Comparison of utilization, cost, adherence, and hypoglycemia in patients with type 2 diabetes initiating rapid-acting insulin analog with prefilled pen versus vial/syringe
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Studies examining outcomes of different insulin delivery systems are limited. The objective of this study was to compare healthcare utilization, costs, adherence, and hypoglycemia rates in patients with type 2 diabetes mellitus (T2DM) initiating rapid-acting insulin analog (RAIA) using prefilled pen versus vial/syringe. METHODS: A retrospective analysis was conducted using a US claims database (1/1/2007 to 12/31/2008). Inclusion criteria were: ≥18 years old, with T2DM, ≥12 months of continuous eligibility, and new to RAIA. Difference-in-difference analyses after propensity score matching were conducted to compare changes in outcomes from 6 months prior to and 6 months after initiating RAIA with a prefilled pen versus vial/syringe (Wilcoxon rank-sum test for costs and t-test for other outcomes). Categories of utilization and costs (2009 USD) included total and diabetes-related inpatient, outpatient, and emergency room. Adherence was measured by proportion of days covered (PDC). Hypoglycemia was identified using ICD-9-CM codes. RESULTS: Baseline characteristics were similar between the prefilled pen (n = 239) and vial/syringe (n = 590) cohorts after matching. Adherence to RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (PDC: 54.6 vs. 45.2%, p < 0.001). While the increase in diabetes-related pharmacy costs from before to after initiating RAIA was greater in the prefilled pen cohort than the vial/syringe cohort (+$900 vs. +$607, p < 0.001), the prefilled pen cohort was associated with greater reductions in the total diabetes-related costs (-$235 vs. +$61, p = 0.006) and the utilization of oral anti-hyperglycemic agents (-1.3 vs. -0.7, p = 0.016). There were no significant differences in other outcomes. LIMITATIONS: Claims databases do not provide optimal measures for adherence or T2DM severity, and only capture hypoglycemia events requiring clinical intervention. CONCLUSION: Initiating RAIA with a prefilled pen was associated with better adherence and greater reduction in total diabetes-related costs than a vial/syringe. There was no significant difference in total healthcare costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A systematic review of adherence with medications for diabetes
Cramer, J. A. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1218 · Cited by 1,203
Psychological Insulin Resistance in Patients With Type 2 Diabetes
Polonsky, W. H., Fisher, L., Guzman, S., Villa-Caballero, L., & Edelman, S. V. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2543 · Cited by 551
Validation of ICD-9-CM coding algorithm for improved identification of hypoglycemia visits
Ginde, A. A., Blanc, P. G., Lieberman, R. M., & Camargo, C. A. (2008) · BMC Endocrine Disorders · doi:10.1186/1472-6823-8-4 · Cited by 234
Martin, B. C., Wiley-Exley, E. K., Richards, S., Domino, M. E., Carey, T. S., & Sleath, B. L. (2009) · Annals of Pharmacotherapy · doi:10.1345/aph.1k671 · Cited by 226
Cited by
Davies, M. J., Gagliardino, J. J., Gray, L. J., Khunti, K., Mohan, V., & Hughes, R. (2013) · Diabetic Medicine · doi:10.1111/dme.12128 · Cited by 294
A Systematic Review of Insulin Adherence Measures in Patients with Diabetes
Stolpe, S., Kroes, M. A., Webb, N., & Wisniewski, T. (2016) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2016.22.11.1224 · Cited by 77
“…of having a PDC > 1, 4 studies reported appending days of overlap to the previous prescription’s end, where overlaps existed.49,51,53,54 In Lee et al. (2011), data on the days supply were missing and therefore, the average days supply was imputed.49 In Gibson et al. (2010), if a patient…”
BackgroundLasalvia, P., Barahona-Correa, J. E., Romero-Alvernia, D. M., Gil-Tamayo, S., Castañeda-Cardona, C., Bayona, J. G., Triana, J. J., Laserna, A. F., Mejía-Torres, M., Restrepo-Jimenez, P., et al. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816633721 · Cited by 63
“It ranges from 0 to 1, indicating null or complete adherence, respectively.13,15,23,26 Proportion of days covered (PDC) is calculated in a similar fashion to MPR.16 Four studies13,15,23,26 assessed final MPR at 12-month follow-up, and showed statistically significant difference favoring pen, but had considerable heter…”
MethodSlabaugh, S. L., Bouchard, J. R., Li, Y., Baltz, J. C., Meah, Y. A., & Moretz, D. C. (2015) · Advances in Therapy · doi:10.1007/s12325-015-0266-5 · Cited by 41
Ahmann, A., Szeinbach, S. L., Gill, J., Traylor, L., & Garg, S. K. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0172 · Cited by 39
Grabner, M., Chu, J., Raparla, S., Quimbo, R., Zhou, S., & Conoshenti, J. (2013) · Postgraduate Medicine · doi:10.3810/pgm.2013.05.2656 · Cited by 36
Adherence to insulin treatment in diabetes: can it be improved?糖尿病患者使用胰岛素治疗的依从性:它能够得到改善吗?
Doggrell, S. A., & Chan, V. (2015) · Journal of Diabetes · doi:10.1111/1753-0407.12212 · Cited by 29
Metadata
- Authors
- Lee, L. J., Li, Q., Reynolds, M. W., Pawaskar, M. D., & Corrigan, S. M.
- Venue
- Journal of Medical Economics
- Publisher
- Informa Healthcare
- Published
- 2011-01
- Volume
- 14
- Issue
- 1
- Pages
- 75-86
- ISSN
- 1369-6998 (ISSN-L)
- 1941-837X
- OpenAlex
- W2134766711
- Cited by
- 25
- References
- 4
- FWCI
- 2.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.