The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Optimization of artemether-loaded NLC for intranasal delivery using central composite design
Open accessAbstract
The objective of the study was to optimize artemether-loaded nanostructured lipid carriers (ARM-NLC) for intranasal delivery using central composite design. ARM-NLC was prepared by microemulsion method with optimized formulation having particle size of 123.4 nm and zeta potential of -34.4 mV. Differential scanning calorimetry and powder X-ray diffraction studies confirmed that drug existed in amorphous form in NLC formulation. In vitro cytotoxicity assay using SVG p12 cell line and nasal histopathological studies on sheep nasal mucosa indicated the developed formulations were non-toxic and safe for intranasal administration. In vitro release studies revealed that NLC showed sustained release up to 96 h. Ex vivo diffusion studies using sheep nasal mucosa revealed that ARM-NLC had significantly lower flux compared to drug solution (ARM-SOL). Pharmacokinetic and brain uptake studies in Wistar rats showed significantly higher drug concentration in brain in animals treated intranasally (i.n.) with ARM-NLC. Brain to blood ratios for ARM-NLC (i.n.), ARM-SOL (i.n.) and ARM-SOL (i.v.) were 2.619, 1.642 and 0.260, respectively, at 0.5 h indicating direct nose to brain transport of ARM. ARM-NLC showed highest drug targeting efficiency and drug transport percentage of 278.16 and 64.02, respectively, which indicates NLC had better brain targeting efficiency compared to drug solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modeling and comparison of dissolution profiles
Costa, P., & Sousa Lobo, J. M. (2001) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(01)00095-1 · Cited by 5,509
Intranasal delivery of biologics to the central nervous system
Lochhead, J. J., & Thorne, R. G. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.11.002 · Cited by 1,214
Intranasal nanoemulsion based brain targeting drug delivery system of risperidone
Kumar, M., Misra, A., Babbar, A. K., Mishra, A. K., Mishra, P., & Pathak, K. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2008.03.029 · Cited by 435
Sood, S., Jain, K., & Gowthamarajan, K. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2013.09.030 · Cited by 289
Self-citation
Cited by
Nanostructured lipid carriers for site-specific drug delivery
Khosa, A., Reddi, S., & Saha, R. N. (2018) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.04.055 · Cited by 619
Nanostructured lipid carriers (NLC) system: A novel drug targeting carrier
Salvi, V. R., & Pawar, P. (2019) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2019.02.017 · Cited by 456
Doktorovová, S., Kovačević, A. B., Garcia, M. L., & Souto, E. B. (2016) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2016.08.001 · Cited by 293
Nanosystems in nose-to-brain drug delivery: A review of non-clinical brain targeting studies
Pires, P. C., & Santos, A. O. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.11.047 · Cited by 228
Metadata
- Authors
- Jain, K., Sood, S., & Gowthamarajan, K.
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2014-02-10
- Volume
- 22
- Issue
- 7
- Pages
- 940-954
- ISSN
- 1071-7544 (ISSN-L)
- 1521-0464
- OpenAlex
- W2142178060
- Cited by
- 158
- References
- 4
- FWCI
- 3.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimization of artemether-loaded NLC for intranasal delivery using central composite design. https://app.cochat.ai/papers/10.3109/10717544.2014.885999
- The paper
- Jain, K., Sood, S., & Gowthamarajan, K. (2015). Optimization of artemether-loaded NLC for intranasal delivery using central composite design. Drug Delivery. https://doi.org/10.3109/10717544.2014.885999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.