Uptake of Long-Circulating Immunoliposomes, Directed Against Colon Adenocarcinoma Cells, by Liver Metastases of Colon Cancer
The DOI matches its Crossref record.
Abstract
Radiolabeled ([3H]cholesteryloleyl ether) immunoliposomes directed against rat colon adenocarcinoma CC531 cells were prepared by random coupling of a tumor cell-specific antibody, CC52, via a thio ether bond. In vitro binding experiments demonstrated a saturable and specific interaction of CC52-immunoliposomes, which could be inhibited by free non-coupled CC52 but not by irrelevant antibodies. The in vivo targeting potential of CC52-immunoliposomes, which were pegylated to achieve prolonged circulation times, was tested in an established rat liver CC531 metastasis model. Twenty-four hours after injection of the liposomes, 25% of the CC52-immunoliposomes were still present in the blood, which was comparable with the control liposomes (either with or without antibody). Liposomes were mainly taken up from the blood by the liver and the spleen, although hepatic uptake of the immunoliposomes was higher and splenic uptake was lower as compared to liposomes without antibody. Within the metastatic tumor nodules in the liver, uptake of both the CC52-immunoliposomes and non-specific immunoliposomes was significantly higher than that of control liposomes without antibody. Visualization of fluorescently or gold labeled CC52-immunoliposomes revealed that, although targeting to liver metastases was achieved, the immunoliposomes were mostly not associated with tumor cells but rather localized in tumor associated cells, probably macrophages.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent advances with liposomes as pharmaceutical carriers
Torchilin, V. P. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1632 · Cited by 5,282
“The antibody CC52, which is directed against rat colon adenocarcinoma CC531 lines, was attached to PEGylated liposomes and resulted in the specific accumulation of liposomes in a rat model of metastatic CC531 (Ref”
BackgroundNanotechnology: Intelligent Design to Treat Complex Disease
Couvreur, P., & Vauthier, C. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-0284-8 · Cited by 948
Targeted pharmaceutical nanocarriers for cancer therapy and imaging
Torchilin, V. P. (2007) · The AAPS Journal · doi:10.1208/aapsj0902015 · Cited by 762
Multifunctional and stimuli-sensitive pharmaceutical nanocarriers
Torchilin, V. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.09.026 · Cited by 583
“Antibody CC52 against rat colon adenocarcinoma CC531 attached to PEGylated liposomes provided specific accumulation of liposomes in rat model of metastatic CC531 [64].”
BackgroundPassive and Active Drug Targeting: Drug Delivery to Tumors as an Example
Torchilin, V. P. (2010) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-642-00477-3_1 · Cited by 573
Metadata
- Authors
- Kamps, J., Koning, G., Velinova, M., Morselt, H., Wilkens, M., Gorter, A., Donga, J., & Scherphof, G.
- Venue
- Journal of Drug Targeting
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 8
- Issue
- 4
- Pages
- 235-245
- ISSN
- 1026-7158 (ISSN-L)
- 1061-186X
- 1029-2330
- OpenAlex
- W2153601585
- Cited by
- 49
- References
- 0
- FWCI
- 1.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Uptake of Long-Circulating Immunoliposomes, Directed Against Colon Adenocarcinoma Cells, by Liver Metastases of Colon Cancer. https://app.cochat.ai/papers/10.3109/10611860008997902
- The paper
- Kamps, J., Koning, G., Velinova, M., Morselt, H., Wilkens, M., Gorter, A., Donga, J., & Scherphof, G. (2000). Uptake of Long-Circulating Immunoliposomes, Directed Against Colon Adenocarcinoma Cells, by Liver Metastases of Colon Cancer. Journal of Drug Targeting. https://doi.org/10.3109/10611860008997902
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.