The effect of probe to skin contact force on Cutometer MPA 580 measurements
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The variability is primarily caused by the perpendicularity and load exerted by the probe on the tissue (Serup et al., 2006; Bonaparte et al., 2013; Stroumza et al., 2015), which constitutes a significant source of manipulation bias (Stroumza et al., 2015).”
From Multimodal assessment of the skin biomechanical properties during wound healing and hyaluronic acid response (2026) · cites this paper as Bonaparte et al., 2013
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- Ahn S., 2007, Skin Research & Technology, 13, 280, 10.1111/j.1600-0846.2007.00224.x · DOI · Paper page
- Barbarino G.G., 2011, Skin Research & Technology, 17, 434, 10.1111/j.1600-0846.2011.00515.x · DOI
- Choi J.W., 2013, Skin Research & Technology, 19, e349, 10.1111/j.1600-0846.2012.00650.x · DOI
- Dobrev H, 2005, Skin Research & Technology, 11, 120, 10.1111/j.1600-0846.2005.00090.x · DOI · Paper page
- Fujimura T., 2007, Journal of Dermatological Science, 47, 233, 10.1016/j.jdermsci.2007.05.002 · DOI
- Nedelec B., 2008, Journal of Burn Care & Research, 29, 489, 10.1097/BCR.0b013e3181710869 · DOI
- Ohshima H., 2013, Skin Research & Technology, 19, e238, 10.1111/j.1600-0846.2012.00634.x · DOI · Paper page
- Ryu H.S., 2008, Skin Research & Technology, 14, 354, 10.1111/j.1600-0846.2008.00302.x · DOI · Paper page
- Sandford E., 2013, Skin Research & Technology, 19, e339, 10.1111/j.1600-0846.2012.00649.x · DOI
- Chin C.J., 2012, Journal of Otolaryngology - Head & Neck Surgery, 41, 320
- Naouri M., 2012, Journal of Cosmetic Dermatology, 11, 201, 10.1111/j.1473-2165.2012.00627.x · doi:10.1111/j.1473-2165.2012.00627.x
- Ono I, 2011, Journal of Cutaneous & Aesthetic Surgery, 4, 98, 10.4103/0974-2077.85022 · DOI
- Cua A.B., 1990, Archives of Dermatological Research, 282, 283, 10.1007/BF00375720 · DOI · Paper page
- Oxlund H., 1988, Journal of Biomechanics, 21, 213, 10.1016/0021-9290(88)90172-8 · DOI · Paper page
Cited by
Research on the Correlation Between Skin Elasticity Evaluation Parameters and Age
Chen, D., Yin, S., Lu, X., Fu, H., Gao, H., & Zhang, S. (2024) · Cosmetics · doi:10.3390/cosmetics11060205 · Cited by 22
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2026.107451 · Cited by 2
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · arXiv · doi:10.48550/arxiv.2611.20949 · Cited by 2
Metadata
- Authors
- Bonaparte, J. P., Ellis, D., & Chung, J.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2013-04
- Volume
- 37
- Issue
- 3
- Pages
- 208-212
- ISSN
- 0309-1902
- 1464-522X
- Cited by
- 44
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effect of probe to skin contact force on Cutometer MPA 580 measurements. https://app.cochat.ai/papers/10.3109/03091902.2013.779325
- The paper
- Bonaparte, J. P., Ellis, D., & Chung, J. (2013). The effect of probe to skin contact force on Cutometer MPA 580 measurements. Journal of Medical Engineering & Technology. https://doi.org/10.3109/03091902.2013.779325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.