Microneedles for drug delivery: trends and progress
Open accessThe DOI matches its Crossref record; 110 of the 110 references it cites were found in a registry or an index.
Abstract
In recent years, there has been a surge in the research and development of microneedles (MNs), a transdermal delivery system that combines the technology of transdermal patches and hypodermic needles. The needles are in the hundreds of micron length range and therefore allow relatively little or no pain. For example, biodegradable MNs have been researched in the literature and have several advantages compared with solid or hollow MNs, as they produce non-sharp waste and can be designed to allow rapid or slow release of drugs. However, they also pose a disadvantage as successful insertion into the stratum corneum layer of the skin relies on sufficient mechanical strength of the biodegradable material. This review looks at the various technologies developed in MN research and shows the rapidly growing numbers of research papers and patent publications since the first invention of MNs (using time series statistical analysis). This provides the research and industry communities a valuable synopsis of the trends and progress being made in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prausnitz, M. R., & Langer, R. (2008) · Nature Biotechnology · doi:10.1038/nbt.1504 · Cited by 3,517
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521 · cited 4×
“The invention of the MN can overcome this factor as the 208 needles bypass the SC layer, which is the rate dependent layer and can allow large molecular 209 weight proteins to pass into the blood stream [89].”
BackgroundInfluentialCurrent status and future potential of transdermal drug delivery
Prausnitz, M. R., Mitragotri, S., & Langer, R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1304 · Cited by 1,462 · cited 4×
“Furthermore, MN technology has shown to be more advantageous in comparison to the other TDD techniques (Prausnitz et al., 2004), such as the ability to deliver large molecular molecules that are larger than 500 Da (Benson, 2005) and the versatility in the application to allow solid or liquid…”
BackgroundMethodInfluentialMicrofabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346 · cited 12×
“They also differ in shape, ranging from square, circular, flat tipped, sharp tipped, etc. (Henry et al., 1998; Park et al., 2005; Gupta et al., 2009; Swain et al., 2011; Kommareddy et al., 2013; Mansoor et al., 2013; Torrisi et al., 2013; Pierre & Rossetti, 2014).”
BackgroundMethodInfluentialBiodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery
Park, J.-H., Allen, M. G., & Prausnitz, M. R. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.02.002 · Cited by 1,026
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934 · cited 2×
“Methods of DD, such as oral ingestion or hypodermic injections, are considered to be the most common forms of drug administration (Davis et al., 2004; Escobar-Chávez et al., 2011).”
BackgroundTransdermal Drug Delivery: Penetration Enhancement Techniques
Benson, H. (2005) · Current Drug Delivery · doi:10.2174/1567201052772915 · Cited by 712 · cited 9×
“…in comparison to the other TDD techniques (Prausnitz et al., 2004), such as the ability to deliver large molecular molecules that are larger than 500 Da (Benson, 2005) and the versatility in the application to allow solid or liquid formulations to be developed for disease specific applications.”
BackgroundMethodInfluentialOvercoming the Stratum Corneum: The Modulation of Skin Penetration
Trommer, H., & Neubert, R. H. H. (2006) · Skin Pharmacology and Physiology · doi:10.1159/000091978 · Cited by 572 · cited 1×
“There are several physical methods that have been used in conjunction with MN technology to increase skin permeation (Hilt & Peppas, 2005; Trommer & Neubert, 2006; NavaArzaluz et al., 2012).”
MethodTransdermal Delivery of Insulin Using Microneedles in Vivo
Martanto, W., Davis, S. P., Holiday, N. R., Wang, J., Gill, H. S., & Prausnitz, M. R. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000029282.44140.2e · Cited by 521 · cited 3×
“Ita, 2014; Nalwa, 2014; Wolff, 2014) and specific drug deliveries, such as insulin (Martanto et al., 2004; Zahn et al., 2005; Ito et al., 2006; Khanna et al., 2008; Taylor & Sahota, 2013; Bronger, 2014; Natayan, 2014).”
BackgroundSkin thickness of Korean adults
Y., L., & K., H. (2002) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-002-0034-5 · Cited by 474 · cited 4×
“Therefore, 167 analysis into skin thickness is important, as outlined in a study of skin thickness of Korean 168 males and females conducted by Lee and Hwang [74].”
