The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Extended Exhaled NO Measurement Differentiates between Alveolar and Bronchial Inflammation
Abstract
Lower respiratory tract inflammation can be detected by measuring exhaled nitric oxide (NO) concentration at a single exhalation flow rate, but this does not differentiate between alveolar and bronchial NO production. We assessed alveolar NO concentration and bronchial NO flux with an extended method of measuring exhaled NO at several exhalation flow rates in 40 patients with asthma, 17 patients with alveolitis, and 57 healthy control subjects. Bronchial NO flux was higher in asthma (2.5 +/- 0.3 nl/s, p < 0.001) than in alveolitis (0.7 +/- 0.1 nl/s) and healthy control subjects (0.7 +/- 0.1 nl/s). Alveolar NO concentration was higher in alveolitis (4.1 +/- 0.3 ppb, p < 0.001) than in asthma (1.1 +/- 0.2 ppb) and healthy control subjects (1.1 +/- 0.1 ppb). In asthma, bronchial NO flux correlated with serum level of eosinophil protein X (EPX) (r = 0.60, p < 0.001) and bronchial hyperresponsiveness (r = 0.55, p < 0.001). In alveolitis, alveolar NO concentration correlated inversely with pulmonary diffusing capacity (r = -0.55, p = 0.022) and pulmonary restriction. Glucocorticoid treatment or allergen avoidance normalized bronchial NO flux in asthma and decreased alveolar NO concentration toward normal in alveolitis. In conclusion, extended exhaled NO measurement can be used to separately assess alveolar and bronchial inflammation and to assess disease activity/severity in asthma and alveolitis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668
Cited by
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Nitric oxide in health and disease of the respiratory system
Ricciardolo, F. L. M., Sterk, P. J., Gaston, B., & Folkerts, G. (2004) · Physiological Reviews · doi:10.1152/physrev.00034.2003 · Cited by 903
Techniques of assessing small airways dysfunction
McNulty, W., & Usmani, O. S. (2014) · European Clinical Respiratory Journal · doi:10.3402/ecrj.v1.25898 · Cited by 275
Exhaled nitric oxide from lung periphery is increased in COPD
Brindicci, C., Ito, K., Resta, O., Pride, N. B., Barnes, P. J., & Kharitonov, S. A. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00125304 · Cited by 206
Metadata
- Authors
- LEHTIMÄKI, L., KANKAANRANTA, H., SAARELAINEN, S., HAHTOLA, P., JÄRVENPÄÄ, R., KOIVULA, T., TURJANMAA, V., & MOILANEN, E.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-06-01
- Volume
- 163
- Issue
- 7
- Pages
- 1557-1561
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2032393468
- Cited by
- 186
- References
- 1
- FWCI
- 5.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extended Exhaled NO Measurement Differentiates between Alveolar and Bronchial Inflammation. https://app.cochat.ai/papers/10.1164/ajrccm.163.7.2010171
- The paper
- LEHTIMÄKI, L., KANKAANRANTA, H., SAARELAINEN, S., HAHTOLA, P., JÄRVENPÄÄ, R., KOIVULA, T., TURJANMAA, V., & MOILANEN, E. (2001). Extended Exhaled NO Measurement Differentiates between Alveolar and Bronchial Inflammation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.163.7.2010171
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.