Toward the development of smart and low cost point-of-care biosensors based on screen printed electrodes
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Screen printing technology provides a cheap and easy means to fabricate disposable electrochemical devices in bulk quantities which are used for rapid, low-cost, on-site, real-time and recurrent industrial, pharmaceutical or environmental analyses. Recent developments in micro-fabrication and nano-characterization made it possible to screen print reproducible feature on materials including plastics, ceramics and metals. The processed features forms screen-printed disposable biochip (SPDB) upon the application of suitable bio-chemical recognition receptors following appropriate methods. Adequacy of biological and non-biological materials is the key to successful biochip development. We can further improve recognition ability of SPDBs by adopting new screen printed electrode (SPE) configurations. This review covers screen-printing theory with special emphasis on the technical impacts of SPE architectures, surface treatments, operational stability and signal sensitivity. The application of SPE in different areas has also been summarized. The article aims to highlight the state-of-the-art of SPDB at the laboratory scale to enable us in envisaging the deployment of emerging SPDB technology on the commercial scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immobilization strategies to develop enzymatic biosensors
Sassolas, A., Blum, L. J., & Leca-Bouvier, B. D. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.09.003 · Cited by 1,130 · cited 1×
“In contrast, covalent and affinity interactions provides more stable attachment and better orientation of RRs to the SPE (Sassolas et al., 2002).”
BackgroundElectrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors
Delaney, J. L., Hogan, C. F., Tian, J., & Shen, W. (2011) · Analytical Chemistry · doi:10.1021/ac102392t · Cited by 592 · cited 1×
“Delaney’s group has combined inkjet-printed paper-microfluidics with electrochemiluminescent (ECL) detection (Delaney et al., 2011) into a low cost, disposable sensor for being used with conventional photo detector or a camera phone (Figure 7).”
BackgroundA review of molecular recognition technologies for detection of biological threat agents
Iqbal, S. S., Mayo, M. W., Bruno, J. G., Bronk, B. V., Batt, C. A., & Chambers, J. P. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(00)00108-1 · Cited by 507
New directions in screen printed electroanalytical sensors: an overview of recent developments
Metters, J. P., Kadara, R. O., & Banks, C. E. (2011) · The Analyst · doi:10.1039/c0an00894j · Cited by 474 · cited 1×
“In SP – the ink or paste, which is a viscous fluid, is squeezed by a blade (3–10 Pa at a sheer rate of 230 s (1)) through a mesh-screen onto the substrate (Figure 2; Lanyon et al., 2006; Metters et al., 2011; Mistry et al., 2014).”
BackgroundInterdigitated array microelectrodes based impedance biosensors for detection of bacterial cells
Varshney, M., & Li, Y. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.001 · Cited by 360
Recent advances in biosensor techniques for environmental monitoring
Rogers, K. R. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.067 · Cited by 358
Tudorache, M., & Bala, C. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1293-0 · Cited by 316
Ahmed, M. U., Saaem, I., Wu, P. C., & Brown, A. S. (2014) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2013.778228 · Cited by 238
Self-citationApplication of Electrochemically Reduced Graphene Oxide on Screen-Printed Ion-Selective Electrode
Ping, J., Wang, Y., Ying, Y., & Wu, J. (2012) · Analytical Chemistry · doi:10.1021/ac203480z · Cited by 199 · cited 1×
“Figure 6 represents an all solid-state graphene-film modified electrode for Ca detection with Ca-ion-selective membrane which showed insensitivity to oxygen, water, light and redox-species (Ping et al., 2002).”
BackgroundElectrochemical Biosensors for Medical and Food Applications
Ahmed, M. U., Hossain, M. M., & Tamiya, E. (2008) · Electroanalysis · doi:10.1002/elan.200704121 · Cited by 195
Self-citationPaper-based electroanalytical devices for accessible diagnostic testing
Maxwell, E. J., Mazzeo, A. D., & Whitesides, G. M. (2013) · MRS Bulletin · doi:10.1557/mrs.2013.56 · Cited by 189
Glucose biosensor based on multi-wall carbon nanotubes and screen printed carbon electrodes
Guan, W., Yu, L., Chen, Y., et al. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.030 · Cited by 132 · cited 1×
“Multi-wall carbon nanotubes were used in enzyme based biosensors for higher sensitivity and faster analysis (Guan et al., 2005).”
MethodSensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
de Mattos, I. L., Gorton, L. G. O., & Ruzgas, T. A. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00185-9 · Cited by 129
Wearable electrochemical sensors for in situ analysis in marine environments
Malzahn, K., Windmiller, J. R., Valdés-Ramírez, G., Schöning, M. J., & Wang, J. (2011) · The Analyst · doi:10.1039/c1an15193b · Cited by 127 · cited 1×
“printed electrochemical sensor on neoprene substrate has been reported that detect the presence of trace heavy metals contaminants and nitroaromatic explosives such as 2,4,6trinitrotoluene (TNT) in seawater (Malzahn et al., 2011).”
BackgroundMicrofluidic electrochemical assay for rapid detection and quantification of Escherichia coli
Safavieh, M., Ahmed, M. U., Tolba, M., & Zourob, M. M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.032 · Cited by 127
Self-citationA review on amperometric-type immunosensors based on screen-printed electrodes
Mistry, K. K., Layek, K., Mahapatra, A., Roychaudhuri, C., & Saha, H. (2014) · The Analyst · doi:10.1039/c3an02050a · Cited by 127
Novel electrochemical immunosensors for seafood toxin analysis
Kreuzer, M. P., Pravda, M., O’Sullivan, C. K., & Guilbault, G. G. (2002) · Toxicon · doi:10.1016/s0041-0101(02)00132-0 · Cited by 122 · cited 4×
“However, the toxicity of Hg has led to the development of a bismuth-based novel sensor for single step Pb(II) with 5–50 ppb LOD (Fang et al., 2011).”
InfluentialA simple cassette as point-of-care diagnostic device for naked-eye colorimetric bacteria detection
Safavieh, M., Ahmed, M. U., Sokullu, E., Ng, A., Braescu, L., & Zourob, M. M. (2013) · The Analyst · doi:10.1039/c3an01859h · Cited by 122
Self-citationAhmed, M. U., Hasan, Q., Hossain, M. M., Saito, M., & Tamiya, E. (2009) · Food Control · doi:10.1016/j.foodcont.2009.09.001 · Cited by 120 · cited 2×
“RuHex based electrostatic redox probe: Real-time detection of LAMP amplicons in polypropylene tube fitted SPE (A); before amplification diffusion of free RuHex towards cathode produced high current (B,a), after amplification electrostatic bonding of RuHex to LAMP amplicon lowerd the current as observed by SWV (B,b); E…”
MethodSelf-citationReal-time electrochemical detection of pathogen DNA using electrostatic interaction of a redox probe
Ahmed, M. U., Nahar, S., Safavieh, M., & Zourob, M. M. (2012) · The Analyst · doi:10.1039/c2an36153a · Cited by 118 · cited 1×
“This approach has been successfully used for real-time monitoring of loop mediated isothermal amplification (LAMP) amplicons of target genes from Escherichia coli and Staphylococcus aureus by square wave voltametry (SWV; Ahmed et al., 2013) by avoiding cross contamination through concurrent amplification and realtime…”
MethodSelf-citationMedina‐Sánchez, M., Miserere, S., Morales‐Narváez, E., & Merkoçi, A. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.069 · Cited by 117 · cited 1×
“A microfluidic chip was used for sample preconcentration in electrochemical detection of apolipoprotein E (ApoE) for diagnosis of Alzheimer’s on SPE where cadmium-selenide/zinc-sulfide (CdSe–ZnS) quantum dots (QDs) have been used as labeling carriers (Medina-Sanchez et al., 2014).”
MethodScreen Printing of Nucleic Acid Detecting Carbon Electrodes
Dequaire, M., & Heller, A. (2002) · Analytical Chemistry · doi:10.1021/ac025541g · Cited by 112
Du, D., Wang, J., Lu, D., Dohnalkova, A. C., & Lin, Y. (2011) · Analytical Chemistry · doi:10.1021/ac2009977 · Cited by 112 · cited 1×
“Enzyme-antibody hybrid has promising biomedical POC diagnostic applications, for instance, phosphorylated proteins in human plasma by a multiplexed electrochemical immunoassay based on integrated enzyme amplification and electric field driven strategy (Du et al., 2011).”
MethodCrouch, E., Cowell, D. C., Hoskins, S., Pittson, R. W., & Hart, J. P. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.003 · Cited by 112 · cited 1×
“Using a water-based carbon ink, Crouch et al. (2005) has constructed a disposable amperometric glucose sensor which addressed the risk of enzyme denaturalisations at high temperatures.”
BackgroundMonitoring Dopamine Release from Single Living Vesicles with Nanoelectrodes
Wen, W., Huang, W., Wang, W., Wang, Z., Cheng, J.-K., Xu, T., Zhang, R., Chen, Y., & Liu, J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja050385r · Cited by 111
Silber, A., Hampp, N., & Schuhmann, W. W. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)88408-9 · Cited by 108 · cited 1×
“(1996) further simplified the entrapment protocol through one-step electropolymerization of a mixture of glucose dehydrogenase (GDH) in methylene blue (MB) monomers on a thick-film gold electrode (Silber et al., 1996).”
