurrence, toxicity and abatement
Srivastav, A. L., Patel, N., & Chaudhary, V. K. (2020) · Environmental Pollution · doi:10.1016/j.envpol.2020.115474 · Cited by 342
Westerlund, J., Bryngelsson, I.-L., Löfstedt, H., Eriksson, K., Westberg, H., & Graff, P. (2019) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1536825 · Cited by 33
Wastensson, G., & Eriksson, K. (2020) · Critical Reviews in Toxicology · doi:10.1080/10408444.2020.1744514 · Cited by 30
Respiratory and Ocular Symptoms Among Employees at Swedish Indoor Swimming Pools
Löfstedt, H., Westerlund, J., Graff, P., Bryngelsson, I.-L., Mölleby, G., Olin, A.-C., Eriksson, K., & Westberg, H. (2016) · Journal of Occupational & Environmental Medicine · doi:10.1097/jom.0000000000000883 · Cited by 16
Metadata
- Authors
- Rosenman, K. D., Millerick-May, M., Reilly, M. J., Flattery, J., Weinberg, J., Harrison, R., Lumia, M., Stephens, A. C., & Borjan, M.
- Venue
- Journal of Asthma
- Publisher
- Informa UK Limited
- Published
- 2014-08-26
- Volume
- 52
- Issue
- 1
- Pages
- 52-58
- ISSN
- 0277-0903 (ISSN-L)
- 1532-4303
- OpenAlex
- W2133881456
- Cited by
- 36
- References
- 14
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.