Block-copolymer of Polyethylene Glycol and Polylysine as a Carrier of Organic Iodine: Design of Long-circulating Particulate Contrast Medium for X-ray Computed Tomography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In order to obtain small, polymer-stabilized particulate carriers for organic iodine to serve as a contrast agent for X-ray computed tomography (CT) an attempt was made to design a carrier based on polymeric micelles. Here we describe the synthesis of an iodine-containing amphiphilic block-copolymer which can micellize in aqueous solutions. The two blocks of the copolymer consisted of methoxypoly(ethyleneglycol) and poly[epsilon,N-(triiodobenzoyl)-L-lysine]. Upon dispersion in water, the block copolymer formed particles with average diameter 80 nm and iodine content up to 44.7%. The particles start to dissociate to the individual polymeric chains in the concentration range of 0.05-0.5 microM in water at 23 degrees C. Upon intravenous injection at 250 mg of iodine/kg (570 mg of the agent/kg) in rabbits the medium demonstrated exceptional 24 hr half-life in the blood substantiating corona/core structure of the particles with PEG chains protecting the iodine-containing core. The possible use of these particulates as contrast medium for X-ray computed tomography is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Micelles based on AB block copolymers of poly (ethylene oxide) and poly (beta.-benzyl L-aspartate)
Kwon, G., Naito, M., Yokoyama, M., Okano, T., Sakurai, Y., & Kataoka, K. (1993) · Langmuir · doi:10.1021/la00028a012 · Cited by 399
Kabanov, A. V., Chekhonin, V. P., Alakhov, V. Y., Batrakova, E. V., Lebedev, A. S., Melik-Nubarov, N. S., Arzhakov, S. A., Levashov, A. V., Morozov, G. V., Severin, E. S., et al. (1989) · FEBS Letters · doi:10.1016/0014-5793(89)81689-8 · Cited by 296
Watersoluble polymers in medicine
Bader, H., Ringsdorf, H., & Schmidt, B. (1984) · Die Angewandte Makromolekulare Chemie · doi:10.1002/apmc.1984.051230121 · Cited by 291
Cited by
Micellar Nanocarriers: Pharmaceutical Perspectives
Torchilin, V. P. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9132-0 · Cited by 1,910
“At the same time, a variety of monomers may be used to build hydrophobic core-forming blocks: propylene oxide (86,87), L-lysine (88,89), aspartic acid (90,91), b-benzoyl-L-aspartate (92,93), g-benzyl-L-glutamate”
BackgroundInfluentialSelf-citationStructure and design of polymeric surfactant-based drug delivery systems
Torchilin, V. P. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00299-1 · Cited by 1,822
Self-citationPolymeric micelles—A new generation of colloidal drug carriers
Jones, M.-C., & Leroux, J.-C. (1999) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(99)00039-9 · Cited by 1,256
Imaging and drug delivery using theranostic nanoparticles
Janib, S. M., Moses, A. S., & MacKay, J. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.08.004 · Cited by 1,248
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Metadata
- Authors
- Trubetskoy, V. S., Gazelle, G. S., Wolf, G. L., & Torchilin, V. P.
- Venue
- Journal of Drug Targeting
- Publisher
- Informa UK Limited
- Published
- 1997-01
- Volume
- 4
- Issue
- 6
- Pages
- 381-388
- ISSN
- 1026-7158 (ISSN-L)
- 1061-186X
- 1029-2330
- OpenAlex
- W1991972396
- Cited by
- 105
- References
- 3
- FWCI
- 4.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Block-copolymer of Polyethylene Glycol and Polylysine as a Carrier of Organic Iodine: Design of Long-circulating Particulate Contrast Medium for X-ray Computed Tomography. https://app.cochat.ai/papers/10.3109/10611869709017895
- The paper
- Trubetskoy, V. S., Gazelle, G. S., Wolf, G. L., & Torchilin, V. P. (1997). Block-copolymer of Polyethylene Glycol and Polylysine as a Carrier of Organic Iodine: Design of Long-circulating Particulate Contrast Medium for X-ray Computed Tomography. Journal of Drug Targeting. https://doi.org/10.3109/10611869709017895
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.