BackgroundInfluential
Cited by
Microneedles: A smart approach and increasing potential for transdermal drug delivery system
Waghule, T., Singhvi, G., Dubey, S. K., Pandey, M. M., Gupta, G., Singh, M., & Dua, K. (2019) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2018.10.078 · Cited by 1,260
Transdermal Delivery of Drugs with Microneedles—Potential and Challenges
Ita, K. (2015) · Pharmaceutics · doi:10.3390/pharmaceutics7030090 · Cited by 530
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Current trends in polymer microneedle for transdermal drug delivery
Ahmed Saeed AL-Japairai, K., Mahmood, S., Hamed Almurisi, S., Reddy Venugopal, J., Rebhi Hilles, A., Azmana, M., & Raman, S. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119673 · Cited by 448
Hydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Recent advances of controlled drug delivery using microfluidic platforms
Sanjay, S. T., Zhou, W., Dou, M., Tavakoli, H., Ma, L., Xu, F., & Li, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.09.013 · Cited by 365
Wei, J. C. J., Edwards, G. A., Martin, D. J., Huang, H., Crichton, M. L., & Kendall, M. A. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-15830-7 · Cited by 301
Transdermal electroosmotic flow generated by a porous microneedle array patch
Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M. (2021) · Nature Communications · doi:10.1038/s41467-021-20948-4 · Cited by 260
Microneedle-Based Delivery: An Overview of Current Applications and Trends
Guillot, A. J., Cordeiro, A. S., Donnelly, R. F., Montesinos, M. C., Garrigues, T. M., & Melero, A. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12060569 · Cited by 254
Long-acting reversible contraception by effervescent microneedle patch
Li, W., Tang, J., Terry, R. N., Li, S., Brunie, A., Callahan, R. L., Noel, R. K., Rodríguez, C. A., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Science Advances · doi:10.1126/sciadv.aaw8145 · Cited by 248
Microelectromechanical Systems (MEMS) for Biomedical Applications
Chircov, C., & Grumezescu, A. M. (2022) · Micromachines · doi:10.3390/mi13020164 · Cited by 243
“In this context, microneedles might be considered a microscaled hybrid between transdermic patches and hypodermic syringes, as they are able to ensure transport pathways between the microneedle array and the biological membrane [149,150].”
BackgroundInfluentialMicroneedles: Characteristics, Materials, Production Methods and Commercial Development
Tucak, A., Sirbubalo, M., Hindija, L., Rahić, O., Hadžiabdić, J., Muhamedagić, K., Čekić, A., & Vranić, E. (2020) · Micromachines · doi:10.3390/mi11110961 · Cited by 231
“23 billion in 2019 [17], the biggest problem is the limited number of APIs (less than 20) that are suitable for transdermal delivery [8,18].”
BackgroundInfluentialPolymeric microneedles for controlled transdermal drug delivery
Singh, P., Carrier, A., Chen, Y., Lin, S., Wang, J., Cui, S., & Zhang, X. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.10.022 · Cited by 229
Rapidly dissolving polymeric microneedles for minimally invasive intraocular drug delivery
Thakur, R. R. S., Tekko, I. A., Al-Shammari, F., Ali, A. A., McCarthy, H., & Donnelly, R. F. (2016) · Drug Delivery and Translational Research · doi:10.1007/s13346-016-0332-9 · Cited by 217
Topical drug delivery systems: a patent review
Singh Malik, D., Mital, N., & Kaur, G. (2016) · Expert Opinion on Therapeutic Patents · doi:10.1517/13543776.2016.1131267 · Cited by 192
“In addition, the high cost of fabrication hinders the large-scale production of microneedles.[48] Therefore,”
BackgroundMicroalgae Microneedle Supplies Oxygen for Antiphotoaging Treatment
Wang, Z., Kwong, C. H. T., Zhao, H., Ding, Y.-F., Gao, C., Zhang, D., Cheng, Q., Wei, J., Zhang, Q.-W., & Wang, R. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00192 · Cited by 19
Metadata
- Authors
- Cheung, K., & Das, D. B.
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2014-12-23
- Volume
- 23
- Issue
- 7
- Pages
- 2338-2354
- ISSN
- 1071-7544 (ISSN-L)
- 1521-0464
- OpenAlex
- W2085338797
- Cited by
- 244
- References
- 110
- FWCI
- 5.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.