CoChat

A New Non-Thrombogenic Surface Prepared by Selective Covalent Binding of Heparin Via a Modified Reducing Terminal Residue

Larm, O., Larsson, R., Olsson, P. · 1983 · Biomaterials, Medical Devices, and Artificial Organs
Cited by 437

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A new method for the covalent binding of heparin to artificial surfaces has been developed. The heparinized surface releases insignificant amounts of heparin and can be regarded as stable. The blood contact properties as studied in vitro revealed that the surface was highly thromboresistant in terms of reduced platelet adhesion, surface catalyzed adsorption and inhibition of thrombin and capacity to prevent clotting of nonanticoagulated blood.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/10731198309118804

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 437

Metadata

Authors
Larm, O., Larsson, R., & Olsson, P.
Venue
Biomaterials, Medical Devices, and Artificial Organs
Published
1983-01
Volume
11
Issue
2-3
Pages
161-173
ISSN
0090-5488 (ISSN-L)
OpenAlex
W2142076308
Cited by
437
References
2
FWCI
3.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.