The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Bone-mounted miniature robot for surgical procedures: concept and clinical applications
Abstract
This paper presents a new approach to robot-assisted spine and trauma surgery in which a miniature robot is directly mounted on the patient's bony structure near the surgical site. The robot is designed to operate in a semiactive mode to precisely position and orient a drill or a needle in various surgical procedures. Since the robot forms a single rigid body with the anatomy, there is no need for immobilization or motion tracking, which greatly enhances and simplifies the robot's registration to the target anatomy. To demonstrate this concept, we developed the MiniAture Robot for Surgical procedures (MARS), a cylindrical 5/spl times/7 cm/sup 3/, 200-g, six-degree-of-freedom parallel manipulator. We are currently developing two clinical applications to demonstrate the concept: 1) surgical tools guiding for spinal pedicle screws placement; and 2) drill guiding for distal locking screws in intramedullary nailing. In both cases, a tool guide attached to the robot is positioned at a planned location with a few intraoperative fluoroscopic X-ray images. Preliminary in-vitro experiments demonstrate the feasibility of this concept.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robot Analysis: The Mechanics of Serial and Parallel Manipulators
Tsai, L. (1999) · Cited by 1,848
A Steady-Hand Robotic System for Microsurgical Augmentation
Taylor, R., Jensen, P., Whitcomb, L., Barnes, A., Kumar, R., Stoianovici, D., Gupta, P., Wang, Z., Dejuan, E., & Kavoussi, L. (1999) · The International Journal of Robotics Research · doi:10.1177/02783649922067807 · Cited by 528
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1×
“817075 • ability to work according to preplanned image-based program; • reduction of the surgeon’s hand tremor ([18], [26]); • ability to operate in remotely manipulated minimally invasive procedures; • reduction of the surgeon and operating staff radiation exposure ([20], [25]); • reduction of operating room staff.”
BackgroundState of the art in surgical robotics: Clinical applications and technology challenges
Cleary, K., & Nguyen, C. (2001) · Computer Aided Surgery · doi:10.1002/igs.10019 · Cited by 238
Fluoroscopy as an imaging means for computer-assisted surgical navigation
Hofstetter, R., Slomczykowski, M., Sati, M., & Nolte, L. –. (1999) · Computer Aided Surgery · doi:10.1002/(sici)1097-0150(1999)4:2<65::aid-igs1>3.0.co;2-y · Cited by 221
Fluoroscopy as an Imaging Means for Computer-Assisted Surgical Navigation
Hofstetter, R., Slomczykowski, M., Sati, M., & Nolte, L.-P. (1999) · Computer Aided Surgery · doi:10.3109/10929089909148161 · Cited by 172
Computer-aided fixation of spinal implants
Nolte, L.-P., Visarius, H., Arm, E., Langlotz, F., Schwarzenbach, O., & Zamorano, L. J. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:2<88::aid-igs3>3.0.co;2-h · Cited by 167
The Rationales of Interlocking Nailing of the Femur, Tibia, and Humerus: An Overview
Brumback, R. J. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199603000-00036 · Cited by 147
Interlocking medullary nails ? Radiation doses in distal targeting
Skjeldal, S., & Backe, S. (1987) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/bf00452206 · Cited by 70
Robust Automatic C-Arm Calibration for Fluoroscopy-Based Navigation: A Practical Approach
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2002) · Lecture notes in computer science · doi:10.1007/3-540-45787-9_8 · Cited by 64
Self-citation
Cited by
Devito, D. P., Kaplan, L., Dietl, R., Pfeiffer, M., Horne, D., Silberstein, B., Hardenbrook, M., Kiriyanthan, G., Barzilay, Y., Bruskin, A., et al. (2010) · Spine · doi:10.1097/brs.0b013e3181d323ab · Cited by 407
Self-citationNavigation and Robotics in Spinal Surgery: Where Are We Now?
Overley, S. C., Cho, S. K., Mehta, A. I., & Arnold, P. M. (2017) · Neurosurgery · doi:10.1093/neuros/nyw077 · Cited by 327
Metadata
- Authors
- Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y.
- Venue
- IEEE Transactions on Robotics and Automation
- Published
- 2003-10
- Volume
- 19
- Issue
- 5
- Pages
- 893-901
- ISSN
- 1042-296X (ISSN-L)
- OpenAlex
- W2143047169
- Cited by
- 292
- References
- 10
- FWCI
- 34.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bone-mounted miniature robot for surgical procedures: concept and clinical applications. https://app.cochat.ai/papers/10.1109/tra.2003.817075
- The paper
- Shoham, M., Burman, M., Zehavi, E., Joskowicz, L., Batkilin, E., & Kunicher, Y. (2003). Bone-mounted miniature robot for surgical procedures: concept and clinical applications. IEEE Transactions on Robotics and Automation. https://doi.org/10.1109/tra.2003.817075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.