Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: This study explores the possibilities of transferring peripheral tactile stimulations from an artificial hand to the forearm skin. METHOD: A tactile display applied to the forearm skin was used to transfer tactile input to the forearm from various locations on a hand displayed on a computer screen. Discernment of location, levels of pressure and a combination of the two in simulated functional grips was tested to quantify the participants' ability to accurately perceive the tactile stimulations presented. Ten participants (5 forearm amputees and 5 able-bodied volunteers) unfamiliar with the equipment participated in the three-stage experiments comprising a learning session with vision, a reinforced learning session without vision and a validation session without vision. RESULTS: The location discernment accuracy was high in both groups (75.2% and 89.6% respectively). The capacity to differentiate between three different levels of pressure was also high (91.7% and 98.1% respectively in the two groups). Recognition of simulated grip was slightly more difficult with the groups scoring 58.7% and 68.0% respectively for accuracy in the validation session. CONCLUSIONS: This study demonstrates that it is possible, following a brief training period, to transfer tactile input from an artificial hand to the forearm skin. The level of accuracy was lower for the more complex task, simulated grip recognition, possibly because this represents a more complex task requiring higher order brain functions. These results could form the basis for developing sensory feedback in hand prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Gibson, J. J. (1962) · Psychological Review · doi:10.1037/h0046962 · Cited by 1,435
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 1×
“Users of prosthetic hands have indicated in surveys that they would like enhanced sensory feedback from their prosthesis [12,13].”
BackgroundResults of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257
Patterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 1×
“[24] used a vibrotactile and pressure cuff to provide sensory feedback in able-bodied volunteers.”
MethodRiso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Self-citationA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“There are a variety of feedback methods that currently have been deployed within literature including the use of temperature [39], [40], vibration [41]–[51], mechanical pressure and skin stretching [15], [16], [52]–[57], electrotactile stimulation [58]–[71], audio feedback [72]–[74], and augmented reality [75], [76].”
BackgroundMethodForearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Perovic, M., Stevanovic, M., Jevtic, T., Strbac, M., Bijelic, G., Vucetic, C., Popovic-Maneski, L., & Popovic, D. (2013) · Journal of Automatic Control · doi:10.2298/jac1301013p · Cited by 28
Metadata
- Authors
- Antfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F.
- Venue
- Disability and Rehabilitation: Assistive Technology
- Publisher
- Informa UK Limited
- Published
- 2012-08-28
- Volume
- 8
- Issue
- 3
- Pages
- 249-254
- ISSN
- 1748-3107 (ISSN-L)
- 1748-3115
- OpenAlex
- W2006327366
- Cited by
- 52
- References
- 6
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers. https://app.cochat.ai/papers/10.3109/17483107.2012.713435
- The paper
- Antfolk, C., Cipriani, C., Carrozza, M. C., Balkenius, C., Björkman, A., Lundborg, G., Rosén, B., & Sebelius, F. (2013). Transfer of tactile input from an artificial hand to the forearm: experiments in amputees and able-bodied volunteers. Disability and Rehabilitation: Assistive Technology. https://doi.org/10.3109/17483107.2012.713435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.