Detection of autoantibodies using chemiluminescence technologies
Open accessThe DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
CONTEXT: Although autoantibody detection methods such as indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assays (ELISAs) have been available for many years and are still in use the innovation of fast, fully automated instruments using chemiluminescence technology in recent years has led to rapid adoption in autoimmune disease diagnostics. In 2009, BIO-FLASH, a fully automated, random access chemiluminescent analyzer, was introduced, proceeded by the development of the QUANTA Flash chemiluminescent immunoassays (CIA) for autoimmune diagnostics. OBJECTIVE: To summarize the evolution of CIAs for the detection of autoantibodies and to review their performance characteristics. METHODS: Pubmed was screened for publications evaluating novel QUANTA Flash assays and how they compare to traditional methods for the detection of autoantibodies. In addition, comparative studies presented at scientific meetings were summarized. RESULTS: Several studies were identified that compared the novel CIAs with conventional methods for autoantibody detection. The agreements ranged from moderate to excellent depending on the assay. The studies show how the CIA technology has enhanced the analytical and clinical performance characteristics of many autoantibody assays supporting both diagnosis and follow-up testing. CONCLUSION: CIA has started to improve the diagnostic testing of autoantibodies as an aid in the diagnosis of a broad range of autoimmune diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Due to the stringent washing procedure, made possible through the wash steps with magnetic fixation of the beads, this assay is highly specific for SLE, as most low-avidity antibodies are removed.”
From Comparison of Five Assays for the Detection of Anti-dsDNA Antibodies and Their Correlation with Complement Consumption (2025) · cites this paper as [10]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · PubMed · Cited by 7,011
Enzyme-linked immunosorbent assay (ELISA) quantitative assay of immunoglobulin G
Engvall, E., & Perlmann, P. (1971) · Immunochemistry · doi:10.1016/0019-2791(71)90454-x · Cited by 3,777
Husby, S., Koletzko, S., Korponay‐Szabó, I. R., Mearin, M. L., Phillips, A., Shamir, R., Troncone, R., Giersiepen, K., Branski, D., Catassi, C., et al. (2012) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0b013e31821a23d0 · Cited by 2,683
Development of Autoantibodies before the Clinical Onset of Systemic Lupus Erythematosus
Arbuckle, M. R., McClain, M. T., Rubertone, M. V., Scofield, R. H., Dennis, G. J., James, J. A., & Harley, J. B. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021933 · Cited by 2,578
Renal-Limited “Lupus-Like” Nephritis: How Much of a Lupus
Maziad, A. S. A., Torrealba, J., Seikaly, M. G., Hassler, J. R., & Hendricks, A. R. (2017) · Case Reports in Nephrology and Dialysis · doi:10.1159/000475493 · Cited by 1,299
Singer, J. M., & Plotz, C. M. (1956) · The American Journal of Medicine · doi:10.1016/0002-9343(56)90103-6 · Cited by 1,165 · cited 2×
“com/ipi ISSN: 0892-3973 (print), 1532-2513 (electronic) Immunopharmacol Immunotoxicol, 2016; 38(1): 14–20”
Assay of Plasma Insulin in Human Subjects by Immunological Methods
YALOW, R. S., & BERSON, S. A. (1959) · Nature · doi:10.1038/1841648b0 · Cited by 1,098
Immunoassay using antibody—enzyme conjugates
van Weemen, B. K., Schuurs, A. H. W. M., Oostermeijer, M. W., & Raymakers, H. H. T. (1974) · FEBS Letters · doi:10.1016/0014-5793(74)81003-3 · Cited by 869
Immunoassay using antigen—enzyme conjugates
Van Weemen, B. K., & Schuurs, A. H. W. M. (1971) · FEBS Letters · doi:10.1016/0014-5793(71)80319-8 · Cited by 860
Chemiluminescence as diagnostic tool. A review
Dodeigne, C. (2000) · Talanta · doi:10.1016/s0039-9140(99)00294-5 · Cited by 563
Research works printed but not linked: 1
- Infantino M, Meacci F, Bentow C, et al. Clinical comparison of QUANTA Flash dsDNA chemiluminescent immunoassay with four current assays for the detection of anti-dsDNA autoantibodies. J Immunol Res 2015;2015:902821 PMC4352420 25759849
Cited by
Emerging technologies in autoantibody testing for rheumatic diseases
Olsen, N. J., Choi, M. Y., & Fritzler, M. J. (2017) · Arthritis Research & Therapy · doi:10.1186/s13075-017-1380-3 · Cited by 63
Shang, X., Ren, L., Sun, G., Yu, T., Yao, Y., Wang, L., Liu, F., Zhang, L., He, X., & Liu, M. (2021) · Immunity Inflammation and Disease · doi:10.1002/iid3.401 · Cited by 51
Mähler, M., Albesa, R., Zohoury, N., Bertolaccini, M. L., Ateka–Barrutia, O., Rodriguez-Garcia, J. L., Norman, G. L., & Khamashta, M. A. (2016) · Lupus · doi:10.1177/0961203316640366 · Cited by 51
Орлов, А. В., Pushkarev, A. V., Znoyko, S. L., Novichikhin, D. O., Bragina, V. A., Gorshkov, B. G., & Nikitin, P. I. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112187 · Cited by 47
Martínez-Prat, L., Nissen, M. J., Lamacchia, C., Bentow, C., Cesana, L., Roux‐Lombard, P., Gabay, C., & Mähler, M. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.01113 · Cited by 45
“This could be due to the differences between the two platforms (30).”
BackgroundMethodInfluential
Metadata
- Authors
- Mahler, M., Bentow, C., Serra, J., & Fritzler, M. J.
- Affiliations
- Werfen Immunoassay Technology Center (ES)
- University of Calgary (CA)
- Venue
- Immunopharmacology and Immunotoxicology
- Publisher
- Informa UK Limited
- Published
- 2015-11-02
- Volume
- 38
- Issue
- 1
- Pages
- 14-20
- ISSN
- 0892-3973 (ISSN-L)
- 1532-2513
- PMC
- PMC4819877
- OpenAlex
- W2116153799
- Cited by
- 47
- References
- 50
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 7 · 2020: 3 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 5
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by-nc-nd
- Locations
- Immunopharmacology and Immunotoxicology (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced Biosensing Techniques and Applications
- Keywords
- autoantibody detection, chemiluminescence immunoassay, autoimmune disease diagnosis, assay performance, follow-up testing
- MeSH terms
- Animals, Autoantibodies, Humans, Luminescent Measurements
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of autoantibodies using chemiluminescence technologies. https://app.cochat.ai/papers/10.3109/08923973.2015.1077461
- The paper
- Mahler, M., Bentow, C., Serra, J., & Fritzler, M. J. (2016). Detection of autoantibodies using chemiluminescence technologies. Immunopharmacology and Immunotoxicology. https://doi.org/10.3109/08923973.2015.1077461
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.