Tinnitus Pitch: A Comparison of Three Measurement Methods
The DOI matches its Crossref record.
Abstract
The most prominent pitch of tinnitus was measured in 10 subjects with sensorineural tinnitus. The pitch was determined with three different psychophysical procedures in the ear ipsilateral to the tinnitus; an Adaptive Method (Bracketing), a Method of Limits (ascending and descending), and the Method of Adjustment. Each procedure involved equating the pitch of a pure tone to the most prominent tinnitus pitch, and was repeated seven times on each subject. Although there was no statistically significant difference for the means and standard deviations among the different methods for the group data, there were some large differences in a few individuals. Many of the subjects produced pitch matches that covered a range of 1 octave, whereas others showed better consistency. The Method of Limits took longer to perform and resulted in more octave confusions than the other two methods. The Adaptive Method was also repeated five times for each subject in the ear contralateral to the tinnitus. Two subjects produced a tinnitus pitch match that was over 1/2 octave lower in the contralateral ear. We recommend that tinnitus pitch be measured in the ipsilateral ear with either the Method of Adjustment or the Adaptive Method. Because some patients are unreliable in their pitch matching we suggest repeating the match seven to nine times.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
General Review of Tinnitus: Prevalence, Mechanisms, Effects, and Management
Henry, J. A., Dennis, K. C., & Schechter, M. A. (2005) · Journal of Speech, Language, and Hearing Research · doi:10.1044/1092-4388(2005/084 · Cited by 615
Norena, A., Micheyl, C., Chéry-Croze, S., & Collet, L. (2002) · Audiology and Neurotology · doi:10.1159/000066156 · Cited by 382
Psychoacoustic Measures of Tinnitus
Henry, J. A., & Meikle, M. B. (2000) · Journal of the American Academy of Audiology · doi:10.1055/s-0042-1748040 · Cited by 275
Aazh, H., Landgrebe, M., Danesh, A. A., & Moore, B. C. (2019) · Psychology Research and Behavior Management · doi:10.2147/prbm.s179138 · Cited by 75
“whistle, waterfall, grinding wheel, ringing, white noise, wind noise, bubbles, clicks, beeps, static noise and humming.(1,2) About 20% of patients are unable to describe what their tinnitus sounds like.”
BackgroundPhase-shift treatment for tinnitus of cochlear origin
Meeus, O., Heyndrickx, K., Lambrechts, P., De Ridder, D., & Van de Heyning, P. (2010) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-009-1145-y · Cited by 32
“tinnitus as closely as possible were already shown to be highly variable within the same subject [16, 17 ].”
Background
Metadata
- Authors
- Tyler, R. S., & Conrad-Armes, D.
- Venue
- British Journal of Audiology
- Publisher
- Informa UK Limited
- Published
- 1983-01
- Volume
- 17
- Issue
- 2
- Pages
- 101-107
- ISSN
- 0300-5364 (ISSN-L)
- OpenAlex
- W2082495008
- Cited by
- 94
- References
- 0
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tinnitus Pitch: A Comparison of Three Measurement Methods. https://app.cochat.ai/papers/10.3109/03005368309078916
- The paper
- Tyler, R. S., & Conrad-Armes, D. (1983). Tinnitus Pitch: A Comparison of Three Measurement Methods. British Journal of Audiology. https://doi.org/10.3109/03005368309078916
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.