Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Biomechanical analysis is a powerful tool in the evaluation of movement dysfunction in orthopaedic and neurologic populations. Three-dimensional (3D) motion capture systems are widely used, accurate systems, but are costly and not available in many clinical settings. The Microsoft Kinect™ has the potential to be used as an alternative low-cost motion analysis tool. The purpose of this study was to assess concurrent validity of the Kinect™ with Brekel Kinect software in comparison to Vicon Nexus during sagittal plane gait kinematics. Twenty healthy adults (nine male, 11 female) were tracked while walking and jogging at three velocities on a treadmill. Concurrent hip and knee peak flexion and extension and stride timing measurements were compared between Vicon and Kinect™. Although Kinect measurements were representative of normal gait, the Kinect™ generally under-estimated joint flexion and over-estimated extension. Kinect™ and Vicon hip angular displacement correlation was very low and error was large. Kinect™ knee measurements were somewhat better than hip, but were not consistent enough for clinical assessment. Correlation between Kinect™ and Vicon stride timing was high and error was fairly small. Variability in Kinect™ measurements was smallest at the slowest velocity. The Kinect™ has basic motion capture capabilities and with some minor adjustments will be an acceptable tool to measure stride timing, but sophisticated advances in software and hardware are necessary to improve Kinect™ sensitivity before it can be implemented for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Gait variability and fall risk in community-living older adults: A 1-year prospective study
Hausdorff, J. M., Rios, D. A., & Edelberg, H. K. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24893 · Cited by 2,313
The reliability of three-dimensional kinematic gait measurements: A systematic review
McGinley, J. L., Baker, R., Wolfe, R., & Morris, M. E. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.09.003 · Cited by 1,144
Data Analysis: A Model-Comparison Approach
Vining, G., Judd, C. M., & McClelland, G. H. (1992) · Technometrics · doi:10.2307/1269570 · Cited by 922
Validity of the Microsoft Kinect for assessment of postural control
Clark, R. A., Pua, Y.-H., Fortin, K., Ritchie, C., Webster, K. E., Denehy, L., & Bryant, A. L. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.03.033 · Cited by 687
Increased gait unsteadiness in community-dwelling elderly fallers
Hausdorff, J. M., Edelberg, H. K., Mitchell, S. L., Goldberger, A. L., & Wei, J. Y. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90034-4 · Cited by 593
Data Analysis: A Model-Comparison Approach.
Clark, V., Judd, C. M., & McClelland, G. H. (1990) · Journal of the American Statistical Association · doi:10.2307/2289821 · Cited by 580
Webster, K. E., Wittwer, J. E., & Feller, J. A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.10.005 · Cited by 556
Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace
Dutta, T. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.011 · Cited by 435
Real-time classification of dance gestures from skeleton animation
Raptis, M., Kirovski, D., & Hoppe, H. (2011) · Proceedings of the 2011 ACM SIGGRAPH/Eurographics Symposium on Computer Animation · doi:10.1145/2019406.2019426 · Cited by 302
Cited by
Evaluation of 3D Markerless Motion Capture Accuracy Using OpenPose With Multiple Video Cameras
Nakano, N., Sakura, T., Ueda, K., Omura, L., Kimura, A., Iino, Y., Fukashiro, S., & Yoshioka, S. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.00050 · Cited by 378
A Review on Technical and Clinical Impact of Microsoft Kinect on Physical Therapy and Rehabilitation
Mousavi Hondori, H., & Khademi, M. (2014) · Journal of Medical Engineering · doi:10.1155/2014/846514 · Cited by 360
Two-dimensional video-based analysis of human gait using pose estimation
Stenum, J., Rossi, C., & Roemmich, R. T. (2021) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1008935 · Cited by 321
Skublewska-Paszkowska, M., Milosz, M., Powroznik, P., & Lukasik, E. (2022) · Heritage Science · doi:10.1186/s40494-021-00633-x · Cited by 301
Accuracy and Reliability of the Kinect Version 2 for Clinical Measurement of Motor Function
Otte, K., Kayser, B., Mansow-Model, S., Verrel, J., Paul, F., Brandt, A. U., & Schmitz-Hübsch, T. (2016) · PLOS ONE · doi:10.1371/journal.pone.0166532 · Cited by 255
Accuracy of the Microsoft Kinect™ for measuring gait parameters during treadmill walking
Xu, X., McGorry, R. W., Chou, L.-S., Lin, J.-H., & Chang, C.-C. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.05.002 · Cited by 239
“Some previous studies [9–12] investigated the validity of the Kinect sensor for assessment of gait parameters.”
BackgroundClark, R. A., Mentiplay, B. F., Hough, E., & Pua, Y. H. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2018.11.029 · Cited by 209
Mentiplay, B. F., Perraton, L. G., Bower, K. J., Pua, Y.-H., McGaw, R., Heywood, S., & Clark, R. A. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.05.021 · Cited by 195
“From our experience with the Kinect V2, and the results of this and prior gait validation studies using the first iteration Kinect (Pfister et al., 2014), the variability between healthy participants in kinematic data is too small to be detectable given the joint angle error obtained.”
BackgroundMethodResultScataglini, S., Abts, E., Van Bocxlaer, C., Van den Bussche, M., Meletani, S., & Truijen, S. (2024) · Sensors · doi:10.3390/s24113686 · Cited by 159
“By addressing limitations associated with marker-based approaches, 3D markerless systems pave the way for more efficient, non-invasive, and ecologically valid motion capture solutions, advancing research and applications in fields ranging from biomechanics to clinical gait assessment.”
BackgroundA Novel Compensatory Motion Detection Method Using Multiple Signals and Machine Learning
Xu, P., Xia, D., Zheng, B., Huang, L., & Xie, L. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3190503 · Cited by 12
“Typical marker technology, such as the Vicon system, is the gold standard for human posture recognition [22]; however, it has a high cost, marker artifacts, complex operation, and site requirements [23].”
Background
Metadata
- Authors
- Pfister, A., West, A. M., Bronner, S., & Noah, J. A.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2014-05-30
- Volume
- 38
- Issue
- 5
- Pages
- 274-280
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2165744315
- Cited by
- 552
- References
- 25
- FWCI
- 16.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.