The effect of visual and haptic feedback on computer-assisted needle insertion
The DOI matches its Crossref record; 15 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: We present a study evaluating the effects of visual and haptic feedback on human performance in a needle insertion task. MATERIALS AND METHODS: A one-degree-of-freedom needle insertion simulator with a three-layer tissue model (skin, fat and muscle) was used in perceptual experiments. The objective of the 14 subjects was to detect the puncture of each tissue layer using varying haptic and visual cues. Performance was measured by overshoot error-the distance traveled by the virtual needle after puncture. RESULTS: Without force feedback, real-time visual feedback reduced error by at least 87% in comparison to static image overlay. Force feedback, in comparison to no force feedback, reduced puncture overshoot by at least 52% when visual feedback was absent or limited to static image overlay. A combination of force and visual feedback improved performance, especially for tissues with low stiffness, by at least 43% with visual display of the needle position, and by at least 67% with visual display of layer deflection. CONCLUSION: Real-time image overlay significantly enhances controlled puncture during needle insertion. Force feedback may not be necessary except in circumstances where visual feedback is limited.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Needle insertion modeling and simulation
DiMaio, S. P., & Salcudean, S. E. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817044 · Cited by 518 · cited 2×
“Accurate mechanical models [8,12] could present graphical feedback reflecting the estimated state of the tissues impacted by needle insertion.”
BackgroundMethodTactile Display of Vibratory Information in Teleoperation and Virtual Environments
Kontarinis, D. A., & Howe, R. D. (1995) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.1995.4.4.387 · Cited by 251 · cited 1×
“…and Howe performed a teleoperated experiment in which subjects were asked to penetrate a thin membrane with a needle held by a slave manipulator, while being provided with combinations of visual (manipulator exposed / hidden), filtered force, and vibratory feedback at the master manipulator [4].”
BackgroundThao, D., Annaswamy, T. M., & Srinivasan, M. A. (2001) · Studies in health technology and informatics · doi:10.3233/978-1-60750-925-7-97 · Cited by 117
Surgical assist robot for the active navigation in the intraoperative MRI: hardware design issues
Chinzei, K., Hata, N., Jolesz, F. A., & Kikinis, R. (2002) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2000.894690 · Cited by 85 · cited 1×
“Chinzei et al. have suggested a surgical assistant robot for use with intraoperative MRI (which offers exceptional soft tissue discrimination) for instrument insertion in procedures such as prostate tumor biopsy [ 2 ].”
MethodSystem for MR Image–guided Prostate Interventions: Canine Study
Susil, R. C., Krieger, A., Derbyshire, J. A., Tanács, A., Whitcomb, L. L., Fichtinger, G., & Atalar, E. (2003) · Radiology · doi:10.1148/radiol.2283020911 · Cited by 84 · cited 1×
“Third, there are new systems in development to allow real-time highquality images during needle insertion procedures, such as robot-assisted therapy delivery under MRI guidance [ 11 ].”
BackgroundSensorless planning for medical needle insertion procedures
Alterovitz, R., Goldberg, K., Pouliot, J., Taschereau, R., & Hsu, I.-C. J. (2004) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2003.1249671 · Cited by 83 · cited 1×
“Alterovitz et al. [13] have developed a method for pre-operative planning with tissue deformation determined by a mechanical model, but further work is required to obtain models with sufficient patient-specific accuracy.”
MethodSchemes for the identification of tissue types and boundaries at the tool point for surgical needles
Brett, P. N., Harrison, A. J., & Thomas, T. A. (2000) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.826856 · Cited by 80 · cited 1×
“Other approaches use force data acquired during ex vivo needle insertions into animal models [ 9 ] and MR imaging to determine layer anatomy [10].”
MethodTactile Display of High-Frequency Information in Teleoperation and Virtual Environments.
Kontarinis, D. A., & Howe, R. D. (1995) · Cited by 77
Baumann, S. B., Noll, D. C., Kondziolka, D. S., Schneider, W., Nichols, T. E., Mintun, M. A., Lewine, J. D., Yonas, H., Orrison, W. W., & Sclabassi, R. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:4<242::aid-igs7>3.0.co;2-a · Cited by 56 · cited 1×
“ISSN 1092-9088 print=ISSN 1097-0150 online #2004 Taylor & Francis Group Ltd DOI: 10.1080=10929080500190441 with MRI-guided neurosurgery [ 3 ].”
