Cited by 110Luminescence and Fluorescent MaterialsPhotochemistry and Electron Transfer StudiesMolecular Sensors and Ion Detection

Rational Design and Application of an Indolium-Derived Heptamethine Cyanine with Record-Long Second Near-Infrared Emission

Open access
Ma, Xiaoxie, Huang, Yurou, Abedi, Syed Ali Abbas, Kim, Heejeong, Davin, Tan Teck Boon, Liu, Xiaogang, Yang, Wen-Chao, Sun, Yao +4 more·2022·CCS Chemistry

Abstract

Open AccessCCS ChemistryRESEARCH ARTICLE6 Jun 2022Rational Design and Application of an Indolium-Derived Heptamethine Cyanine with Record-Long Second Near-Infrared Emission Xiaoxie Ma†, Yurou Huang†, Syed Ali Abbas Abedi, Heejeong Kim, Tan Teck Boon Davin, Xiaogang Liu, Wen-Chao Yang, Yao Sun, Sheng Hua Liu, Jun Yin, Juyoung Yoon and Guang-Fu Yang Xiaoxie Ma† Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Yurou Huang† Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Syed Ali Abbas Abedi Fluorescence Research Group, Singapore University of Technology and Design, Singapore 487372 , Heejeong Kim Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750 , Tan Teck Boon Davin Fluorescence Research Group, Singapore University of Technology and Design, Singapore 487372 , Xiaogang Liu Fluorescence Research Group, Singapore University of Technology and Design, Singapore 487372 , Wen-Chao Yang Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Yao Sun Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Sheng Hua Liu Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Jun Yin *Corresponding authors: E-mail Address: [email protected] E-mail Address: [email protected] E-mail Address: [email protected] Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 , Juyoung Yoon *Corresponding authors: E-mail Address: [email protected] E-mail Address: [email protected] E-mail Address: [email protected] Department of Chemistry and Nano Science, Ewha Womans University, Seoul 120-750 and Guang-Fu Yang *Corresponding authors: E-mail Address: [email protected] E-mail Address: [email protected] E-mail Address: [email protected] Key Laboratory of Pesticide and Chemical Biology (Ministry of Education), Hubei International Scientific and Technological Cooperation Base of Pesticide and Green Synthesis, International Joint Research Center for Intelligent Biosensing Technology and Health, College of Chemistry, Central China Normal University, Wuhan 430079 https://doi.org/10.31635/ccschem.021.202101630 SectionsSupplemental MaterialAboutAbstractPDF ToolsAdd to favoritesDownload CitationsTrack Citations ShareFacebookTwitterLinked InEmail Heptamethine cyanine dyes, typified by indocyanine green, have been extensively employed as bioimaging indicators and theranostic agents. Significant efforts have been made to develop functional heptamethine cyanine dyes with outstanding bioimaging and theranostic utilities. In this work, we rationally designed and successfully developed a novel indolium-like heptamethine cyanine dye by installing indolium-derived polycyclic aromatic hydrocarbons on the terminal ends of a conjugated polyene backbone. This dye showed excellent photostability and showed bright fluorescent emission in the second near-infrared (NIR-II) window with a peak at approximately 1120 nm. Such long wavelength emission prompted a superior bioimaging resolution in vivo. In particular, this NIR-II dye had the remarkable capability of marking the blood vessels of the hindlimbs, abdomens, and brains of mice. More significantly, this dye involved a typical indolium-like heptamethine skeleton and exhibited two strong absorption bands in the 700–1300 nm NIR range, which endowed it with an intrinsic tumor-targeting capability and a high photothermal conversion efficiency (up to 68.2%), s

Integrity signals

Registry

Crossref · 10.31635/ccschem.021.202101630

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The contradictory properties between emission wavelength and quantum yield of organic fluorophores typically result in significantly diminished brightness for fluorophores with emission >1100 nm.

    “The contradictory properties between emission wavelength and quantum yield of organic fluorophores typically result in significantly diminished brightness for fluorophores with emission >1100 nm85,213.”

Cited by

Sorted by citations

Authors
Ma, X., Huang, Y., Abedi, S. A. A., Kim, H., Davin, T. T. B., Liu, X., Yang, W.-C., Sun, Y., Liu, S. H., Yin, J., Yoon, J., & Yang, G.-F.
Affiliations
  • Central China Normal University (CN)
  • Singapore University of Technology and Design (SG)
  • Ewha Womans University (KR)
Venue
CCS Chemistry
Published
2022-06-06
Volume
4
Issue
6
Pages
1961-1976
ISSN
2096-5745 (ISSN-L)
OpenAlex
W4200376656
Cited by
110
References
0
Citations by year
2026: 18 · 2025: 25 · 2024: 21 · 2023: 28 · 2022: 18
FWCI
5.09
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
CCS Chemistry (publishedVersion, cc-by-nc)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Photochemistry and Electron Transfer Studies
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
heptamethine cyanine, cyanine dyes, fluorescence lifetime, near-infrared fluorescence imaging, dye design, fluorescence lifetime imaging, fluorescence lifetime spectroscopy, fluorescence lifetime tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review