Dielectrophoresis: Using Inhomogeneous AC Electrical Fields to Separate and Manipulate Cells
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Dielectrophoresis is the motion of particles caused by electrical polarization effects in inhomogeneous (nonuniform) electric fields. Unlike electrophoresis, the particles do not require a net electrical charge for motion to occur and AC rather than DC fields are employed to exploit the dielectric properties of the particles. Factors controlling the effective dielectric properties of cells and microorganisms include electrical double layers associated with surface charges, the conductivity and permittivity of their membranes and any cell walls, and their morphologies and structural architectures. In recent years, several laboratories have developed separation and manipulation techniques for cells and microorganisms based on dielectrophoresis, using both static and traveling AC fields. In this article, the basic physical factors influencing the dielectrophoretic behavior of particles are outlined, and ways in which these can be employed to achieve selective separation of cells and microorganisms are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goycoolea, A. (1997) · Cited by 3,615
Jones, T. B. (1995) · doi:10.1017/cbo9780511574498 · Cited by 2,786
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Erklärung der dielektrischen Nachwirkungsvorgänge auf Grund Maxwellscher Vorstellungen
Wagner, K. W. (1914) · Archiv für Elektrotechnik · doi:10.1007/bf01657322 · Cited by 1,137
The colloidal domain: where physics, chemistry, biology, and technology meet
(1995) · Choice Reviews Online · doi:10.5860/choice.32-3315 · Cited by 1,130
The Motion and Precipitation of Suspensoids in Divergent Electric Fields
Pohl, H. A. (1951) · Journal of Applied Physics · doi:10.1063/1.1700065 · Cited by 1,097
Dielectric and electronic properties of biological materials
Pethig, R. (1979) · Cited by 707
Self-citationRed Blood Cell Damage by Shear Stress
Leverett, L. B., Hellums, J. D., Alfrey, C. P., & Lynch, E. C. (1972) · Biophysical Journal · doi:10.1016/s0006-3495(72)86085-5 · Cited by 682
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Self-citationDielectric and Electronic Properties of Biological Materials
Willis, M. (1980) · Biochemical Education · doi:10.1016/0307-4412(80)90102-8 · Cited by 462
Pethig, R., Huang, Y., Wang, X.-B., & Burt, J. P. H. (1992) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/25/5/022 · Cited by 312
Self-citationDielectrophoretic characterization and separation of micro-organisms
Markx, G. H., Huang, Y., Zhou, X. F., & Pethig, R. (1994) · Microbiology · doi:10.1099/00221287-140-3-585 · Cited by 237
Self-citationSelective dielectrophoretic confinement of bioparticles in potential energy wells
Wang, X. B., Huang, Y., Burt, J. P. H., Markx, G. H., & Pethig, R. (1993) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/26/8/019 · Cited by 223
Self-citationShear sensitivity of insect cells in suspension
Tramper, J., Williams, J. B., Joustra, D., & Vlak, J. M. (1986) · Enzyme and Microbial Technology · doi:10.1016/0141-0229(86)90007-4 · Cited by 203
Dielectrophoretic separation of bacteria using a conductivity gradient
Markx, G. H., Dyda, P. A., & Pethig, R. (1996) · Journal of Biotechnology · doi:10.1016/0168-1656(96)01617-3 · Cited by 191
Self-citationNovel method of cell fusion in field constriction area in fluid integration circuit
Masuda, S., Washizu, M., & Nanba, T. (1989) · IEEE Transactions on Industry Applications · doi:10.1109/28.31255 · Cited by 190
Electromanipulation and separation of cells using travelling electric fields
Talary, M. S., Burt, J. P. H., Tame, J. A., et al. (1996) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/29/8/021 · Cited by 152
Multipolar dielectrophoretic force calculation
Washizu, M., & Jones, T. B. (1994) · Journal of Electrostatics · doi:10.1016/0304-3886(94)90053-1 · Cited by 141
Separation of Small Particles Suspended in Liquid by Nonuniform Traveling Field
Masuda, S., Washizu, M., & Iwadare, M. (1987) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1987.4504934 · Cited by 124
Wang, X. B., Huang, Y., Hölzel, R., Burt, J. P. H., & Pethig, R. (1993) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/26/2/021 · Cited by 119
Self-citationRadio-Frequency Microtools for Particle and Live Cell Manipulation
Fuhr, G., M�ller, T. H., Schnelle, T., Hagedorn, R., Voigt, A., Fiedler, S., Arnold, W. M., Zimmermann, U., Wagner, B., & Heuberger, A. (1994) · Die Naturwissenschaften · doi:10.1007/bf01139998 · Cited by 115
Movement of blood cells in liquid by nonuniform traveling field
Masuda, S., Washizu, M., & Kawabata, I. (1988) · IEEE Transactions on Industry Applications · doi:10.1109/28.2859 · Cited by 113
Shear Stress Effects on Human T Cell Function
Chittur, K. K., McIntire, L. V., & Rich, R. R. (1988) · Biotechnology Progress · doi:10.1002/btpr.5420040207 · Cited by 58
Wilson, R. J. A., Breckenridge, L. J., Blackshaw, S. E., Connolly, P., Dow, J. A. T., Curtis, A. S. G., & Wilkinson, C. D. W. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90150-3 · Cited by 43
Model-Independent Aspects of Field–Flow Fractionation Theory
Buffham, B. A. (1996) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1996.0406 · Cited by 7
Cited by
Ac electrokinetics: a review of forces in microelectrode structures
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1998) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/31/18/021 · Cited by 1,233
Diffuse-charge dynamics in electrochemical systems
Bazant, M. Z., Thornton, K., & Ajdari, A. (2004) · Physical Review E · doi:10.1103/physreve.70.021506 · Cited by 1,053
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Dielectrophoretic Assembly of Electrically Functional Microwires from Nanoparticle Suspensions
Hermanson, K. D., Lumsdon, S. O., Williams, J. P., Kaler, E. W., & Velev, O. D. (2001) · Science · doi:10.1126/science.1063821 · Cited by 561
Metadata
- Authors
- Pethig, R.
- Venue
- Critical Reviews in Biotechnology
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 16
- Issue
- 4
- Pages
- 331-348
- ISSN
- 0738-8551 (ISSN-L)
- 1549-7801
- OpenAlex
- W2163529431
- Cited by
- 286
- References
- 25
- FWCI
- 10.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.