The DOI matches its Crossref record.
Fluoroscopy as an Imaging Means for Computer-Assisted Surgical Navigation
Open accessAbstract
Objective: Intraoperative fluoroscopy is a valuable tool for visualizing underlying bone and surgical tool positions in orthopedic procedures. Disadvantages of this technology include the need for continued radiation exposure for visual control, and cumbersome means of alignment. The purpose of this article was to highlight a new concept for a computer-assisted freehand navigation system that uses single intraoperatively acquired fluoroscopic images as a basis for real-time navigation of surgical toolsMaterials and Methods: Optoelectronic markers are placed on surgical tools, a patient reference, and the fluoroscope to track their position in space. Projection properties of the fluoro-scope are acquired through an initial precalibration procedure using a tracked radiopaque phantom grid. Corrections are applied to compensate for both the fluoroscope's image intensifier distortions and the mechanical bending of the C-arm frame. This enables real-time simulation of surgical tool positions simultaneously in several single-shot fluoroscopic images. In addition, through optoelec-tronically tracked digitization of a target viewpoint, the fluoroscope can be numerically aligned at precise angles relative to the patient without any X-ray exposureResults: This article shows the feasibility of this technology through its use in cadaver trials to perform the difficult task of distal locking of femoral nails.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Robotic motion compensation for respiratory movement during radiosurgery
Schweikard, A., Glosser, G., Bodduluri, M., Murphy, M. J., & Adler, J. R. (2000) · Computer Aided Surgery · doi:10.1002/1097-0150(2000)5:4<263::aid-igs5>3.0.co;2-2 · Cited by 393
Bone-mounted miniature robot for surgical procedures: concept and clinical applications
Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817075 · Cited by 292
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Precision of computer-assisted core decompression drilling of the femoral head
Beckmann, J., Goetz, J., Baethis, H., Kalteis, T., Grifka, J., & Perlick, L. (2006) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-006-0155-0 · Cited by 27
Metadata
- Authors
- Hofstetter, R., Slomczykowski, M., Sati, M., & Nolte, L.-P.
- Venue
- Computer Aided Surgery
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 4
- Issue
- 2
- Pages
- 65-76
- ISSN
- 1092-9088 (ISSN-L)
- 1097-0150
- OpenAlex
- W4249564264
- Cited by
- 172
- References
- 0
- FWCI
- 9.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluoroscopy as an Imaging Means for Computer-Assisted Surgical Navigation. https://app.cochat.ai/papers/10.3109/10929089909148161
- The paper
- Hofstetter, R., Slomczykowski, M., Sati, M., & Nolte, L.-P. (1999). Fluoroscopy as an Imaging Means for Computer-Assisted Surgical Navigation. Computer Aided Surgery. https://doi.org/10.3109/10929089909148161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.