CoChat

Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers

Antfolk, Christian, Cipriani, Christian, Carrozza, Maria Chiara, Balkenius, Christian, Björkman, Anders, Lundborg, Göran, Rosén, Birgitta, Sebelius, Fredrik · 2013 · Disability and Rehabilitation: Assistive Technology
Cited by 52

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: This study explores the possibilities of transferring peripheral tactile stimulations from an artificial hand to the forearm skin. METHOD: A tactile display applied to the forearm skin was used to transfer tactile input to the forearm from various locations on a hand displayed on a computer screen. Discernment of location, levels of pressure and a combination of the two in simulated functional grips was tested to quantify the participants' ability to accurately perceive the tactile stimulations presented. Ten participants (5 forearm amputees and 5 able-bodied volunteers) unfamiliar with the equipment participated in the three-stage experiments comprising a learning session with vision, a reinforced learning session without vision and a validation session without vision. RESULTS: The location discernment accuracy was high in both groups (75.2% and 89.6% respectively). The capacity to differentiate between three different levels of pressure was also high (91.7% and 98.1% respectively in the two groups). Recognition of simulated grip was slightly more difficult with the groups scoring 58.7% and 68.0% respectively for accuracy in the validation session. CONCLUSIONS: This study demonstrates that it is possible, following a brief training period, to transfer tactile input from an artificial hand to the forearm skin. The level of accuracy was lower for the more complex task, simulated grip recognition, possibly because this represents a more complex task requiring higher order brain functions. These results could form the basis for developing sensory feedback in hand prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/17483107.2012.713435

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 52

Metadata

Authors
Antfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F.
Venue
Disability and Rehabilitation: Assistive Technology
Published
2012-08-28
Volume
8
Issue
3
Pages
249-254
ISSN
  • 1748-3107 (ISSN-L)
  • 1748-3115
OpenAlex
W2006327366
Cited by
52
References
6
FWCI
2.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers. https://app.cochat.ai/papers/10.3109/17483107.2012.713435
The paper
Antfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F. (2013). Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers. Disability and Rehabilitation: Assistive Technology. https://doi.org/10.3109/17483107.2012.713435

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.