A Novel Amperometric Biosensor Based on Banana Peel ( Musa cavendish ) Tissue Homogenate for Determination of Phenolic Compounds
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
In this study the biosensor was constructed by immobilizing tissue homogenate of banana peel onto a glassy carbon electrode surface. Effects of immobilization materials amounts, effects of pH, buffer concentration and temperature on biosensor response were studied. In addition, the detection ranges of 13 phenolic compounds were obtained with the help of the calibration graphs. Storage stability, repeatability of the biosensor, inhibitory effect and sample applications were also investigated. A typical calibration curve for the sensor revealed a linear range of 10-80 microM catechol. In reproducibility studies, variation coefficient and standard deviation were calculated as 2.69%, 1.44 x 10(-3) microM, respectively.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Polyphenols: Chemistry, dietary sources, metabolism, and nutritional significance
Bravo, L. (2009) · Nutrition Reviews · doi:10.1111/j.1753-4887.1998.tb01670.x · Cited by 4,030
Polyphenol oxidases and peroxidases in fruits and vegetables
Vámos‐Vigyázó, L., & Haard, N. F. (1981) · C R C Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398109527312 · Cited by 1,005
Encyclopedia of analytical science
(2005) · Choice Reviews Online · doi:10.5860/choice.43-0032 · Cited by 917
Are tannins a double-edged sword in biology and health?
Chung, K.-T., Wei, C.-I., & Johnson, M. G. (1998) · Trends in Food Science & Technology · doi:10.1016/s0924-2244(98)00028-4 · Cited by 306
Naturally Occurring Food Toxicants: Phenolic Substances of Plant Origin Common in Foods
Singleton, V. L. (1981) · Advances in Food Research · doi:10.1016/s0065-2628(08)60299-2 · Cited by 281
Biosensors for environmental applications
Rogers, K. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96929-s · Cited by 254
Method To Assay the Concentrations of Phenolic Constituents of Biological Interest in Wines
Goldberg, D. M., Tsang, E., Karumanchiri, A., Diamandis, E. P., Soleas, G., & Ng, E. (1996) · Analytical Chemistry · doi:10.1021/ac951083i · Cited by 240
VEDRINE, C. (2003) · Talanta · doi:10.1016/s0039-9140(02)00540-4 · Cited by 174
Campuzano, S., Serra, B., Pedrero, M., Villena, F., & Pingarrón, J. M. (2003) · Analytica Chimica Acta · doi:10.1016/s0003-2670(03)00919-x · Cited by 155
Tea components: Antimutagenic and anticarcinogenic effects
Mukhtar, H., Wang, Z. Y., Katiyar, S. K., & Agarwal, R. (1992) · Preventive Medicine · doi:10.1016/0091-7435(92)90042-g · Cited by 149
An amperometric biosensor for polyphenolic compounds in red wine
Gomes, S. A. S. S., Nogueira, J. M. F., & Rebelo, M. J. F. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.05.013 · Cited by 142
Properties of polyphenol oxidase from Anamur banana (Musa cavendishii)
Ünal, M. Ü. (2005) · Food Chemistry · doi:10.1016/j.foodchem.2005.10.048 · Cited by 135
Rosatto, S. S., Kubota, L. T., & Neto, G. D. O. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00168-3 · Cited by 132
Rajesh, R., Takashima, W., & Kaneto, K. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.04.028 · Cited by 129
Yu, J., Liu, S., & Ju, H. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00227-6 · Cited by 114
Romani, A., Minunni, M., Mulinacci, N., Pinelli, P., Vincieri, F. F., Del Carlo, M., & Mascini, M. (2000) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf990767e · Cited by 102
Thick film sensors based on laccases from different sources immobilized in polyaniline matrix
Tımur, S., Pazarlıoǧlu, N. K., Pilloton, R., & Telefoncu, A. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.07.018 · Cited by 98
Yang, S., Li, Y., Jiang, X., Chen, Z., & Lin, X. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.07.035 · Cited by 88
Morales, S. E., & Cela, R. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00581-1 · Cited by 78
Amperometric Biosensor for Polyphenol Based on Horseradish Peroxidase Immobilized on Gold Electrodes
Imabayashi, S.-I., Kong, Y.-T., & Watanabe, M. (2001) · Electroanalysis · doi:10.1002/1521-4109(200104)13:5<408::aid-elan408>3.0.co;2-2 · Cited by 68
Masqué, N., Pocurull, E., Marcé, R. M., & Borrull, F. (1998) · Chromatographia · doi:10.1007/bf02466578 · Cited by 66
Preparative biochemistry & biotechnology
Online, T. F. (1996) · Cited by 64
Direct determination of sulfite in food samples by a biosensor based on plant tissue homogenate
Sezgintürk, M. K., & Dinçkaya, E. (2004) · Talanta · doi:10.1016/j.talanta.2004.08.037 · Cited by 59
Biosensors for phenolic compounds: The catechol as a substrate model
