Increased bronchial nitric oxide production in patients with asthma measured with a novel method of different exhalation flow rates
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The concentration of nitric oxide (NO) in exhaled air is increased in patients with asthma, suggesting that measuring fractional exhaled NO concentration (FE(NO)) may be used to monitor asthmatic airway inflammation. However, increased FE(NO) is not specific for asthma, as other inflammatory lung diseases may also increase FE(NO). To augment the specificity of FE(NO) measurement, we tested a novel theoretical modelling of pulmonary NO dynamics that allows the approximation of alveolar NO concentration and bronchial NO flux separately by measuring FE(NO) at several exhalation flow rates. We measured FE(NO) at four exhalation flow rates in 10 steroid-naive asthmatics, 5 patients with extrinsic allergic alveolitis, and in 10 healthy controls. Both the asthmatics and the patients with alveolitis had significantly higher FE(NO) than the healthy controls. The increased NO concentration originated from the bronchial level in the asthmatics and from the alveolar level in the patients with alveolitis. In the second part of the study we assessed the repeatability of FE(NO) test, within-day and day-to-day (during two weeks) variation in FE(NO), and the effects of mouth pressure and cigarette smoking on FE(NO) in healthy volunteers. Repeatability of 10 subsequent measurements was high (coefficient of variation (CV) 4.6% +/- 0.4%), and no diurnal variation was found. The day-to-day variation during a 2-week period gave a CV of 10.6% +/- 1.0%. The magnitude of mouth pressure (5-20 cmH2O in adults, 5-40 cmH2O in children) during measurement had no effect on FE(NO). Smoking a cigarette caused a small and transient but statistically significant increase in FE(NO) at 1 and 5 min after smoking. In conclusion, FE(NO) measurement is highly repeatable with low day-to-day variation among healthy subjects. Our results also suggest that the present novel method of measuring FE(NO) at several exhalation flow rates can be used to approximate alveolar and bronchial contributions to FE(NO) separately and thus increase the clinical value of this test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232
Endogenous nitric oxide is present in the exhaled air of rabbits, guinea pigs and humans
Gustafsson, L. E., Leone, A. M., Persson, M. G., Wiklund, N. P., & Moncada, S. (1991) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(91)91268-h · Cited by 964
High nitric oxide production in human paranasal sinuses
Lundberg, J. O. N., Farkas-Szallasi, T., Weitzberg, E., Rinder, J., Lidholm, J., Änggåard, A., Hökfelt, T., Lundberg, J. M., & Alving, K. (1995) · Nature Medicine · doi:10.1038/nm0495-370 · Cited by 628
Single-breath nitric oxide measurements in asthmatic patients and smokers
Persson, M. G., Gustafsson, L. E., Zetterström, O., Agrenius, V., & Ihre, E. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90935-0 · Cited by 483
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Biomarkers of some pulmonary diseases in exhaled breath
Kharitonov, S. A., & Barnes, P. J. (2002) · Biomarkers · doi:10.1080/13547500110104233 · Cited by 290
Exhaled nitric oxide from lung periphery is increased in COPD
Brindicci, C., Ito, K., Resta, O., Pride, N. B., Barnes, P. J., & Kharitonov, S. A. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00125304 · Cited by 206
“There was no difference in Calv,NO between current smokers and ex-smokers, although Jaw,NO was reduced, thus, confirming previous studies [8, 13 ] which show a reduced eNO using the )+ & ,-. )+ & ,-.”
BackgroundMethodResultInfluentialExtended Exhaled NO Measurement Differentiates between Alveolar and Bronchial Inflammation
LEHTIMÄKI, L., KANKAANRANTA, H., SAARELAINEN, S., HAHTOLA, P., JÄRVENPÄÄ, R., KOIVULA, T., TURJANMAA, V., & MOILANEN, E. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2010171 · Cited by 186
Self-citation
Metadata
- Authors
- Lehtimäki, L., Turjanmaa, V., Kankaanranta, H., Saarelainen, S., Hahtola, P., & Moilanen, E.
- Venue
- Annals of Medicine
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 32
- Issue
- 6
- Pages
- 417-423
- ISSN
- 0785-3890 (ISSN-L)
- 1365-2060
- OpenAlex
- W2043506162
- Cited by
- 64
- References
- 4
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.