InfluentialForce models for needle insertion created from measured needle puncture data.
Holton, L. (2001) · PubMed · Cited by 42
Development of an MRI-Compatible Needle Insertion Manipulator for Stereotactic Neurosurgery
Masamune, K., Kobayashi, E., Masutani, Y., Suzuki, M., Dohi, T., Iseki, H., & Takakura, K. (1995) · Computer Aided Surgery · doi:10.3109/10929089509106330 · Cited by 41
Force feedback for virtual reality based minimally invasive surgery simulator.
Baumann, R., Glauser, D., Tappy, D., Baur, C., & Clavel, R. (1996) · PubMed · Cited by 38
Realistic force reflection in a spine biopsy simulator
Kwon, D., Kyung, K., Kwon, S. M., Ra, J. B., Park, H. W., Kang, H. S., Zeng, J., & Cleary, K. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2001.932799 · Cited by 37
Medially Based Meshing with Finite Element Analysis of Prostate Deformation
Crouch, J. R., Pizer, S. M., Chaney, E. L., & Zaider, M. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39899-8_14 · Cited by 19 · cited 1×
“Accurate mechanical models [8, 12 ] could present graphical feedback reflecting the estimated state of the tissues impacted by needle insertion.”
BackgroundVisually guided spine biopsy simulator with force feedback
Ra, J. B., Kwon, S. M., Kim, J. K., Yi, J., Kim, K. H., Park, H. W., Kyung, K., Kwon, D., Kang, H. S., Jiang, L., et al. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.428072 · Cited by 8
Research works printed but not linked: 1
- Dang T, 1996, Studies in Health Technology and Informatics, 29, 564
Cited by
Haptics in minimally invasive surgery – a review
Westebring – van der Putten, E. P., Goossens, R. H. M., Jakimowicz, J. J., & Dankelman, J. (2008) · Minimally Invasive Therapy & Allied Technologies · doi:10.1080/13645700701820242 · Cited by 328
“In a VRT needle task, force feedback in combination with visual feedback of needle position resulted in better performance than one of the two feedback systems alone (107).”
MethodIssues in closed-loop needle steering
Rossa, C., & Tavakoli, M. (2017) · Control Engineering Practice · doi:10.1016/j.conengprac.2017.03.004 · Cited by 115
“to the surgeon in the form of tactile haptic feedback [50, 224, 225].”
BackgroundAchieving Haptic Perception in Forceps’ Manipulator Using Pneumatic Artificial Muscle
Li, H., Kawashima, K., Tadano, K., Ganguly, S., & Nakano, S. (2011) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2011.2163415 · Cited by 105
Meli, L., Pacchierotti, C., & Prattichizzo, D. (2017) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1809 · Cited by 83
“Gerovich et al. 27 showed that haptic feedback, in comparison to not providing any force feedback, reduced puncture overshoot by at least 52% when visual feedback was absent or limited to static image overlay.”
BackgroundInstrumental action: the timely exchange of implements during surgical operations
Svensson, M., Heath, C., & Luff, P. (2007) · Springer eBooks · doi:10.1007/978-1-84800-031-5_3 · Cited by 76
“…surgeons so they can learn the 'feel of an operation' and the introduction of robotic and other sophisticated technologies to support medical interventions, it is not surprising that there has been considerable interest in haptic technologies in the surgical setting (e.g. Gerovich et al 2004).”
Background
Metadata
- Authors
- Gerovich, O., Marayong, P., & Okamura, A. M.
- Affiliations
- Eternity Bioscience (United States) (US)
- Johns Hopkins University (US)
- Corresponding author
- Okamura, Allison M.
- Venue
- Computer Aided Surgery
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 9
- Issue
- 6
- Pages
- 243-249
- ISSN
- 1092-9088 (ISSN-L)
- 1097-0150
- OpenAlex
- W2020255928
- Cited by
- 118
- References
- 16
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 4 · 2019: 1 · 2018: 7 · 2017: 11 · 2016: 7 · 2015: 5 · 2014: 7 · 2013: 11 · 2012: 7
- FWCI
- 4.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Computer Aided Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- needle insertion, haptic feedback, force feedback, visual feedback, computer-assisted surgery, tissue stiffness
- MeSH terms
- Adult, Computer-Assisted Instruction, Computer Simulation, Feedback, Female, Humans, Male, Models, Anatomic, Needles, Preoperative Care, Punctures, Task Performance and Analysis, User-Computer Interface
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.