Portaccio, M., Martino, S. D., Maiuri, P., Durante, D., Luca, P. D., Lepore, M. A., Bencivenga, U., Rossi, S., Maio, A. D., & Mita, D. G. (2006) · Journal of Molecular Catalysis B Enzymatic · doi:10.1016/j.molcatb.2006.05.002 · Cited by 56
Determination of flavanols in beers with tissue biosensors
Eggins, B. R., Hickey, C., Toft, S. A., & Zhou, D. M. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00162-1 · Cited by 53
Topçu, S., Sezgintürk, M. K., & Dinçkaya, E. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.03.011 · Cited by 48
Fiehn, O., & Jekel, M. (1997) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)00057-5 · Cited by 48
Makower, A., Eremenko, A. V., Streffer, K., Wollenberger, U., & Scheller, F. W. (1996) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199601)65:1<39::aid-jctb377>3.0.co;2-q · Cited by 45
Preston, J. S., & du Preez, A. C. (1996) · Journal of Chemical Technology & Biotechnology · doi:10.1002/(sici)1097-4660(199601)65:1<21::aid-jctb382>3.0.co;2-e · Cited by 42
Sezgintürk, M. K., & Dinçkaya, E. (2003) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2003.08.012 · Cited by 34
Sezgintürk, M. K., & Dinçkaya, E. (2003) · Talanta · doi:10.1016/s0039-9140(02)00539-8 · Cited by 32
Özsöz, M., Erdem, A., Kilinç, E., & Gokgunnec, L. (1996) · Electroanalysis · doi:10.1002/elan.1140080210 · Cited by 30
Yu, J., & Ju, H. (2004) · Electroanalysis · doi:10.1002/elan.200302951 · Cited by 29
Analysis of Alcohols and Phenols with a Newly Designed Gas Chromatographic Detector
Kishi, H., Arimoto, H., & Fujii, T. (1998) · Analytical Chemistry · doi:10.1021/ac980138o · Cited by 18
Evaluation of Nielsen-Kryger Steam Distillation Technique for Recovery of Phenols from Soil
Narang, A. S., Vernoy, C., & Eadon, G. A. (1983) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/66.6.1330 · Cited by 17
Immobilized Jerusalem Artichoke (Helianthus tuberosus) Tissue Electrode for Phenol Detection
Demirkol, D. O., Tımur, S., & Telefoncu, A. (2004) · Artificial Cells Blood Substitutes and Biotechnology · doi:10.1081/bio-120037836 · Cited by 9
Teke, M., Sezgintürk, M. K., Dinçkaya, E., & Telefoncu, A. (2007) · Preparative Biochemistry & Biotechnology · doi:10.1080/10826060701774346 · Cited by 6
Research works printed but not linked: 2
- Vogel, V. (1989). Textbook of Quantitative Chemical Analysis, Longman, UK, 707.
- 10.1016/j.bios.2004.03.011 · DOI
Cited by
Valorization of banana peel: a biorefinery approach
Pathak, P. D., Mandavgane, S. A., & Kulkarni, B. D. (2016) · Reviews in Chemical Engineering · doi:10.1515/revce-2015-0063 · Cited by 49
Rahimi‐Mohseni, M., Raoof, J. B., Ojani, R., Aghajanzadeh, T. A., & Hashkavayi, A. B. (2018) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2018.02.060 · Cited by 48
Exploration of the Potential Application of Banana Peel for Its Effective Valorization: A Review
Bishnoi, S., Sharma, S., & Agrawal, H. (2023) · Indian Journal of Microbiology · doi:10.1007/s12088-023-01100-w · Cited by 45
Asadian, E., Abbaszadeh, S., Ghorbani-Bidkorpeh, F., Rezaei, S., Xiao, B., Santos, H. A., & Shahbazi, M. (2025) · Biomaterials Science · doi:10.1039/d4bm00982g · Cited by 20
Asav, E. (2021) · TURKISH JOURNAL OF CHEMISTRY · doi:10.3906/kim-2012-69 · Cited by 17
Metadata
- Authors
- Ozcan, H. M., & Sagiroglu, A.
- Affiliations
- Trakya University, Faculty of Science, Department of Chemistry, Section of Biochemistry, Edirne, Turkey
- Venue
- Artificial Cells, Blood Substitutes, and Biotechnology
- Publisher
- Informa UK Limited
- Published
- 2010-04-09
- Volume
- 38
- Issue
- 4
- Pages
- 208-214
- ISSN
- 1055-7172 (ISSN-L)
- 1073-1199
- 1532-4184
- OpenAlex
- W1986005394
- Cited by
- 11
- References
- 36
- Citations by year
- 2024: 2 · 2023: 1 · 2021: 2 · 2018: 2 · 2017: 1 · 2016: 1 · 2014: 1 · 2013: 1
- FWCI
- 0.25
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Artificial Cells Blood Substitutes and Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Trakya University's Institutional Open Access System (Trakya University) (submittedVersion)
- Funders
- Trakya Üniversitesi
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Enzyme Catalysis and Immobilization
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- amperometric biosensor, banana peel, Musa cavendish, tissue homogenates, phenolic compounds, catechol, enzyme immobilization, glassy carbon electrode, biosensor stability
- MeSH terms
- Beverages, Buffers, Calibration, Catechol Oxidase, Electrochemistry, Enzyme Inhibitors, Gelatin, Glutaral, Hydrogen-Ion Concentration, Metals, Phenols, Plant Extracts, Temperature, Reproducibility of Results, Biosensing Techniques, Linear Models, Plant Epidermis, Musa, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.