OBJECTIVE: The authors performed a pooled analysis of 3 studies—IntrePED (International Retrospective Study of the Pipeline Embolization Device), PUFS (Pipeline for Uncoilable or Failed Aneurysms Study), and ASPIRe (Aneurysm Study of Pipeline in an Observational Registry)—in order to assess angiographic outcomes and clinical safety of the Pipeline embolization device (PED). METHODS: IntrePED was a retrospective study, while PUFS and ASPIRe were prospective studies. For each patient included in these studies, the authors collected baseline demographic data, aneurysm characteristics, and procedural details. The primary outcomes for this combined analysis were clinical outcomes, including neurological morbidity and mortality and major ipsilateral intracranial hemorrhage and ischemic stroke. The secondary outcomes were angiographic occlusion rates, which were available for ASPIRe and PUFS only. RESULTS: A total of 1092 patients with 1221 aneurysms were included across the 3 studies. The mean aneurysm size was 12.0 ± 7.8 mm and the mean neck size was 6.6 ± 4.8 mm. The major ipsilateral ischemic stroke rate was 3.7% (40/1091). The major ipsilateral intracranial hemorrhage rate was 2.0% (22/1091). The major neurological morbidity rate was 5.7% (62/1091). The neurological mortality rate was 3.3% (36/1091). The combined major morbidity and neurological mortality rate was 7.1% (78/1091). The complete occlusion rates were 75.0% at 180 days (111/148) and 85.5% at 1 year (94/110). The overall aneurysm retreatment rate was 3.0% (33/1091) at a mean follow-up time of 10.2 ± 10.8 months. CONCLUSIONS: Endovascular treatment of intracranial aneurysms with the PED is safe and effective. Angiographic occlusion rates progressed with follow-up. Rates of stroke, hemorrhage, morbidity and mortality, and retreatment were low, especially given the fact that the aneurysms treated were generally large and wide necked.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Natural Course of Unruptured Cerebral Aneurysms in a Japanese Cohort
The UCAS Japan Investigators (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113260 · Cited by 1,530 · cited 1×
“6,13 In a series of over 150 large and giant ICA aneurysms treated with coil embolization, Chalouhi et al. noted a 12% complication rate with recurrence and retreatment rates greater than 30%.”
BackgroundPipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Becske, T., Kallmes, D. F., Saatci, I., McDougall, C. G., Szikora, I., Lanzino, G., Moran, C. J., Woo, H. H., Lopes, D. K., Berez, A. L., et al. (2013) · Radiology · doi:10.1148/radiol.13120099 · Cited by 1,108
Self-citationEndovascular Treatment of Intracranial Aneurysms With Flow Diverters: A Meta-Analysis
Brinjikji, W., Murad, M. H., Lanzino, G., Cloft, H. J., & Kallmes, D. F. (2013) · Stroke · doi:10.1161/strokeaha.112.678151 · Cited by 900
Self-citationThe Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Self-citationSaatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368 · cited 1×
“3,16 It is important to note that 3-and 5-year angiographic outcome data were only collected in PUFS.”
BackgroundBriganti, F., Napoli, M., Tortora, F., Solari, D., Bergui, M., Boccardi, E. P., Cagliari, E., Castellan, L., Causin, F., Ciceri, E. F. M., et al. (2012) · Neuroradiology · doi:10.1007/s00234-012-1047-3 · Cited by 180
Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
Arrese, I., Sarabia, R., Pintado, R., & Delgado-Rodriguez, M. (2013) · Neurosurgery · doi:10.1227/01.neu.0000430297.17961.f1 · Cited by 171
Hong, Y., Wang, Y., Deng, Z., Wu, Q., & Zhang, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0082311 · Cited by 143 · cited 1×
“9”
Coiling of Large and Giant Aneurysms: Complications and Long-Term Results of 334 Cases
Chalouhi, N., Tjoumakaris, S., Gonzalez, L. F., Dumont, A. S., Starke, R. M., Hasan, D. M., Wu, C., Singhal, S., Moukarzel, L. A., Rosenwasser, R. H., et al. (2013) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3696 · Cited by 138 · cited 2×
“6,13 In a series of over 150 large and giant ICA aneurysms treated with coil embolization, Chalouhi et al. noted a 12% complication rate with recurrence and retreatment rates greater than 30%.”
BackgroundInfluentialSelf-citationZhao, B., Yin, R. L., Lanzino, G. S., Kallmes, D. F., Cloft, H. J., & Brinjikji, W. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4834 · Cited by 127
Self-citation
Cited by
Sarrami-Foroushani, A., Lassila, T., MacRaild, M., Asquith, J., Roes, K. C. B., Byrne, J. V., & Frangi, A. F. (2021) · Nature Communications · doi:10.1038/s41467-021-23998-w · Cited by 83
Metadata
- Authors
- Kallmes, D. F., Brinjikji, W., Cekirge, S., Fiorella, D., Hanel, R. A., Jabbour, P., Lopes, D., Lylyk, P., McDougall, C. G., & Siddiqui, A.
- Venue
- Journal of Neurosurgery
- Published
- 2017-10
- Volume
- 127
- Issue
- 4
- Pages
- 775-780
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2539450140
- Cited by
- 249
- References
- 10
- FWCI
- 15.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.