BackgroundRius-Ruiz, F. X., Crespo, G. A., Bejarano-Nosas, D., Blondeau, P., Riu, J., & Rius, F. X. (2011) · Analytical Chemistry · doi:10.1021/ac202070r · Cited by 108 · cited 1×
“SWCNT-Octadecylamine (ODA) was used as ion to electron transducer layer (Rius-Ruiz et al., 2011).”
MethodSong, W., Li, H., Liang, H., Qiang, W., & Xu, D. (2014) · Analytical Chemistry · doi:10.1021/ac500011k · Cited by 108 · cited 1×
“Microelectrode arrays (MEA) are under investigation as they allow significant increase in temporal resolution, current densities and faradic to capacitive current ratio (Abdellaoui et al., 2013; Song et al., 2014).”
BackgroundIbarra-Escutia, P., Juárez‐Gómez, J., Calas‐Blanchard, C., Marty, J., & Ramírez-Silva, M. T. (2010) · Talanta · doi:10.1016/j.talanta.2010.03.017 · Cited by 100 · cited 1×
“Tidineprepolymer (PAP) and polyvinyl alcohol photopolymer entrapped laccase on SPE surfaces to filter impurities in the analysis of phenolic compounds (Ibarra-Escutia et al., 2010).”
BackgroundAhmed, M. U., Saito, M., Hossain, M. M., Rao, S. R., Furui, S., Hino, A., Takamura, Y., Takagi, M., & Tamiya, E. (2009) · The Analyst · doi:10.1039/b812569d · Cited by 95 · cited 2×
“Tamiya and coworkers has developed the DNA stick (Figure 10) – DNA amplification system – to be integrated with SPDB (Ahmed et al., 2009).”
Self-citationIdegami, K., Chikae, M., Kerman, K., Nagatani, N., Yuhi, T., Endo, T., & Tamiya, E. (2007) · Electroanalysis · doi:10.1002/elan.200704011 · Cited by 92
Self-citationHigh-throughput real-time electrochemical monitoring of LAMP for pathogenic bacteria detection
Safavieh, M., Ahmed, M. U., Ng, A., & Zourob, M. M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.002 · Cited by 90 · cited 1×
“[Reproduced with permission from Safavieh et al. (2012)].”
Self-citationDisposable immunosensor for the determination of domoic acid in shellfish
Micheli, L., Radoi, A., Guarrina, R., Massaud, R., Bala, C., Moscone, D., & Palleschi, G. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.031 · Cited by 83 · cited 4×
“However, the toxicity of Hg has led to the development of a bismuth-based novel sensor for single step Pb(II) with 5–50 ppb LOD (Fang et al., 2011).”
InfluentialNovel planar glucose biosensors for continuous monitoring use
Ricci, F., Moscone, D., Tuta, C. S., Palleschi, G., Amine, A., Poscia, A., Valgimigli, F., & Messeri, D. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.09.010 · Cited by 75 · cited 1×
“In order to reduce the cost of electrode surface functionalization in disposable electrochemical chips, we need stable enzymatic reactions which can be achieved through cross-linking (Gonzalo-Ruiz et al., 2007; Ricci et al., 2005) or probe crystallization methods (de Mattos et al.”
MethodAhmed, M. U., Idegami, K., Chikae, M., Kerman, K., Chaumpluk, P., Yamamura, S., & Tamiya, E. (2007) · The Analyst · doi:10.1039/b615242b · Cited by 75 · cited 1×
“Single nucleotide polymorphisms (SNPs) sensors have also been reported (Ahmed et al., 2007).”
BackgroundSelf-citationReal-time electrochemical monitoring of isothermal helicase-dependent amplification of nucleic acids
Kivlehan, F., Mavré, F., Talini, L., Limoges, B., & Marchal, D. (2011) · The Analyst · doi:10.1039/c1an15289k · Cited by 72 · cited 1×
“been reported by Kivlehan et al. (2011) for real-time detection of isothermal nucleic acids amplicons.”
BackgroundAntibiotic Susceptibility Testing at a Screen-Printed Carbon Electrode Array
Mann, T. S., & Mikkelsen, S. R. (2008) · Analytical Chemistry · doi:10.1021/ac701829c · Cited by 67
Disposable Biosensor Test for Organophosphate and Carbamate Insecticides in Milk
Zhang, Y., Muench, S. B., Schulze, H., Perz, R. C., Yang, B., Schmid, R. D., & Bachmann, T. T. (2005) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf050302q · Cited by 56 · cited 1×
“, 2004), insecticides (Zhang et al., 2005) and other targets such as glycerol (Radoi et al.”
BackgroundHeld, M., Schuhmann, W. W., Jahreis, K., & Schmidt, H.-L. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00103-3 · Cited by 52 · cited 3×
“based sensor has been found useful for mono and disaccharide detection in an FIA (Held et al., 2002).”
MethodSchüler, T., Asmus, T., Fritzsche, W., & Möller, R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.10.028 · Cited by 49 · cited 1×
“, 2006), viruses (Schüler et al., 2009), drugs (Luangaram et al.”
Viết, N. X., Chikae, M., Ukita, Y., Maehashi, K., Matsumoto, K., Tamiya, E., Viet, P. H., & Takamura, Y. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.11.017 · Cited by 48
Self-citationCorrigan, D. K., Schulze, H., Henihan, G., Hardie, A., Ciani, I., Giraud, G., Terry, J. G., Walton, A. J., Pethig, R., Ghazal, P., et al. (2013) · The Analyst · doi:10.1039/c3an01319g · Cited by 45
Prussian blue modified amperometric FIA biosensor: one-step immunoassay for α-fetoprotein
Guan, J., Miao, Y.-Q., & Chen, J.-R. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.006 · Cited by 44
A 96-Well Electrochemical Method for the Screening of Enzymatic Activities
Abdellaoui, S., Noiriel, A., Henkens, R. W., Bonaventura, C., Blum, L. J., & Doumèche, B. (2013) · Analytical Chemistry · doi:10.1021/ac303777r · Cited by 41 · cited 1×
“Microelectrode arrays (MEA) are under investigation as they allow significant increase in temporal resolution, current densities and faradic to capacitive current ratio (Abdellaoui et al., 2013; Song et al., 2014).”
BackgroundChallier, L., Miranda‐Castro, R., Marchal, D., Noël, V., Mavré, F., & Limoges, B. (2013) · Journal of the American Chemical Society · doi:10.1021/ja405415q · Cited by 35 · cited 1×
“modified chip configurations for sensitive and stable SPDBs (Challier et al., 2013,). Disc, ring and band are the most fundamental configurations for SPDBs (Evtugyn et al., 2003; Rogers, 2006). Konash et al.’s (2009) studied that carbon-inkbased micro-tubular band-electrode in fixed-volume enzymereaction well can be s…”
BackgroundDisposable Sensor for Measurement of Vitamin B2 in Nutritional Premix, Cereal, and Milk Powder
Kadara, R. O., Haggett, B. G. D., & Birch, B. J. (2006) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0603376 · Cited by 29 · cited 1×
“2006), vitamin B1 (Kadara et al., 2006) and lean meat agents which are major food-safety concern (Li et al.”
BackgroundAziz, A. A., & Wong, F. L. (2011) · Engineering in Life Sciences · doi:10.1002/elsc.201000039 · Cited by 12
Enzyme Biosensors Based on Mediator-Modified Carbon Paste Electrode
Pandey, P. C. (2003) · Humana Press eBooks · doi:10.1385/0-89603-410-0:81 · Cited by 6
A DISPOSABLE BIOSENSOR ARRAY FOR MONITORING HUMAN METABOLIC PARAMETERS AND ITS APPLICATIONS
Gao, C. (2005) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Cited by
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Advanced Materials for Printed Wearable Electrochemical Devices: A Review
Kim, J., Kumar, R., Bandodkar, A. J., & Wang, J. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600260 · Cited by 452
Point of care testing: The impact of nanotechnology
Syedmoradi, L., Daneshpour, M., Alvandipour, M., Gomez, F. A., Hajghassem, H., & Omidfar, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.084 · Cited by 367
Review—An Overview on Recent Progress in Screen-Printed Electroanalytical (Bio)Sensors
Singh, S., Wang, J., & Cinti, S. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac70e2 · Cited by 300
Zhang, Y., Jiang, X., Zhang, J., Zhang, H., & Li, Y. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.043 · Cited by 289
Metadata
- Authors
- Ahmed, M. U., Hossain, M. M., Safavieh, M., Wong, Y. L., Rahman, I. A., Zourob, M., & Tamiya, E.
- Venue
- Critical Reviews in Biotechnology
- Publisher
- Informa UK Limited
- Published
- 2015-01-12
- Volume
- 36
- Issue
- 3
- Pages
- 1-11
- ISSN
- 0738-8551 (ISSN-L)
- 1549-7801
- OpenAlex
- W2052267438
- Cited by
- 161
- References
- 49
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.